Cited by 43Heat Transfer and OptimizationHeat Transfer MechanismsHeat Transfer and Numerical Methods

The DOI matches its Crossref record.

3D-CFD simulation and neural network model for the j and f factors of the wavy fin-and-flat tube heat exchangers

Open access
Khoshvaght Aliabadi, M, Gholam Samani, M, Hormozi, F, Haghighi Asl, A·2011·Brazilian Journal of Chemical Engineering

Abstract

A three dimensional (3D) computational fluid dynamics (CFD) simulation and a neural network model are presented to estimate the behaviors of the Colburn factor (j) and the Fanning friction factor (f) for wavy fin - and - flat tube (WFFT) heat exchangers. Effects of the five geometrical factors of fin pitch, fin height, fin length, fin thickness, and wavy amplitude are investigated over a wide range of Reynolds number (600<Re<7000). The CFD simulation results express that the geometrical parameters of wavy fins have significant effects on the j and f factors as a function of Reynolds number. The computational results have an adequate accuracy when compared to experimental data. The accuracy of the calculations of the j and f factors are evaluated by the values of the absolute average relative deviation (AARD), being respectively 3.8% and 8.2% for the CFD simulation and 1.3% and 1% for the neural network model. Finally, new correlations are proposed to estimate the values of the j and f factors with 3.22% and 3.68% AARD respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1590/s0104-66322011000300016

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Still being checked.

Research works printed but not linked: 20

  1. Dong J, 2007, Heat transfer and pressure drop correlations for the multi-louvered fin compact heat exchangers, Energ. Convers. Manage, 48, 1506, 10.1016/j.enconman.2006.11.023 · DOI
  2. Dong J, 2007, Heat transfer and pressure drop correlations for the wavy fin and flat tube heat exchangers, Appl. Therm. Eng, 27, 2066, 10.1016/j.applthermaleng.2006.11.012 · DOI · Paper page
  3. Dong J, 2007, Air-side thermal hydraulic performance of offset strip fin aluminum heat exchangers, Appl. Therm. Eng, 27, 306, 10.1016/j.applthermaleng.2006.08.005 · DOI · Paper page
  4. Dong J, 2010, Experimental and numerical investigation of thermal-hydraulic performance in wavy fin-and-flat tube heat exchangers, Appl. Therm. Eng, 30, 1377, 10.1016/j.applthermaleng.2010.02.027 · DOI
  5. Erek A, 2005, Effect of geometrical parameters on heat transfer and pressure drop characteristics of plate fin and tube heat exchangers, Appl. Therm. Eng, 25, 2421, 10.1016/j.applthermaleng.2004.12.019 · DOI
  6. Huzayyin A. S, 2007, Air-side performance of a wavy-finned-tube direct expansion cooling and dehumidifying air coil, Int. J. Refrig, 30, 230, 10.1016/j.ijrefrig.2006.07.023 · DOI
  7. Leu J. S, 2004, Heat transfer and fluid flow analysis in plate-fin and tube heat exchangers with a pair of block shape vortex generators, Int. J. Heat Mass Tran, 47, 4327, 10.1016/j.ijheatmasstransfer.2004.04.031 · DOI
  8. Manglik R. M, 2005, Low Reynolds number forced convection in three-dimensional wavy-plate-fin compact channels: fin density effects, Int. J. Heat Mass Tran, 48, 1439, 10.1016/j.ijheatmasstransfer.2004.10.022 · DOI
  9. Metwally H. M, 2004, Enhanced heat transfer due to curvature-induced lateral vortices in laminar flows in sinusoidal corrugated-plate channels, Int. J. Heat Mass Tran, 47, 2283, 10.1016/j.ijheatmasstransfer.2003.11.019 · DOI
  10. Pirompugd W, 2006, Simultaneous heat and mass transfer characteristics for wavy fin-and-tube heat exchangers under dehumidifying conditions, Int. J. Heat Mass Tran, 49, 132, 10.1016/j.ijheatmasstransfer.2005.05.043 · DOI
  11. Şahin H. M, 2007, 3-D Numerical study on the correlation between variable inclined fin angles and thermal behavior in plate fin-tube heat exchanger, Appl. Therm. Eng, 27, 1806, 10.1016/j.applthermaleng.2007.01.011 · DOI
  12. Tao Y. B, 2007, Three-dimensional numerical study of wavy fin-and-tube heat exchangers and field synergy principle analysis, Int. J. Heat Mass Tran, 59, 1163, 10.1016/j.ijheatmasstransfer.2006.03.019 · DOI
  13. Tian L, 2009, A comparative study on the air-side performance of wavy finand-tube heat exchanger with punched delta winglets in staggered and in-line arrangements, Int. J. Therm. Sci, 48, 1765, 10.1016/j.ijthermalsci.2009.02.007 · DOI
  14. Wang C. C, 2002, Empirical correlations for heat transfer and flow friction characteristics of herringbone wavy fin-and-tube heat exchangers, Int. J. Refrig, 25, 673, 10.1016/S0140-7007(01)00049-4 · DOI
  15. Wena M. Y, 2009, Heat-transfer enhancement in fin-and-tube heat exchanger with improved fin design, Appl. Therm. Eng, 29, 1050, 10.1016/j.applthermaleng.2008.05.019 · DOI
  16. Wongwises S, 2005, Effect of fin pitch and number of tube rows on the air side performance of herringbone wavy fin and tube heat exchangers, Energ. Convers. Manage, 46, 2216, 10.1016/j.enconman.2004.09.011 · DOI
  17. Xie G, 2009, Parametric study and multiple correlations on air-side heat transfer and friction characteristics of fin-and-tube heat exchangers with large number of large-diameter tube rows, Appl. Therm. Eng, 29, 1, 10.1016/j.applthermaleng.2008.01.014 · DOI · Paper page
  18. Yan W. M, 2000, Heat transfer and friction characteristics of fin-and-tube heat exchangers, Int. J. Heat Mass Tran, 43, 1651, 10.1016/S0017-9310(99)00229-X · DOI · Paper page
  19. Zhang J, 2004, Effect of fin waviness and spacing on the lateral vortex structure and laminar heat transfer in wavy-platefin cores, Int. J. Heat Mass Tran, 47, 1719, 10.1016/j.ijheatmasstransfer.2003.10.006 · DOI · Paper page
  20. Zhu Y, 2008, Three-Dimensional Numerical Simulation on the Laminar Flow and Heat Transfer in Four Basic Fins of Plate-Fin Heat Exchangers, J. Heat. Tran, 130, 111801, 10.1115/1.2970072 · DOI

Cited by

Sorted by citations

Metadata

Authors
Khoshvaght Aliabadi, M., Gholam Samani, M., Hormozi, F., & Haghighi Asl, A.
Affiliations
  • Semnan University, I. R. Iran
  • Semnan University (IR)
Venue
Brazilian Journal of Chemical Engineering
Published
2011-09
Volume
28
Issue
3
Pages
505-520
ISSN
0104-6632 (ISSN-L)
OpenAlex
W2128724404
Cited by
43
References
0
Citations by year
2026: 3 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 5 · 2013: 3
FWCI
4.54
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Brazilian Journal of Chemical Engineering (publishedVersion, cc-by-nc)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, other-oa)
  • Americanae (AECID Library) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
  • Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
Keywords
Colburn factor, Fanning friction factor, fin spacing, fin height, fin length, fin thickness, Reynolds number effects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review