Test No. 437: Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage
The DOI matches its Crossref record.
Abstract
The Bovine Corneal Opacity and Permeability test method (BCOP) is an in vitro test method that can be used to identify chemicals (substances or mixtures) as either 1) causing "serious eye damage" (category 1 of the Globally Harmonised System for the Classification and Labelling of chemicals (GHS)), or 2) not requiring classification for eye irritation or serious eye damage according to the GHS. The BCOP uses isolated corneas from the eyes of cattle slaughtered for commercial purposes, thus avoiding the use of laboratory animals. Each treatment group (test chemical, negative/positive controls) consists of a minimum of three eyes where the cornea has been excised and mounted to a holder. Depending on the physical nature and chemical characteristics of the test chemical, different methods can be used for its application since the critical factor is ensuring that the test chemical adequately covers the epithelial surface. Toxic effects to the cornea are measured as opacity and permeability, which when combined gives an In Vitro Irritancy Score (IVIS) for each treatment group. A chemical that induces an IVIS ≥ 55.1 is defined as a category 1 ("causing serious eye damage" according to the GHS); a chemical that induces an IVIS≤ 3 is considered as not requiring classification for eye irritation or serious eye damage according to the GHS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidance Document on Good In Vitro Method Practices (GIVIMP)
OECD (2018) · OECD Series on Testing and Assessment · doi:10.1787/9789264304796-en · Cited by 161
Self-citationSilva, R. J., & Tamburic, S. (2022) · Cosmetics · doi:10.3390/cosmetics9050090 · Cited by 63
Alternative methods to animal testing for the safety evaluation of cosmetic ingredients: an overview
Vinardell, M., & Mitjans, M. (2017) · Cosmetics · doi:10.3390/cosmetics4030030 · Cited by 37
Gabbert, S., Mathea, M., Kolle, S. N., & Landsiedel, R. (2022) · Risk Analysis · doi:10.1111/risa.13648 · Cited by 17
Kolle, S. N., Mathea, M., Natsch, A., & Landsiedel, R. (2021) · Applied In Vitro Toxicology · doi:10.1089/aivt.2021.0003 · Cited by 16
Metadata
- Authors
- OECD
- Venue
- OECD Guidelines for the Testing of Chemicals, Section 4
- Publisher
- OECD Publishing
- Published
- 2025-06-25
- ISSN
- 2074-5788 (ISSN-L)
- OpenAlex
- W4210412278
- Cited by
- 82
- References
- 0
- FWCI
- 3.96
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test No. 437: Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage. https://app.cochat.ai/papers/10.1787/9789264203846-en
- The paper
- OECD. (2025). Test No. 437: Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage. OECD Guidelines for the Testing of Chemicals, Section 4. https://doi.org/10.1787/9789264203846-en
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.