Meta-Analysis: Peritoneal Membrane Transport, Mortality, and Technique Failure in Peritoneal Dialysis
Abstract
Peritoneal membrane solute transport in peritoneal dialysis (PD) patients is assessed by the peritoneal equilibration test, which measures the ratio of creatinine in the dialysate to plasma after a standardized 4-h dwell (D/Pc). Patients then are classified as high, high-average, low-average, or low transporters on the basis of this result. A meta-analysis of observational studies was carried out to characterize the relationship between D/Pc and mortality and technique failure in patients who are on PD. Citations were identified in Medline by using a combination of Medical Subject Heading search terms and key words related to PD, peritoneal membrane permeability/transport, and mortality and technique failure. The table of contents of relevant journals and bibliographies of relevant citations were reviewed in duplicate. Twenty studies that met study criteria were identified. Nineteen studies were pooled to generate a summary mortality relative risk of 1.15 for every 0.1 increase in the D/Pc (95% confidence interval 1.07 to 1.23; P < 001). This result equated to an increased mortality risk of 21.9, 45.7, and 77.3% in low-average, high-average, and high transporters, respectively, as compared with patients with low transport status. Meta-regression analysis showed that the proportion of patients who were on continuous cycler PD within a study was inversely proportional to the mortality risk (P = 0.05). The pooled summary relative risk for death-censored technique failure was 1.18 (95% confidence interval 0.96 to 1.46; P = 0.12) for every 0.1 increase in the D/Pc. This meta-analysis demonstrates that a higher peritoneal membrane solute transport rate is associated with a higher mortality risk and a trend to higher technique failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Operating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
Parmar, M. K. B., Torri, V., & Stewart, L. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19981230)17:24<2815::aid-sim110>3.0.co;2-8 · Cited by 4,802
Epidemiologic Research: Principles and Quantitative Methods.
Mayer, L. S., Kleinbaum, D. G., Kupper, L. L., & Morgenstern, H. (1984) · Journal of the American Statistical Association · doi:10.2307/2288427 · Cited by 2,905
Methods for Trend Estimation from Summarized Dose-Response Data, with Applications to Meta-Analysis
Greenland, S., & Longnecker, M. P. (1992) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116237 · Cited by 2,353
QUANTITATIVE METHODS IN THE REVIEW OF EPIDEMIOLOGIC LITERATURE1
GREENLAND, S. (1987) · Epidemiologic Reviews · doi:10.1093/oxfordjournals.epirev.a036298 · Cited by 1,644
Karl, Z. J. T., Khanna, O. N. R., Leonor, B. F. P., Ryan, P., Moore, H. L., & Nielsen, M. P. (1987) · Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · doi:10.1177/089686088700700306 · Cited by 1,059
Paniagua, R., Amato, D., Vonesh, E., Correa-Rotter, R., Ramos, A., Moran, J., & Mujais, S. (2002) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1351307 · Cited by 973
BARGMAN, J. M., THORPE, K. E., & CHURCHILL, D. N. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v12102158 · Cited by 918
Meta-analysis of Epidemiologic Dose-Response Data
Berlin, J. A., Longnecker, M. P., & Greenland, S. (1993) · Epidemiology · doi:10.1097/00001648-199305000-00005 · Cited by 571
Cited by
Rediscovering Beta-2 Microglobulin As a Biomarker across the Spectrum of Kidney Diseases
Argyropoulos, C. P., Chen, S. S., Ng, Y.-H., Roumelioti, M.-E., Shaffi, K., Singh, P. P., & Tzamaloukas, A. H. (2017) · Frontiers in Medicine · doi:10.3389/fmed.2017.00073 · Cited by 308
The Pathophysiology of the Peritoneal Membrane
Devuyst, O., Margetts, P. J., & Topley, N. (2010) · Journal of the American Society of Nephrology · doi:10.1681/asn.2009070694 · Cited by 271
Self-citation
Metadata
- Authors
- Brimble, K. S., Walker, M., Margetts, P. J., Kundhal, K. K., & Rabbat, C. G.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2006-09
- Volume
- 17
- Issue
- 9
- Pages
- 2591-2598
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2143350262
- Cited by
- 260
- References
- 26
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meta-Analysis: Peritoneal Membrane Transport, Mortality, and Technique Failure in Peritoneal Dialysis. https://app.cochat.ai/papers/10.1681/asn.2006030194
- The paper
- Brimble, K. S., Walker, M., Margetts, P. J., Kundhal, K. K., & Rabbat, C. G. (2006). Meta-Analysis: Peritoneal Membrane Transport, Mortality, and Technique Failure in Peritoneal Dialysis. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2006030194
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.