The DOI matches its Crossref record.
Finding Fluorescent Needles in the Cardiac Haystack: Tracking Human Mesenchymal Stem Cells Labeled with Quantum Dots for Quantitative In Vivo Three-Dimensional Fluorescence Analysis
Abstract
Stem cells show promise for repair of damaged cardiac tissue. Little is known with certainty, however, about the distribution of these cells once introduced in vivo. Previous attempts at tracking delivered stem cells have been hampered by the autofluorescence of host tissue and limitations of existing labeling techniques. We have developed a novel loading approach to stably label human mesenchymal stem cells with quantum dot (QD) nanoparticles. We report the optimization and validation of this long-term tracking technique and highlight several important biological applications by delivering labeled cells to the mammalian heart. The bright QD crystals illuminate exogenous stem cells in histologic sections for at least 8 weeks following delivery and permit, for the first time, the complete three-dimensional reconstruction of the locations of all stem cells following injection into the heart. Disclosure of potential conflicts of interest is found at the end of this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioconjugated quantum dots for in vivo molecular and cellular imaging☆
SMITH, A., DUAN, H., MOHS, A., & NIE, S. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.015 · Cited by 1,193
Quantum dots: bright and versatile in vitro and in vivo fluorescence imaging biosensors
Wegner, K. D., & Hildebrandt, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00532e · Cited by 984
Shrinkage-mediated imaging of entire organs and organisms using uDISCO
Pan, C., Cai, R., Quacquarelli, F. P., Ghasemigharagoz, A., Lourbopoulos, A., Matryba, P., Plesnila, N., Dichgans, M., Hellal, F., & Ertürk, A. (2016) · Nature Methods · doi:10.1038/nmeth.3964 · Cited by 602
Meta-analysis of cellular toxicity for cadmium-containing quantum dots
Oh, E., Liu, R., Nel, A., Gemill, K. B., Bilal, M., Cohen, Y., & Medintz, I. L. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.338 · Cited by 502
Kievit, F. M., & Zhang, M. (2011) · Advanced Materials · doi:10.1002/adma.201102313 · Cited by 496
Assessment and Optimization of Cell Engraftment After Transplantation Into the Heart
Terrovitis, J. V., Smith, R. R., & Marbán, E. (2010) · Circulation Research · doi:10.1161/circresaha.109.208991 · Cited by 331
Wu, T.-J., Tzeng, Y.-K., Chang, W.-W., Cheng, C.-A., Kuo, Y., Chien, C.-H., Chang, H.-C., & Yu, J. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.147 · Cited by 261
Quantum Dots for Cancer Diagnosis and Therapy: Biological and Clinical Perspectives
Zhang, H., Yee, D., & Wang, C. (2008) · Nanomedicine · doi:10.2217/17435889.3.1.83 · Cited by 260
Tracking transplanted cells in live animal using upconversion fluorescent nanoparticles
Idris, N. M., Li, Z., Ye, L., Wei Sim, E. K., Mahendran, R., Ho, P. C.-L., & Zhang, Y. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.062 · Cited by 254
Zhang, B., Yan, W., Zhu, Y., Yang, W., Le, W., Chen, B., Zhu, R., & Cheng, L. (2018) · Advanced Materials · doi:10.1002/adma.201705694 · Cited by 113
Standardization of Models and Methods Used to Assess Nanoparticles in Cardiovascular Applications
Fitzgerald, K. T., Holladay, C. A., McCarthy, C., Power, K. A., Pandit, A., & Gallagher, W. M. (2011) · Small · doi:10.1002/smll.201001347 · Cited by 26
Metadata
- Authors
- Rosen, A. B., Kelly, D. J., Schuldt, A. J. T., Lu, J., Potapova, I. A., Doronin, S. V., Robichaud, K. J., Robinson, R. B., Rosen, M. R., Brink, P. R., Gaudette, G. R., & Cohen, I. S.
- Venue
- Stem Cells
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-10
- Volume
- 25
- Issue
- 8
- Pages
- 2128-2138
- ISSN
- 1066-5099 (ISSN-L)
- 1549-4918
- OpenAlex
- W2020203617
- Cited by
- 211
- References
- 0
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.