The DOI matches its Crossref record.
Detection of the Complement Degradation Product C4d in Renal Allografts: Diagnostic and Therapeutic Implications
Abstract
The immunohistochemical detection of the complement degradation product C4d, a component of the classical complement pathway, offers a new and currently poorly defined tool in the evaluation of renal allograft biopsies. Our retrospective study aims at determining the diagnostic and clinical significance of C4d accumulation in kidney transplants, employing immunofluorescence microscopy. We analyzed 398 diagnostic allograft biopsies (n = 265 patients with 1 to 5 biopsies obtained 7 to 7165 d posttransplantation [tx]) and correlated the detection of C4d with 18 histologic changes, panel-reactive antibody titers, response to treatment, and outcome. One hundred twenty-five native kidney and baseline tx biopsies served as controls. Linear deposition of C4d along peritubular capillaries was only found in a subgroup (30%) of allografts post-tx, mainly during the early time-course (median, 38 d post-tx; range, 7 to 5646 d). There was no significant association with infections. C4d staining could change from negative to positive and vice versa within days to weeks. The accumulation of C4d was most tightly linked to a morphologic subtype of rejection, transplant glomerulitis (P < 0.0001). In addition, tubular MHC class II expression was correlated with C4d deposition (P < 0.0001). Both features are signs of "acute active rejection." In comparison with C4d-negative controls, 43% of C4d-positive patients showed increased (>10%) panel-reactive antibody titers (versus 19% in the negative group; P = 0.001). C4d positivity was frequently associated with higher serum creatinine levels at time of biopsy (compared with C4d-negative group; P < 0.01). More C4d-positive patients were treated with polyclonal antithymocyte globulins (ATG) or monoclonal anti-CD3 antibodies (OKT3) (P < 0.0001). Outcome did not significantly differ between C4d-positive and C4d-negative groups. In conclusion, the detection of C4d identifies a humoral alloresponse in a subgroup of kidney transplants, which is often associated with signs of cellular rejection, i.e. tx glomerulitis. Allograft dysfunction in C4d-positive rejection episodes is often more pronounced. We provide first evidence that C4d-positive rejection might benefit from intensive therapy, potentially preventing the previously reported high graft failure rate. In addition, we show that a subgroup of C4d-positive cases may not require any immediate therapeutic intervention. The presence of C4d is clinically relevant and should be reported in the histologic diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solez, K., Colvin, R., Racusen, L., Sis, B., Halloran, P., Birk, P., Campbell, P., Cascalho, M., Collins, A., Demetris, A., et al. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2006.01688.x · Cited by 1,082
Self-citationRegele, H., Böhmig, G. A., Habicht, A., Gollowitzer, D., Schillinger, M., Rockenschaub, S., Watschinger, B., Kerjaschki, D., & Exner, M. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000025780.03790.0f · Cited by 423
Effector Mechanisms of Rejection
Moreau, A., Varey, E., Anegon, I., & Cuturi, M.-C. (2013) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a015461 · Cited by 189
Metadata
- Authors
- Nickeleit, V., Zeiler, M., Gudat, F., Thiel, G., & Mihatsch, M. J.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2002-01
- Volume
- 13
- Issue
- 1
- Pages
- 242-251
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2164993846
- Cited by
- 311
- References
- 0
- FWCI
- 14.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of the Complement Degradation Product C4d in Renal Allografts: Diagnostic and Therapeutic Implications. https://app.cochat.ai/papers/10.1681/asn.v131242
- The paper
- Nickeleit, V., Zeiler, M., Gudat, F., Thiel, G., & Mihatsch, M. J. (2002). Detection of the Complement Degradation Product C4d in Renal Allografts: Diagnostic and Therapeutic Implications. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v131242
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.