HEAT TRANSFER AND FRICTION CORRELATIONS FOR PLATE FINNED-TUBE HEAT EXCHANGERS HAVING PLAIN FINS
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The predictive ability of the friction factors of McQuiston's correlation was quite poor.
“However, the predictive ability of the friction factors, as pointed out by Gray and Webb [3], was quite poor.”
From Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation (2000) · cites this paper as [3]
The Gray and Webb [3] correlation significantly improved the predictive capability of friction factors, and its heat transfer correlation is comparable to that of McQuiston [2].
“The Gray and Webb [3] correlation had significantly improved the predictive capability of friction factors, and the heat transfer correlation is comparable to that of McQuiston [2].”
From Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation (2000) · cites this paper as [3]
The Gray and Webb [3] correlation is more appropriate for larger diameter tube and more number of tube rows owing to its limitation of database.
“However, it should be pointed out that the correlation developed by Gray and Webb [3] is more appropriate for larger diameter tube and more number of tube rows owing to its limitation of database.”
From Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation (2000) · cites this paper as [3]
The Gray and Webb correlation [3] considerably underpredicts the heat transfer data for those having smaller tube diameter.
“A recent investigation by Wang et al. [4] indicated that the Gray and Webb correlation [3] considerably underpredicts the heat transfer data for those having smaller tube diameter.”
From Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation (2000) · cites this paper as [3]
The mean deviation of the heat transfer correlation for the Gray and Webb correlation is 15.8%.
“As seen, the mean deviation of heat transfer correlation for the McQuiston correlation, the Gray and Webb correlation, and the Seshimo and Fujii correlation [6] are 34.4, 15.8, and 11.3%, respectively.”
From Heat transfer and friction characteristics of plain fin-and-tube heat exchangers, part II: Correlation (2000) · cites this paper as [3]
The airside heat transfer coefficient ha is a function of mass velocity, tube and row spacings, fin spacing, tube diameter, and number of tube rows.
“The airside heat transfer coefficient ha, is a function of the mass velocity G, tube and row spacings S, and W, fin spacing S, tube diameter D, and number of tube rows N. The following expression was adapted from Gray and Webb10:”
From Performance of finned-tube heat exchangers under frosting conditions: I. Simulation model (1993) · cites this paper as [10]
Cited by
Sorted by citations
Wang, C.-C., Chi, K.-Y., & Chang, C.-J. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00333-6 · Cited by 464 · see citing works
Wang, C.-C., & Chi, K.-Y. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00332-4 · Cited by 274 · see citing works
Heat transfer and friction characteristics of typical wavy fin-and-tube heat exchangers
Wang, C.-C., Fu, W.-L., & Chang, C. (1997) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(96)00056-8 · Cited by 243 · see citing works
Sensible heat and friction characteristics of plate fin-and-tube heat exchangers having plane fins
Wang, C.-C., Chang, Y.-J., Hsieh, Y.-C., & Lin, Y.-T. (1996) · International Journal of Refrigeration · doi:10.1016/0140-7007(96)00021-7 · Cited by 217 · see citing works
Xie, G., Wang, Q., & Sunden, B. (2009) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.01.014 · Cited by 165 · see citing works
Bhuiyan, A., & Islam, A. K. M. S. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.05.022 · Cited by 141 · see citing works
Heat and mass transfer for plate fin-and-tube heat exchangers, with and without hydrophilic coating
Wang, C.-C., & Chang, C. T. (1998) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00060-x · Cited by 138 · see citing works
Kim, N.-H., Youn, B., & Webb, R. (1999) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2826030 · Cited by 136 · see citing works
Self-citationWang, C.-C., Lo, J., Lin, Y.-T., & Wei, C.-S. (2002) · doi:10.1016/s0017-9310(02)00085-6 · Cited by 133
Corrosion and scaling as interrelated phenomena in an operating geothermal power plant
Mundhenk, N., Huttenloch, P., Sanjuan, B., Kohl, T., Steger, H., & Zorn, R. (2013) · doi:10.1016/j.corsci.2013.01.003 · Cited by 126
An investigation of the airside performance of the slit fin-and-tube heat exchangers.
Wang, C.-C., Tao, W., & Chang, C.-J. (1999) · International Journal of Refrigeration · doi:10.1016/s0140-7007(99)00031-6 · Cited by 120 · see citing works
Tahseen, T. A., Ishak, M., & Rahman, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.070 · Cited by 115 · see citing works
Heat Rate Predictions in Humid Air-Water Heat Exchangers Using Correlations and Neural Networks
Pacheco-Vega, A., Díaz, G., Sen, M., Yang, K.-T., & McClain, R. L. (2001) · doi:10.1115/1.1351167 · Cited by 106
HEAT TRANSFER AND FRICTION CORRELATIONS FOR WAVY PLATE FIN-AND-TUBE HEAT EXCHANGERS
Kim, N.-H., Yun, J.-H., & Webb, R. (1996) · doi:10.1115/1.2824141 · Cited by 94
Self-citationLu, C.-W., Huang, J.-M., Nien, W., & Wang, C.-C. (2011) · doi:10.1016/j.enconman.2010.10.026 · Cited by 84
“Based on the previously published data, Gray and Webb [5] developed a correlation to correlate the existing experimental data.”
Tang, L., Min, Z., Xie, G., & Wang, Q.-W. (2009) · doi:10.1080/01457630802304253 · Cited by 76
Performance characteristics correlation for round tube and plate finned heat exchangers
Madi, M., Johns, R. A., & Heikal, M. (1998) · International Journal of Refrigeration · doi:10.1016/s0140-7007(98)00031-0 · Cited by 76 · see citing works
Mirth, D., & Ramadhyani, S. (1994) · Experimental Heat Transfer · doi:10.1080/08916159408946477 · Cited by 73 · see citing works
Bensafi, A., Borg, S., & Parent, D. (1997) · doi:10.1016/s0140-7007(96)00052-7 · Cited by 66
Modelling of plate finned tube evaporators and condensers working with R134A
Corberán, J., & Melón, M. G. (1998) · International Journal of Refrigeration · doi:10.1016/s0140-7007(97)00087-x · Cited by 63 · see citing works
Heat transfer characterization of flat plain fins and round tube heat exchangers
Kayansayan, N. (1993) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(93)90067-s · Cited by 59 · see citing works
“However, as noted by Webb [16], the small influence of fin spacing, especially at high flow rates, is probably misleading.”
BackgroundMethodA new procedure for performance prediction of air conditioning coils
Vardhan, A., & Dhar, P. (1998) · doi:10.1016/s0140-7007(97)00020-0 · Cited by 57
“(3) The total air flow rate is assumed to be equally divided among the nodes in the face area of the coil.”
BackgroundPerformance of finned-tube heat exchangers under frosting conditions: I. Simulation model
Kondepudi, S. N., & O'Neal, D. L. (1993) · International Journal of Refrigeration · doi:10.1016/0140-7007(93)90045-a · Cited by 54 · see citing works
Pacheco-Vega, A., Sen, M., & Yang, K.-T. (2003) · doi:10.1016/s0017-9310(02)00365-4 · Cited by 50
“• Four unknowns: Gray and Webb [17] and Kim et al.”
BackgroundMethodResultInfluentialDomanski, P. (1989) · doi:10.6028/nist.ir.89-4133 · Cited by 49
“To calculate an average value for the j-factor for heat exchangers with less than four depth rows, jN (where N<4) , Gray and Webb [11] provided the following equation:”
BackgroundMethodKhartabil, H., & Christensen, R. (1992) · doi:10.1016/0894-1777(92)90125-o · Cited by 42
Wu, X., Lin, Z.-M., Liu, S., Su, M., Wang, L.-C., & Wang, L.-C. (2017) · doi:10.1016/j.applthermaleng.2017.03.072 · Cited by 41
A heat exchanger model for mixtures and pure refrigerant cycle simulations
Judge, J., & Radermacher, R. (1997) · doi:10.1016/s0140-7007(97)00010-8 · Cited by 41
Variable-speed heat pump model for a wide range of cooling conditions and loads
Zakula, T., Gayeski, N. T., Armstrong, P., & Norford, L. (2011) · HVAC&R Research · doi:10.1080/10789669.2011.607745 · Cited by 38
Lee, J., & Domanski, P. (1997) · doi:10.2172/513508 · Cited by 37 · see citing works
Lee, J.-H., Kwon, Y.-C., & Kim, M. (2003) · doi:10.1016/s0140-7007(03)00023-9 · Cited by 36
“Heat transfer coefficient Air-side Gray and Webb [6,7]”
BackgroundMethodHEAT TRANSFER AND FRICTION CHARACTERISTICS OF CONVEX-LOUVER FIN-AND-TUBE HEAT EXCHANGERS
Wang, C.-C., Chen, P.-Y., & Jang, J. (1996) · Experimental Heat Transfer · doi:10.1080/08916159608946514 · Cited by 36 · see citing works
Salameh, T., Alkhalidi, A., Rabaia, M. K. H., Swailmeen, Y. A., Alroujmah, W., Ibrahim, M., & Abdelkareem, M. (2022) · Renewable Energy · doi:10.1016/j.renene.2022.07.121 · Cited by 34 · see citing works
Performance simulation of combined heat pump with unglazed transpired solar collector
Safijahanshahi, E., & Salmanzadeh, M. (2019) · Solar Energy · doi:10.1016/j.solener.2019.01.038 · Cited by 31
Longo, G., Righetti, G., Zilio, C., & Bertolo, F. (2014) · doi:10.1016/j.applthermaleng.2014.01.023 · Cited by 31
Design of Plate-Fin Tube Dehumidifiers for Humidification–Dehumidification Desalination Systems
Sievers, M., & Lienhard, J., V (2013) · doi:10.1080/01457632.2014.916153 · Cited by 31
“Gray and Webb’s j-factor equation [40] is also published in reference [43].”
BackgroundMethodInfluentialPaeng, J., Kim, K. H., & Yoon, Y. (2009) · doi:10.1007/s12206-008-1013-5 · Cited by 31
Jiang, Y.-L., Zhang, H., Wang, Y.-M., Wang, Y.-R., Liu, M.-Z., You, S.-J., Wu, Z.-X., Fan, M., & Wei, S. (2022) · Energy · doi:10.1016/j.energy.2022.123398 · Cited by 30
An analytical correlation for conjugate heat transfer in fin and tube heat exchangers
Kalantari, H., Ghoreishi-Madiseh, S., Kurnia, J. C., & Sasmito, A. (2021) · doi:10.1016/j.ijthermalsci.2021.106915 · Cited by 30
Analysis of Convective Thermal Resistance in Ducted Fan-Heat Sinks
Kim, S., & Webb, R. (2006) · IEEE transactions on components and packaging technologies · doi:10.1109/tcapt.2006.880522 · Cited by 29
“Webb [11 Ch.3] provides quantitative “performance evaluation criteria” to compare the performance of enhanced versus plate fin geometries for different operating conditions and constraints.”
MethodInfluentialSelf-citationHeat transfer characterization of plate fin-tube heat exchangers
Kayansayan, N. (1993) · doi:10.1016/0890-4332(93)90026-r · Cited by 26
Obtaining Closure for Fin-and-Tube Heat Exchanger Modeling Based on Volume Averaging Theory (VAT)
Zhou, F., Hansen, N., Geb, D., & Catton, I. (2011) · doi:10.1115/1.4004393 · Cited by 25
“Based on a superposition model, which was initially proposed by Rich [6], Gray and Webb [7] gave an updated correlation for fin-and-tube heat exchangers, that is, superior to McQuiston’s [5].”
MethodBozkula, G., & Demir, H. (2022) · International journal of thermal sciences · doi:10.1016/j.ijthermalsci.2022.107580 · Cited by 24
Batista, J., Trp, A., & Lenic, K. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118528 · Cited by 24
Tian, X.-H., Jin, H., Song, K.-W., Wang, L.-C., Liu, S., & Wang, L.-C. (2018) · Experimental Heat Transfer · doi:10.1080/08916152.2017.1410503 · Cited by 23 · see citing works
Oliet, C., Perez-Segarra, C., Danov, S., & Oliva, A. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.02.005 · Cited by 22 · see citing works
Siddiqui, M., Azam, M. A., & Ali, H. (2022) · The Arabian journal for science and engineering · doi:10.1007/s13369-022-06832-3 · Cited by 21
“Grey andWebb [33] heat transfer correlation was the datum by which the confidence intervals were evaluated with low root mean square values in prediction of dry bulb temperature and humidity at the coil exit.”
MethodExperimental and theoretical performance analysis of air-cooled plate-finned-tube evaporators
Horuz, I., Kurem, E., & Yamankaradeniz, R. (1998) · doi:10.1016/s0735-1933(98)00065-7 · Cited by 21
Inlow, S., & Groll, E. (1996) · doi:10.1080/10789669.1996.10391337 · Cited by 21
Kumar, A., Joshi, J., Nayak, A., & Vijayan, P. (2015) · doi:10.1007/s12046-015-0362-x · Cited by 19
“The results were compared with the results of the Kays & London (1955), Wang et al (2000), Gray & Webb (1986), and Kim et al (1999).”
ResultFluid Flow and Heat Transfer in Plate-Fin and Tube Heat Exchangers in a Transitional Flow Regime
Zhang, L.-Z., Zhong, W., Chen, J.-M., & Zhou, J. (2011) · doi:10.1080/10407782.2011.627802 · Cited by 19
Numerical analysis of evaporation performance in a finned-tube heat exchanger
Byun, J.-S., Lee, J.-H., & Choi, J.-Y. (2007) · doi:10.1016/j.ijrefrig.2006.12.002 · Cited by 17
On the Airside Performance of Fin-and-Tube Heat Exchangers
Wang, C.-C. (1999) · Springer eBooks · doi:10.1007/978-94-015-9159-1_9 · Cited by 17 · see citing works
Zhou, F., Hansen, N., Geb, D., & Catton, I. (2011) · doi:10.1115/1.4004478 · Cited by 16
“Based on a superposition model which was initially proposed by Rich [10], Gray and Webb [11] gave an updated correlation for fin-and-tube heat exchangers that is superior to McQuiston’s [9].”
MethodStignor, C. H., Sundén, B., & Fahlen, P. (2007) · doi:10.1016/j.ijrefrig.2007.02.007 · Cited by 15
“Such criteria are outlined by Bergles [9] and for low Reynolds number flow in particular by Webb and Bergles [42].”
MethodThermal performance of a single-row fin-and-tube heat exchanger
Tang, S.-P., & Yang, K.-T. (2005) · doi:10.1007/s11630-005-0029-8 · Cited by 15
Liu, S., Jin, H., Song, K.-W., Wang, L.-C., Wu, X., & Wang, L.-C. (2017) · Heat and Mass Transfer · doi:10.1007/s00231-017-2044-1 · Cited by 13
“The experimental results of Nu for the plain fin with 4 tube rows are compared with the well-known correlation of Gray [26], and the experimental results of f are compared with the well-known correlation of Wang (14) m = √”
MethodInfluentialChe, M.-C., & Elbel, S. (2021) · doi:10.1016/j.ijrefrig.2021.06.012 · Cited by 12
Experimental validation of model predictions on evaporator coils with an emphasis on fin efficiency
Liang, S.-Y., & Wong, T. (2010) · doi:10.1016/j.ijthermalsci.2009.08.004 · Cited by 12
Heat Pipe Finned Heat Exchanger for Heat Recovery: Experimental Results and Modeling
Righetti, G., Zilio, C., Mancin, S., & Longo, G. (2018) · doi:10.1080/01457632.2017.1358483 · Cited by 11
Linking objective and subjective modeling in engineering design through arc-elastic dominance
Sébastian, P., Ledoux, Y., Collignan, A., & Pailhès, J. (2012) · Expert systems with applications · doi:10.1016/j.eswa.2012.01.079 · Cited by 11
“It must be noted that: The friction factors and heat transfer coefficients of the air inside the tube and fin exchangers are based on Gray and Webb’s model (Gray & Webb, 1986) and corroborated from data provided by the company that manufactures the exchangers.”
MethodHeat Transfer Simulation and Structural Optimization of Spiral Fin-and-Tube Heat Exchanger
Jiang, H., Jiang, T.-T., Tian, H., Wu, Q., Deng, C.-Y., & Zhang, R. (2024) · Electronics · doi:10.3390/electronics13234639 · Cited by 10
“Subsequently, researchers such as McQuis-ton [4], Gray [5], and Webb [5] further expanded their theoretical research based on this foundation.”
Soft Computing Applications in Thermal Energy Systems
Pacheco-Vega, A. (2011) · Soft Computing in Green and Renewable Energy Systems · doi:10.1007/978-3-642-22176-7_1 · Cited by 10
A sequential approach for achieving separate sensible and latent cooling
Ma, J., & Horton, W. (2020) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2020.04.004 · Cited by 8
The ORNL Modulating Heat Pump Design Tool -- Mark IV User's Guide
Rice, C. K. (2001) · doi:10.2172/814355 · Cited by 8
“A major update of air-side heat transfer and pressure drop calculations was completed for improved prediction for modulating air flows based on work by Gray and Webb (1986). Other heat exchanger modeling improvements included the addition of augmentation treatments of wavy and louvered surfaces dependent on Reynolds n…”
MethodMyong, J.-H., Choi, B.-N., Go, M.-G., & Kim, N.-H. (2021) · Experimental heat transfer · doi:10.1080/08916152.2021.1906357 · Cited by 7
Camaraza‐Medina, Y., Rubio-Gonzale, Á. M., Cruz-Fonticiella, O., Garcia-Morales, O. F., Toledo, R., & Quiza-Sardiñas, R. (2018) · Mathematical Modelling of Engineering Problems · doi:10.18280/mmep.050413 · Cited by 7
“Gray and Webb Correlations [13] is applicable for 5 10 47 .”
BackgroundMethodInfluentialThe effect of evaporator operating parameters on the flow patterns inside horizontal pipes
Tong, L.-G., Li, H.-Y., Wang, L., Sun, X., & Xie, Y. (2011) · doi:10.1007/s11630-011-0477-2 · Cited by 7
Maheswaran, U., Sekhar, S. C., Tham, K., & Cheong, K. W. (2006) · doi:10.1080/10789669.2006.10391211 · Cited by 7
Design Considerations for Air-Conditioning Evaporator and Condenser Coils
Pate, M. (1988) · doi:10.1007/978-94-009-2790-2_28 · Cited by 7
Performance study of finned tube evaporative air cooler based on experiment and numerical simulation
Zhang, Q., Wang, X., Ruan, W., Chen, Q.-Z., & Liu, Z.-L. (2018) · Numerical Heat Transfer, Part A Applications · doi:10.1080/10407782.2018.1490555 · Cited by 6
Domanski, P., & Payne, W. V. (2002) · doi:10.2172/808637 · Cited by 6
“Hence, his correlations do not have the ambiguity of the previously used flat-fin correlation by Gray and Webb (1986) developed using data on 16 heat exchangers, 10 of which had no fin-to-collar heat transfer resistance due to a metallurgical bond.”
MethodInfluentialAir-cooled absorbers for extreme-ambient absorption heat pumps
Garimella, S., Forinash, D. M., & Boman, D. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.08.023 · Cited by 5 · see citing works
Zheng, F., Liu, S., Lin, Z.-M., Nugud, J., Wang, L.-C., Chang, L., & Wang, L.-C. (2018) · doi:10.1115/1.4038419 · Cited by 5
Popović, P. (1999) · doi:10.31274/rtd-180813-13744 · Cited by 5
“Gray and Webb (1986) derived a general correlation for a plate heat exchanger with plain fins as they combined data fi-om several sources:”
BackgroundSarraf, D. B. (2006) · doi:10.4271/2006-01-2163 · Cited by 4
A study on airside performance of geometry combination fins using large scale model
Byun, J.-S., Lee, J.-H., Jeon, C.-D., & Mok, J.-H. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.12.016 · Cited by 3 · see citing works
Ryan, A., & Timoney, D. (1997) · doi:10.4271/970831 · Cited by 3
Jeong, J., Park, S., Sarker, D., & Chang, K. (2012) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-012-0204-2 · Cited by 2
“The air-side heat transfer coefficient of an evaporator can be estimated by Gary and Webb’s [35] correlation, which was developed based on experimental data for fintube heat exchangers having plain fins and more than 4-row tube bundles.”
MethodCFD-Based Approach to Propose a Zigzag-Shaped Tube Heat Exchanger without Fins
Rayhan, S., Kariya, K., & Miyara, A. (2023) · Thermo · doi:10.3390/thermo3020019 · Cited by 2 · see citing works
“McQuiston [18] proposed the first correlation of this application in 1978, which was later improved by Gray and Webb [19].”
MethodKim, N.-H. (2021) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-021-0940-2 · Cited by 2
Single-phase heat transfer correlation based on minimum variance
Leng, X.-L., & Li, W. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.11.046 · Cited by 2 · see citing works
Kim, N.-H. (2015) · 설비공학논문집 · doi:10.6110/kjacr.2015.27.5.254 · Cited by 2 · see citing works
“(7) 이 예측은 j와 f 상관식을 통해서도 확인할 수 있는데 Gray and Webb(8)의 평판 핀 j 인자 상관식은 (Pl/Pt)-0.502에 비례하고 Kim et al.(9)의 평판 핀 f 인자 상 관식은(Pl/Pt)-0.106에 비례한다.”
Dirbude, S., Khalifa, N., & Chandra, L. (2018) · doi:10.1007/978-981-10-4576-9_9 · Cited by 2
Biomass-driven adsorption chiller for off-grid food storage
Lockyear, K. T., Crystal, R. V., Agarwal, A., & Garimella, S. (2026) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2026.133008 · Cited by 1 · see citing works
Algorithmic performance-data classification of condensing heat exchangers
Pacheco-Vega, A., & Avila, G. (2021) · doi:10.1080/10407782.2020.1814596 · Cited by 1
Pisano, A., Martínez-Ballester, S., Corberán, J., Monpeán, F. H., Gómez, F. I., & Cascales, J. G. (2015) · doi:10.1080/23744731.2015.1040341 · Cited by 1
Investigation of Conjugate Heat Transfer in a Fin-and-Tube Heat Exchanger
Kadja, M., & Mebrouk, R. (2014) · doi:10.1115/imece2014-39546 · Cited by 1
“[6] Webb, R.L. and Gray, D.L., 1986, " Heat transfer and friction correlations for plate finned tube heat exchangers having plain fins", Proceedings of 8th Heat transfer Conference, pp. 2745-2750.”
MethodModeling of Automotive A/C Evaporators
Melón, M. G., Corberán, J., Gonzálvez, J., Quera, M., González, I., & Desille, C. (2002) · doi:10.4271/2002-01-1287 · Cited by 1
Novel geometries for air-cooled condensation of ammonia-water mixtures
Chakraborty, S., Kini, G., & Garimella, S. (2021) · doi:10.1016/j.ijrefrig.2020.10.010 · Cited by 1
Oehme, F. (2015) · doi:10.24405/524 · Cited by 1
“Gray und Webb Gray und Webb [20] entwickelten folgende Korrelation zur Berechnung des Wärmeübergangs bei Rohrrippenwärmeübertragern mit vier Rohren und glatten, trockenen Rippen:”
BackgroundInfluentialCost Minimization for Hot Gas Defrost System
Dansilasirithavorn, J. (2009) · doi:10.15368/theses.2009.91 · Cited by 1 · see citing works
Bae, K., Cha, D.-A., & Kwon, O. (2016) · Heat and Mass Transfer · doi:10.1007/s00231-016-1754-0
“The average deviation of the j-factor and pressure drop data is 9.8 and 12.7 %, respectively, compared with the correlation of Gray and Webb [14].”
ResultInfluentialFlow and heat transfer enhancement in tube heat exchangers
Ahmed, S. E. S. S., Mesalhy, O., & Abdelatief, M. A. (2015) · Heat and Mass Transfer · doi:10.1007/s00231-015-1669-1
“Webb [126] presented an excellent survey for overall heat transfer and ∆P correlations on annular-finned tubes bundles.”
BackgroundInfluentialMu, L.-B., Lu, J.-H., Wang, S.-L., Liu, G.-C., Chen, H.-B., Zhang, M.-G., Yan, J.-C., & Jiang, Y.-W. (2027) · International journal of thermal sciences · doi:10.1016/j.ijthermalsci.2026.111394
Cottier, F., Beck, O., Wanzek, S., & Jäppelt, B. (2025) · European Conference on Turbomachinery Fluid Dynamics and Thermodynamics · doi:10.29008/etc2025-102
“Additional correlations numerically developed for heat exchanger with fins are presented by Webb [3].”
Jadhav, N. P., Raja, V. K. B., & Bhosale, S. (2019) · Techno-Societal 2018 · doi:10.1007/978-3-030-16962-6_17
- Authors
- Gray, D. L., & Webb, R. L.
- Affiliations
- Pennsylvania State University (US)
- ORCID
- Gray, D. L.
- Venue
- Proceeding of International Heat Transfer Conference 8
- Publisher
- Begellhouse
- Published
- 1986
- Pages
- 2745-2750
- OpenAlex
- W2935931434
- Cited by
- 118
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 6 · 2021: 4 · 2020: 5 · 2019: 2 · 2018: 3 · 2017: 6 · 2016: 2 · 2015: 3 · 2014: 4 · 2013: 1 · 2012: 4
- FWCI
- 3.10
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Heat Transfer Conference (IHTC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- plain fins, heat transfer correlations, friction factor correlation, heat exchanger performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review