Cited by 15Non-Invasive Vital Sign MonitoringPeripheral Artery Disease ManagementDiabetic Foot Ulcer Assessment and Management

Potential application of photoplethysmography technique in evaluating microcirculatory status of STAMP patients: Preliminary report

Lee, Thay Q., Barnett, Steven L., Shanfield, Stewart L., Anzel, Sanford H.·1990·The Journal of Rehabilitation Research and Development

Abstract

Diabetes mellitus and peripheral vascular disease often lead to infections that result in lower extremity amputations. Transcutaneous oxygen pressure (TcPO2) has been shown by many investigators to be a highly reliable means of assessing cutaneous blood supply and, thus, predicting healing potential. However, TcPO2 measurements are time-consuming and subject to technical difficulties. For this reason, a potential application of photoplethysmography (PPG) as a method for assessing the level of cutaneous circulation was investigated by comparing PPG peak-to-peak voltages with corresponding TcPO2 measurements. The comparisons were made at 37 locations in 20 patients with an age range of from 20 to 81 years (mean = 64.4 years). Although the two methods are intrinsically different and measure two different physiological parameters, the peak-to-peak voltages from PPG were compared with TcPO2 measurements since TcPO2 was reported to be the best single adjunct in determining healing potential after amputation. Linear regression analysis correlating output peak-to-peak voltages from PPG with TcPO2 yielded a correlation coefficient of 0.60. The anatomic locations did not affect the PPG or the TcPO2 measurement. The results of this study encourage further investigation of this technique and instrumentation as a method of assessing the level of cutaneous circulation and ultimately aid in determination of optimal amputation levels.

Integrity signals

Registry

Crossref · 10.1682/jrrd.1990.10.0363

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, T. Q., Barnett, S. L., Shanfield, S. L., & Anzel, S. H.
Affiliations
  • United States Department of Veterans Affairs (US)
  • VA Long Beach Healthcare System (US)
Venue
The Journal of Rehabilitation Research and Development
Published
1990
Volume
27
Issue
4
Pages
363
ISSN
  • 0742-3241 (ISSN-L)
  • 0748-7711
OpenAlex
W2013625733
Cited by
15
References
9
Citations by year
2023: 1 · 2022: 2 · 2021: 1 · 2017: 1 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Rehabilitation Research and Development (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Peripheral Artery Disease Management
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetic Foot Ulcer Assessment and Management
Keywords
photoplethysmography, transcutaneous oxygen tension, microcirculation, stamps, diabetic foot, amputation, lower limb amputation, peak-to-peak voltage, peripheral vascular disease
MeSH terms
Adult, Aged, Aged, 80 and over, Amputation, Surgical, Blood Gas Monitoring, Transcutaneous, Carbon Dioxide, Diabetic Angiopathies, Female, Humans, Male, Microcirculation, Middle Aged, Oxygen, Plethysmography, Pulsatile Flow, Skin, Supination

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review