Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 504

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Biologic Width Around Titanium Implants. A Histometric Analysis of the Implanto‐Gingival Junction Around Unloaded and Loaded Nonsubmerged Implants in the Canine Mandible

Cochran, David L., Hermann, Joachim S., Schenk, Robert K., Higginbottom, Frank L., Buser, Daniel·1997·Journal of Periodontology

Abstract

T he use of endosseous dental implants as transmucosal devices necessitates the successful integration of three different tissues: bone, connective tissue, and epithelium. So far, studies have predominantly focused on hard tissue integration. Much less is known about soft tissues. This study examined the dimensions of the implantogingival junction in relation to clinically healthy unloaded and loaded nonsubmerged implants. In total, 69 titanium plasma‐sprayed (TPS) and sandblasted acid‐etched (SLA) implants were placed in an alternating fashion in six foxhounds and allowed to heal for 3 months. Two dogs were sacrificed after the initial healing period. The remaining four dogs had crowns fabricated that were allowed to function for up to 12 months. These animals were sacrificed after 3 and 12 months of loading. Histometric analysis of undecalcified histologic sections included the evaluation of the sulcus depth (SD), the dimensions of the junctional epithelium (JE), and the connective tissue contact (CTC). Mean values in the 3 month unloaded group were 0.49 mm for SD, 1.16 mm for JE, and 1.36 mm for CTC. These dimensions were 0.50 mm for SD, 1.44 mm for JE, and 1.01 mm for CTC for the 3 month loaded group. After 12 months of loading, these values were 0.16 mm for SD, 1.88 mm for JE, and 1.05 mm for CTC. The sum of these measurements was similar for the different time points and similar to the same dimensions around teeth. TPS and SLA surfaces had no influence on the evaluated parameters (P > 0.05). The data suggest that a biologic width exists around unloaded and loaded nonsubmerged one‐part titanium implants and that this is a physiologically formed and stable dimension as is found around teeth. J Periodontol 1997;68:186–198.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1902/jop.1997.68.2.186

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 504

Metadata

Authors
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D.
Venue
Journal of Periodontology
Publisher
Wiley
Published
1997-02
Volume
68
Issue
2
Pages
186-197
ISSN
  • 0022-3492 (ISSN-L)
  • 1943-3670
OpenAlex
W2133068289
Cited by
504
References
2
FWCI
15.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biologic Width Around Titanium Implants. A Histometric Analysis of the Implanto‐Gingival Junction Around Unloaded and Loaded Nonsubmerged Implants in the Canine Mandible. https://app.cochat.ai/papers/10.1902/jop.1997.68.2.186
The paper
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997). Biologic Width Around Titanium Implants. A Histometric Analysis of the Implanto‐Gingival Junction Around Unloaded and Loaded Nonsubmerged Implants in the Canine Mandible. Journal of Periodontology. https://doi.org/10.1902/jop.1997.68.2.186

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.