Tools for understanding and optimizing robotic gait training
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This article reviews several tools we have developed to improve the understanding of locomotor training following spinal cord injury (SCI), with a view toward implementing locomotor training with robotic devices. We have developed (1) a small-scale robotic device that allows testing of locomotor training techniques in rodent models, (2) an instrumentation system that measures the forces and motions used by experienced human therapists as they manually assist leg movement during locomotor training, (3) a powerful, lightweight leg robot that allows investigation of motor adaptation during stepping in response to force-field perturbations, and (4) computational models for locomotor training. Results from the initial use of these tools suggest that an optimal gait-training robot will minimize disruptive sensory input, facilitate appropriate sensory input and gait mechanics, and intelligently grade and time its assistance. Currently, we are developing a pneumatic robot designed to meet these specifications as it assists leg and pelvic motion of people with SCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive representation of dynamics during learning of a motor task
Shadmehr, R., & Mussa-Ivaldi, F. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-05-03208.1994 · Cited by 2,612
Patton, J. L., Stoykov, M. E., Kovic, M., & Mussa-Ivaldi, F. A. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0097-8 · Cited by 469 · cited 1×
“If larger stepping errors are tolerable, then amplifying errors may accelerate learning, as reviewed here for stepping experiments with nondisabled subjects [28] and elsewhere for reaching movements by nondisabled and stroke subjects [40–41].”
BackgroundEmken, J. L., & Reinkensmeyer, D. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.843173 · Cited by 300 · cited 10×
“The leg robot ARTHuR has the potential to be used as a gait-training device, but it is relatively expensive and cannot assist at both the knee and the lower shank as experienced therapists commonly do.”
BackgroundMethodInfluentialSelf-citation
Cited by
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Hornby, T. G., Campbell, D. D., Kahn, J. H., Demott, T., Moore, J. L., & Roth, H. R. (2008) · Stroke · doi:10.1161/strokeaha.107.504779 · Cited by 541
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Compliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448
Metadata
- Authors
- Reinkensmeyer, D. J., Aoyagi, D., Emken, J. L., Galvez, J. A., Ichinose, W., Kerdanyan, G., Maneekobkunwong, S., Minakata, K., Nessler, J. A., Weber, R., Roy, R. R., Leon, R. D., Bobrow, J. E., Harkema, S. J., & Edgerton, V. R.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2006
- Volume
- 43
- Issue
- 5
- Pages
- 657
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2142117918
- Cited by
- 146
- References
- 3
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.