Cited by 96Thermodynamic and Exergetic Analyses of Power and Cooling SystemsPower Systems and Renewable EnergyIntegrated Energy Systems Optimization

An analysis of a large-scale liquid air energy storage system

Open access
Morgan, Robert, Nelmes, Stuart, Gibson, Emma, Brett, Gareth·2015·Proceedings of the Institution of Civil Engineers - Energy

Abstract

Liquid air energy storage (LAES) is a class of thermo-electric energy storage that utilises cryogenic or liquid air as the storage medium. The system is charged using an air liquefier and energy is recovered through a Rankine cycle using the stored liquid air as the working fluid. The recovery, storage and recycling of cold thermal energy released during discharge more than double the overall energy efficiency of the cycle. The demand on a storage plant in a grid support application is expected to be irregular and intermittent in response to fluctuating supply from intermittent renewable generators. This will complicate the storage of thermal energy and will mean the energy flow rates in the thermal store will vary from cycle to cycle and the state of charge of the store will also vary. This paper presents an analysis of the LAES cycle. The material and configuration of the cold thermal store is discussed in particular with reference to scale and measures to mitigate losses due to the irregular and intermittent duty cycle. The paper concludes with capital and levelised cost analysis of a reference 20 MW/80 MWh LAES plant and a comparison of the levelised cost with other storage technologies.

Integrity signals

Registry

Crossref · 10.1680/ener.14.00038

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cold recovery and storage significantly increase system efficiency.

    “One of the key findings from the testing of the first pilot plant was the significant increase of system efficiency by cold recovery and storage [6].”
  • Different assumptions in the different references make comparing the various configurations problematic.

    “In general, different assumptions are made in the different references, e.g., ideal dry air was assumed, heat and pressure losses in most components as well as heat losses in the cold box were neglected [12], or assumed lower than 8% [6] which is why comparing the various configurations is problematic.”
  • The specific investment costs of the total CES system is approximated from 500-3,000 €/kW in literature.

    “The specific investment costs of the total CES system is approximated from 500-3,000 €/kW [6,7,36] in literature.”

Cited by

Sorted by citations

Authors
Morgan, R., Nelmes, S., Gibson, E., & Brett, G.
Affiliations
  • University of Brighton (GB)
  • Highview Power Storage (United Kingdom) (GB)
Venue
Proceedings of the Institution of Civil Engineers - Energy
Publisher
Emerald
Published
2015-05
Volume
168
Issue
2
Pages
135-144
ISSN
  • 1751-4223 (ISSN-L)
  • 1751-4231
OpenAlex
W2001356071
Cited by
96
References
0
Citations by year
2026: 8 · 2025: 12 · 2024: 11 · 2023: 9 · 2022: 10 · 2021: 14 · 2020: 12 · 2019: 10 · 2018: 2 · 2017: 6 · 2016: 1 · 2015: 1
FWCI
3.27
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Proceedings of the Institution of Civil Engineers - Energy (publishedVersion)
  • University of Brighton Repository (University of Brighton) (publishedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
  • Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
Keywords
liquid air energy storage, cryogenic energy storage, Rankine cycle, intermittent renewable generation, grid support, duty cycle, levelized cost of electricity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review