Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 231

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Morphometric and Visual Evaluation of Fibrosis in Renal Biopsies

Open access
Farris, Alton B., Adams, Catherine D., Brousaides, Nicole, Della Pelle, Patricia A., Collins, A. Bernard, Moradi, Ellie, Smith, R. Neal, Grimm, Paul C., Colvin, Robert B. · 2011 · Journal of the American Society of Nephrology

Abstract

Interstitial fibrosis is an outcome measure of increasing importance in clinical trials of both renal transplantation and native disease, but data on the comparative advantages of fibrosis measurement methods are limited. We compared four morphometric techniques and contrasted these with two visual fibrosis-scoring methods on trichrome-stained slides. Two morphometric methods included whole-slide digital images: collagen III immunohistochemistry and a new technique using trichrome and periodic acid-Schiff subtraction morphometry; the other two methods included Sirius Red with and without polarization on multiple digital fields. We evaluated 10 serial sections from 15 renal biopsies with a range of fibrosis extent and diagnoses on duplicate sections with each method on separate days. Three pathologists performed visual scoring on whole-slide images. Visual and morphometric techniques had good to excellent interassay reproducibility (R(2) = 0.62 to 0.96) and interobserver reproducibility (R(2) = 0.75 to 0.99, all P < 0.001). Morphometry showed less variation between observers than visual assessment (mean of 1% to 5% versus 11% to 13%). Collagen III, Sirius Red unpolarized, and visual scores had the strongest correlations (R(2) = 0.78 to 0.89), the greatest dynamic range, and the best correlation with estimated GFR (R(2) = 0.38 to 0.50, P < 0.01 to 0.001). Considering efficiency, reproducibility, and functional correlation, two current techniques stand out as potentially the best for clinical trials: collagen III morphometry and visual assessment of trichrome-stained slides.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2009091005

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 231

Metadata

Authors
Farris, A. B., Adams, C. D., Brousaides, N., Della Pelle, P. A., Collins, A. B., Moradi, E., Smith, R. N., Grimm, P. C., & Colvin, R. B.
Venue
Journal of the American Society of Nephrology
Published
2011-01
Volume
22
Issue
1
Pages
176-186
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2126677023
Cited by
231
References
3
FWCI
5.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphometric and Visual Evaluation of Fibrosis in Renal Biopsies. https://app.cochat.ai/papers/10.1681/asn.2009091005
The paper
Farris, A. B., Adams, C. D., Brousaides, N., Della Pelle, P. A., Collins, A. B., Moradi, E., Smith, R. N., Grimm, P. C., & Colvin, R. B. (2011). Morphometric and Visual Evaluation of Fibrosis in Renal Biopsies. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2009091005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.