The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
Abstract
Abstract: Gingival esthetics around natural teeth is based upon a constant vertical dimension of healthy periodontal soft tissues, the Biologic Width. When placing endosseous implants, however, several factors influence periimplant soft and crestal hard tissue reactions, which are not well understood as of today. Therefore, the purpose of this study was to histometrically examine periimplant soft tissue dimensions dependent on varying locations of a rough/smooth implant border in one‐piece implants or a microgap (interface) in two‐piece implants in relation to the crest of the bone, with two‐piece implants being placed according to either a submerged or a nonsubmerged technique. Thus, 59 implants were placed in edentulous mandibular areas of five foxhounds in a side‐by‐side comparison. At the time of sacrifice, six months after implant placement, the Biologic Width dimension for one‐piece implants, with the rough/smooth border located at the bone crest level, was significantly smaller (P<0.05) compared to two‐piece implants with a microgap (interface) located at or below the crest of the bone. In addition, for one‐piece implants, the tip of the gingival margin (GM) was located significantly more coronally (P<0.005) compared to two‐piece implants. These findings, as evaluated by nondecalcified histology under unloaded conditions in the canine mandible, suggest that the gingival margin (GM) is located more coronally and Biologic Width (BW) dimensions are more similar to natural teeth around one‐piece nonsubmerged implants compared to either two‐piece nonsubmerged or two‐piece submerged implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The long-term efficacy of currently used dental implants: a review and proposed criteria of success.
Albrektsson, T. O., Zarb, G. A., Worthington, P., & Eriksson, A. R. (1986) · PubMed · Cited by 3,691
Dimensions and Relations of the Dentogingival Junction in Humans
Gargiulo, A. W., Wentz, F. M., & Orban, B. (1961) · The Journal of Periodontology · doi:10.1902/jop.1961.32.3.261 · Cited by 1,053
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
Criteria for success of osseointegrated endosseous implants
Smith, D. E., & Zarb, G. A. (1989) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90081-4 · Cited by 801
Dimension of the periimplant mucosa: Biological width revisited
Berglundh, T., & Lindhe, J. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00520.x · Cited by 798
Hermann, J. S., Cochran, D. L., Nummikoski, P. V., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.11.1117 · Cited by 678
Self-citationSHIINA, S., AOYAMA, H., SHIRATORI, Y., MUTOH, H., KURITA, M., OTA, S., TERANO, A., & SUGIMOTO, T. (1990) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199006000-00006 · Cited by 654
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.2.186 · Cited by 504
Self-citationBrown, W. A. B. (1985) · FEBS Letters · doi:10.1016/0014-5793(85)81367-3 · Cited by 495
The mucosal barrier following abutment dis/reconnection: An experimental study in dogs
Abrahamsson, I., Berglundh, T., & Lindhe, J. (1997) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1997.tb00230.x · Cited by 422
Cited by
Zirconia dental implants: where are we now, and where are we heading?
Cionca, N., Hashim, D., & Mombelli, A. (2017) · Periodontology 2000 · doi:10.1111/prd.12180 · Cited by 300
The biological width around implant
Zheng, Z., Ao, X., Xie, P., Jiang, F., & Chen, W. (2021) · Journal of Prosthodontic Research · doi:10.2186/jpr.jpor_2019_356 · Cited by 84
Metadata
- Authors
- Hermann, J. S., Cochran, D. L., Hermann, J. S., Buser, D., Schenk, R. K., & Schoolfield, J. D.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2001-12
- Volume
- 12
- Issue
- 6
- Pages
- 559-571
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1868776634
- Cited by
- 468
- References
- 21
- FWCI
- 10.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120603.x
- The paper
- Hermann, J. S., Cochran, D. L., Hermann, J. S., Buser, D., Schenk, R. K., & Schoolfield, J. D. (2001). Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120603.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.