A simple automated procedure for thiol measurement in human serum samples
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Thiol groups have been described as the main responsible for antioxidative effects of plasmatic proteins. Also, thiol serum levels have shown a positive correlation with total antioxidant capacity (TAC) in many studies. Measurement of TAC by substract oxidation-based methods have been widely used as a reference to measure antioxidant status; however, in many cases these methods are inexact or imprecise, usually when performed by manual procedures. In this paper we describe a simple automated procedure for the determination of total thiols in serum, which was based on Ellman’s method. It was correlated with several markers of oxidative/antioxidative status, such as TAC and thiobarbituric acid reactive substance test (TBARs). Serum thiol levels were correlated positively with TAC (r = 0.298, p < 0.001) and negatively with TBARs levels (r = -0.330, p < 0.001). The novel automated procedure for thiol groups measurement can be a great tool in estimation of antioxidant status together with TAC assay. This procedure makes the determination of total thiol groups in large scale possible in clinical chemistry or research laboratories where this approach is necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidants, antioxidants, and the degenerative diseases of aging.
Ames, B. N., Shigenaga, M. K., & Hagen, T. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.17.7915 · Cited by 5,958
Halliwell, B., & Whiteman, M. (2004) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0705776 · Cited by 2,238
Cited by
Campos, F. C., Victorino, V. J., Martins-Pinge, M. C., Cecchini, A. L., Panis, C., & Cecchini, R. (2014) · Food and Chemical Toxicology · doi:10.1016/j.fct.2014.03.013 · Cited by 53
“Plasmatic lipid hydroperoxides concentrations were estimated by FOX method with modifications (Costa et al., 2006; Gay et al., 2002).”
MethodDeminice, R., Rosa, F. T., Franco, G. S., da Cunha, S. F. C., de Freitas, E. C., & Jordao, A. A. (2014) · European Journal of Nutrition · doi:10.1007/s00394-013-0636-1 · Cited by 20
Deminice, R., & Jordao, A. A. (2016) · Redox Report · doi:10.1179/1351000215y.0000000020 · Cited by 12
Barreto, L. P., de Oliveira Silva, R. Y., de Almeida, B. B., Ovídio, P. P., & Jordao, A. A. (2023) · Gene Expression · doi:10.14218/ge.2022.00006 · Cited by 4
Metadata
- Authors
- Costa, C. M. D., Santos, R. C. C. D., & Lima, E. S.
- Venue
- Jornal Brasileiro de Patologia e Medicina Laboratorial
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2006-10
- Volume
- 42
- Issue
- 5
- ISSN
- 1676-2444 (ISSN-L)
- OpenAlex
- W2000429341
- Cited by
- 146
- References
- 2
- FWCI
- 0.20
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple automated procedure for thiol measurement in human serum samples. https://app.cochat.ai/papers/10.1590/s1676-24442006000500006
- The paper
- Costa, C. M. D., Santos, R. C. C. D., & Lima, E. S. (2006). A simple automated procedure for thiol measurement in human serum samples. Jornal Brasileiro de Patologia e Medicina Laboratorial. https://doi.org/10.1590/s1676-24442006000500006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.