Neurotherapeutic and neuroprosthetic effects of implanted functional electrical stimulation for ambulation after incomplete spinal cord injury
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this single-subject study was to determine the neurotherapeutic and neuroprosthetic effects of an implanted functional electrical stimulation (FES) system designed to facilitate walking in an individual with a longstanding motor and sensory incomplete spinal cord injury. An implanted pulse generator and eight intramuscular stimulating electrodes were installed unilaterally, activating weak or paralyzed hip flexors, hip and knee extensors, and ankle dorsiflexors during 36 sessions of gait training with FES. The neurotherapeutic effects were assessed by a comparison of pre- and posttraining volitional walking. The neuroprosthetic effects were assessed by a comparison of posttraining volitional and FES-assisted walking. Treatment resulted in significant (p < 0.005) volitional improvements in 6-minute walking distance and speed, speed during maximum walk, double support time, and 10 m walking speed. Posttraining FES-assisted walking resulted in significant additional improvements in all these measures, except 10 m walking speed. When the subject was using FES-assisted gait, maximum walking distance, peak knee flexion in swing, peak ankle dorsiflexion in swing, and knee extension moment also significantly increased. Neuroprosthetic gains were sufficient to enable the subject to advance from household ambulation to limited community ambulation. Additionally, the subject could perform multiple walks per day when using FES-assisted gait, which was impossible with volitional effort alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155 · cited 1×
“Neuroprosthetic interventions employ FES to assist tasks such as standing or walking [12].”
Self-citation
Cited by
“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97
Self-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Closed-loop functional optogenetic stimulation
Srinivasan, S. S., Maimon, B. E., Diaz, M., Song, H., & Herr, H. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07721-w · Cited by 68
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
“in stroke survivors [22–24].”
Self-citation
Metadata
- Authors
- Nogan Bailey, S., Hardin, E. C., Kobetic, R., Boggs, L. M., Pinault, G., & Triolo, R. J.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2010
- Volume
- 47
- Issue
- 1
- Pages
- 7
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W1964981124
- Cited by
- 39
- References
- 1
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neurotherapeutic and neuroprosthetic effects of implanted functional electrical stimulation for ambulation after incomplete spinal cord injury. https://app.cochat.ai/papers/10.1682/jrrd.2009.03.0034
- The paper
- Nogan Bailey, S., Hardin, E. C., Kobetic, R., Boggs, L. M., Pinault, G., & Triolo, R. J. (2010). Neurotherapeutic and neuroprosthetic effects of implanted functional electrical stimulation for ambulation after incomplete spinal cord injury. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2009.03.0034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.