The DOI matches its OpenAlex record; 2 of the 2 references it cites were found in a registry or an index.
Analysis of hindlimb muscle moment arms in Tyrannosaurus rex using a three-dimensional musculoskeletal computer model: implications for stance, gait, and speed
Open accessAbstract
Abstract Muscle moment arms are important determinants of muscle function; however, it is challenging to determine moment arms by inspecting bone specimens alone, as muscles have curvilinear paths that change as joints rotate. The goals of this study were to (1) develop a three-dimensional graphics-based model of the musculoskeletal system of the Cretaceous theropod dinosaur Tyrannosaurus rex that predicts muscle-tendon unit paths, lengths, and moment arms for a range of limb positions; (2) use the model to determine how the T. rex hindlimb muscle moment arms varied between crouched and upright poses; (3) compare the predicted moment arms with previous assessments of muscle function in dinosaurs; (4) evaluate how the magnitudes of these moment arms compare with those in other animals; and (5) integrate these findings with previous biomechanical studies to produce a revised appraisal of stance, gait, and speed in T. rex. The musculoskeletal model includes ten degrees of joint freedom (flexion/extension, ab/adduction, or medial/ lateral rotation) and 33 main muscle groups crossing the hip, knee, ankle, and toe joints of each hindlimb. The model was developed by acquiring and processing bone geometric data, defining joint rotation axes, justifying muscle attachment sites, and specifying muscle-tendon geometry and paths. Flexor and extensor muscle moment arms about all of the main limb joints were estimated, and limb orientation was statically varied to characterize how the muscle moment arms changed. We used sensitivity analysis of uncertain parameters, such as muscle origin and insertion centroids, to deterimine how much our conclusions depend on the muscle reconstruction we adopted. This shows that a specific amount of error in the reconstruction (e.g., position of muscle origins) can have a greater, lesser, similar, or no effect on the moment arms, depending on complex interactions between components of the musculoskeletal geometry. We found that more upright poses would have improved mechanical advantage of the muscles considerably. Our analysis shows that previously assumed moment arm values were generally conservatively high. Our results for muscle moment arms are generally lower than the values predicted by scaling data from extant taxa, suggesting that T. rex did not have the allometrically large muscle moment arms that might be expected in a proficient runner. The information provided by the model is important for determining how T. rex stood and walked, and how the muscles of a 4000–7000 kg biped might have worked in comparison with extant bipeds such as birds and humans. Our model thus strengthens the conclusion that T. rex was not an exceptionally fast runner, and supports the inference that more upright (although not completely columnar) poses are more plausible for T. rex. These results confirm general principles about the relationship between size, limb orientation, and locomotor mechanics: exceptionally big animals have a more limited range of locomotor abilities and tend to adopt more upright poses that improve extensor muscle effective mechanical advantage. This model builds on previous phylogenetically based muscle reconstructions and so moves closer to a fully dynamic, three-dimensional model of stance, gait, and speed in T. rex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variation of rotation moment arms with hip flexion
Delp, S. L., Hess, W. E., Hungerford, D. S., & Jones, L. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00032-9 · Cited by 362
Self-citationCaudofemoral musculature and the evolution of theropod locomotion
Gatesy, S. M. (1990) · Paleobiology · doi:10.1017/s0094837300009866 · Cited by 312
Cited by
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Self-citationFalkingham, P. (2012) · Palaeontologia Electronica · doi:10.26879/264 · Cited by 300
The evolutionary continuum of limb function from early theropods to birds
Hutchinson, J. R., & Allen, V. (2009) · Naturwissenschaften · doi:10.1007/s00114-008-0488-3 · Cited by 163
Self-citation
Metadata
- Authors
- Hutchinson, J. R., Anderson, F. C., Blemker, S. S., & Delp, S. L.
- Venue
- Paleobiology
- Publisher
- Cambridge University Press
- Published
- 2005-01-01
- Volume
- 31
- Issue
- 4
- Pages
- 676-676
- ISSN
- 0094-8373 (ISSN-L)
- OpenAlex
- W4255662033
- Cited by
- 226
- References
- 2
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.