A novel microfluidic model can mimic organ-specific metastasis of circulating tumor cells
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
// Jing Kong 1 , Yong Luo 2 , Dong Jin 1 , Fan An 2 , Wenyuan Zhang 1 , Lilu Liu 1 , Jiao Li 1 , Shimeng Fang 1 , Xiaojie Li 1 , Xuesong Yang 3 , Bingcheng Lin 2, 4 , Tingjiao Liu 1 1 College of Stomatology, Dalian Medical University, Dalian, China 2 Faculty of Chemical, Environmental and Biological Science and Technology, Dalian Technology University, Dalian, China 3 Department of Biochemistry and Molecular Biology, Liaoning Provincial Core Lab of Glycobiology and Glycoengineering, Dalian Medical University, Dalian, China 4 Department of Biotechnology, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, China Correspondence to: Tingjiao Liu, email: tingjiao@dlmedu.edu.cn Bingcheng Lin, email: bclin@dicp.ac.cn Keywords: microfluidic, metastasis, circulating tumor cells, multi-organ, bionic model Received: February 13, 2016 Accepted: April 02, 2016 Published: May 15, 2016 ABSTRACT A biomimetic microsystem might compensate costly and time-consuming animal metastatic models. Herein we developed a biomimetic microfluidic model to study cancer metastasis. Primary cells isolated from different organs were cultured on the microlfuidic model to represent individual organs. Breast and salivary gland cancer cells were driven to flow over primary cell culture chambers, mimicking dynamic adhesion of circulating tumor cells (CTCs) to endothelium in vivo . These flowing artificial CTCs showed different metastatic potentials to lung on the microfluidic model. The traditional nude mouse model of lung metastasis was performed to investigate the physiological similarity of the microfluidic model to animal models. It was found that the metastatic potential of different cancer cells assessed by the microfluidic model was in agreement with that assessed by the nude mouse model. Furthermore, it was demonstrated that the metastatic inhibitor AMD3100 inhibited lung metastasis effectively in both the microfluidic model and the nude mouse model. Then the microfluidic model was used to mimick liver and bone metastasis of CTCs and confirm the potential for research of multiple-organ metastasis. Thus, the metastasis of CTCs to different organs was reconstituted on the microfluidic model. It may expand the capabilities of traditional cell culture models, providing a low-cost, time-saving, and rapid alternative to animal models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Genes that mediate breast cancer metastasis to lung
Minn, A. J., Gupta, G. P., Siegel, P. M., Bos, P. D., Shu, W., Giri, D. D., Viale, A., Olshen, A. B., Gerald, W. L., & Massagué, J. (2005) · Nature · doi:10.1038/nature03799 · Cited by 2,922
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872 · cited 1×
“HUVECs have been previously reported to be served as the vascular endothelial barrier [29, 31, 45, 46].”
BackgroundBillingsley, K. G., Burt, M. E., Jara, E., Ginsberg, R. J., Woodruff, J. M., Leung, D. H. Y., & Brennan, M. F. (1999) · Annals of Surgery · doi:10.1097/00000658-199905000-00002 · Cited by 623
Tumour-on-a-chip provides an optical window into nanoparticle tissue transport
Albanese, A., Lam, A. K., Sykes, E. A., Rocheleau, J. V., & Chan, W. C. W. (2013) · Nature Communications · doi:10.1038/ncomms3718 · Cited by 330
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Buchanan, C. F., Verbridge, S. S., Vlachos, P. P., & Rylander, M. N. (2014) · Cell Adhesion & Migration · doi:10.4161/19336918.2014.970001 · Cited by 205
A microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159
Cited by
Multiorgan-on-a-Chip: A Systemic Approach To Model and Decipher Inter-Organ Communication
Picollet-D’hahan, N., Zuchowska, A., Lemeunier, I., & Le Gac, S. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.11.014 · Cited by 379
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Recent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Fan, T. M., Roberts, R. D., & Lizardo, M. M. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.00013 · Cited by 90
Metadata
- Authors
- Kong, J., Luo, Y., Jin, D., An, F., Zhang, W., Liu, L., Li, J., Fang, S., Li, X., Yang, X., Lin, B., & Liu, T.
- Venue
- Oncotarget
- Publisher
- Impact Journals, LLC
- Published
- 2016-05-15
- Volume
- 7
- Issue
- 48
- Pages
- 78421-78432
- ISSN
- 1949-2553 (ISSN-L)
- OpenAlex
- W2371764406
- Cited by
- 72
- References
- 12
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel microfluidic model can mimic organ-specific metastasis of circulating tumor cells. https://app.cochat.ai/papers/10.18632/oncotarget.9382
- The paper
- Kong, J., Luo, Y., Jin, D., An, F., Zhang, W., Liu, L., Li, J., Fang, S., Li, X., Yang, X., Lin, B., & Liu, T. (2016). A novel microfluidic model can mimic organ-specific metastasis of circulating tumor cells. Oncotarget. https://doi.org/10.18632/oncotarget.9382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.