CoChat

Integration of Monte Carlo Simulations with PFGE Experimental Data Yields Constant RBE of 2.3 for DNA Double-Strand Break Induction by Nitrogen Ions between 125 and 225 keV/μm LET

Alloni, D., Campa, A., Friedland, W., Mariotti, L., Ottolenghi, A. · 2013 · Radiation Research
Cited by 20

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The number of small radiation-induced DNA fragments can be heavily underestimated when determined from measurements of DNA mass fractions by gel electrophoresis, leading to a consequent underestimation of the initial DNA damage induction. In this study we reanalyzed the experimental results for DNA fragmentation and DNA double-strand break (DSB) yields in human fibroblasts irradiated with γ rays and nitrogen ion beams with linear energy transfer (LET) equal to 80, 125, 175 and 225 keV/μm, originally measured by Höglund et al. (Radiat Res 155, 818-825, 2001 and Int J Radiat Biol 76, 539-547, 2000). In that study the authors converted the measured distributions of fragment masses into DNA fragment distributions using mid-range values of the measured fragment length intervals, in particular they assumed fragments with lengths in the interval of 0-48 kbp had the mid-range value of 24 kbp. However, our recent detailed simulations with the Monte Carlo code PARTRAC, while reasonably in agreement with the mass distributions, indicate significantly increased yields of very short fragments by high-LET radiation, so that the actual average fragment lengths, in the interval 0-48 kbp, 2.4 kbp for 225 keV/μm nitrogen ions were much shorter than the assumed mid-range value of 24 kbp. When the measured distributions of fragment masses are converted into fragment distributions using the average fragment lengths calculated by PARTRAC, significantly higher yields of DSB related to short fragments were obtained and resulted in a constant relative biological effectiveness (RBE) for DSB induction yield of 2.3 for nitrogen ions at 125-225 keV/μm LET. The previously reported downward trend of the RBE values over this LET range for DSB induction appears to be an artifact of an inadequate average fragment length in the smallest interval.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1667/r3043.1

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 20

Metadata

Authors
Alloni, D., Campa, A., Friedland, W., Mariotti, L., & Ottolenghi, A.
Venue
Radiation Research
Published
2013-06
Volume
179
Issue
6
Pages
690-697
ISSN
  • 0033-7587 (ISSN-L)
  • 1938-5404
OpenAlex
W2125221903
Cited by
20
References
6
FWCI
2.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.