The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Design and preparation of polymeric scaffolds for tissue engineering
Open accessAbstract
Polymeric scaffolds for tissue engineering can be prepared with a multitude of different techniques. Many diverse approaches have recently been under development. The adaptation of conventional preparation methods, such as electrospinning, induced phase separation of polymer solutions or porogen leaching, which were developed originally for other research areas, are described. In addition, the utilization of novel fabrication techniques, such as rapid prototyping or solid free-form procedures, with their many different methods to generate or to embody scaffold structures or the usage of self-assembly systems that mimic the properties of the extracellular matrix are also described. These methods are reviewed and evaluated with specific regard to their utility in the area of tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Controlled Degradation and Mechanical Behavior of Photopolymerized Hyaluronic Acid Networks
Burdick, J. A., Chung, C., Jia, X., Randolph, M. A., & Langer, R. (2005) · Biomacromolecules · doi:10.1021/bm049508a · Cited by 777
Hile, D. D., Amirpour, M. L., Akgerman, A., & Pishko, M. V. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00268-0 · Cited by 210
Jeong, S. I., Kim, B.-S., Lee, Y. M., Ihn, K. J., Kim, S. H., & Kim, Y. H. (2004) · Biomacromolecules · doi:10.1021/bm049921i · Cited by 182
Ang, K. C., Leong, K. F., Chua, C. K., & Chandrasekaran, M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30996 · Cited by 97
Photochemical crosslinking improves the physicochemical properties of collagen scaffolds
Chan, B. P., & So, K. ‐. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30469 · Cited by 96
Cited by
Vascularization is the key challenge in tissue engineering
Novosel, E. C., Kleinhans, C., & Kluger, P. J. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.004 · Cited by 1,062
Biodegradable polymer matrix nanocomposites for tissue engineering: A review
Armentano, I., Dottori, M., Fortunati, E., Mattioli, S., & Kenny, J. M. (2010) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2010.06.007 · Cited by 999
Synthetic polymer scaffolds for tissue engineering
Place, E. S., George, J. H., Williams, C. K., & Stevens, M. M. (2009) · Chemical Society Reviews · doi:10.1039/b811392k · Cited by 815
Reprogrammable recovery and actuation behaviour of shape-memory polymers
Lendlein, A., & Gould, O. E. C. (2019) · Nature Reviews Materials · doi:10.1038/s41578-018-0078-8 · Cited by 723
Self-citationEshraghi, S., & Das, S. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.002 · Cited by 524
Metadata
- Authors
- Weigel, T., Schinkel, G., & Lendlein, A.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2006-11
- Volume
- 3
- Issue
- 6
- Pages
- 835-851
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2145374357
- Cited by
- 228
- References
- 6
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.