CoChat

Prediction of Arteriovenous Fistula Clinical Maturation from Postoperative Ultrasound Measurements: Findings from the Hemodialysis Fistula Maturation Study

Open access
Robbin, Michelle L., Greene, Tom, Allon, Michael, Dember, Laura M., Imrey, Peter B., Cheung, Alfred K., Himmelfarb, Jonathan, Huber, Thomas S., Kaufman, James S., Radeva, Milena K., Roy-Chaudhury, Prabir, Shiu, Yan-Ting, Vazquez, Miguel A., Umphrey, Heidi R., Alexander, Lauren, Abts, Carl, Beck, Gerald J., Kusek, John W., Feldman, Harold I., the Hemodialysis Fistula Maturation Study Group · 2018 · Journal of the American Society of Nephrology
Cited by 181

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

Background: The utility of early postoperative ultrasound measurements in predicting arteriovenous fistula (AVF) clinical maturation is uncertain. Methods: We investigated the relationships of ultrasound parameters with AVF clinical maturation in newly created AVF, measured at 1 day and 2 and 6 weeks, in 602 participants of a multicenter, observational cohort study. A backward elimination algorithm identified ultrasound measurements that independently predicted unassisted and overall AVF maturation. Candidate variables included AVF blood flow, diameter, and depth, upper arm arterial diameter, presence of stenosis, presence of accessory veins, seven case-mix factors (age, sex, black race, AVF location, diabetes, dialysis status, and body mass index), and clinical center. We evaluated the accuracy of the resulting models for clinical prediction. Results: At each ultrasound measurement time, AVF blood flow, diameter, and depth each predicted in a statistically significant manner both unassisted and overall clinical maturation. Moreover, neither the remaining ultrasound parameters nor case-mix factors were associated with clinical AVF maturation after accounting for blood flow, diameter, and depth, although maturation probabilities differed among clinical centers before and after accounting for these parameters. The crossvalidated area under the receiver operating characteristic curve for models constructed using these three ultrasound parameters was 0.69, 0.74, and 0.79 at 1 day and 2 and 6 weeks, respectively, for unassisted AVF clinical maturation and 0.69, 0.71, and 0.76, respectively, for overall AVF maturation. Conclusions: AVF blood flow, diameter, and depth moderately predicted unassisted and overall AVF clinical maturation. The other factors considered did not further improve AVF maturation prediction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2017111225

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

Metadata

Authors
Robbin, M. L., Greene, T., Allon, M., Dember, L. M., Imrey, P. B., Cheung, A. K., Himmelfarb, J., Huber, T. S., Kaufman, J. S., Radeva, M. K., Roy-Chaudhury, P., Shiu, Y.-T., Vazquez, M. A., Umphrey, H. R., Alexander, L., Abts, C., Beck, G. J., Kusek, J. W., Feldman, H. I., & the Hemodialysis Fistula Maturation Study Group
Venue
Journal of the American Society of Nephrology
Published
2018-10-11
Volume
29
Issue
11
Pages
2735-2744
ISSN
  • 1046-6673 (ISSN-L)
  • 1533-3450
OpenAlex
W2895965108
Cited by
181
References
27
FWCI
20.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.