Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 468

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible

Hermann, Joachim S., Cochran, David L., Hermann, Joachim S., Buser, Daniel, Schenk, Robert K., Schoolfield, John D.·2001·Clinical Oral Implants Research

Abstract

Abstract: Gingival esthetics around natural teeth is based upon a constant vertical dimension of healthy periodontal soft tissues, the Biologic Width. When placing endosseous implants, however, several factors influence periimplant soft and crestal hard tissue reactions, which are not well understood as of today. Therefore, the purpose of this study was to histometrically examine periimplant soft tissue dimensions dependent on varying locations of a rough/smooth implant border in one‐piece implants or a microgap (interface) in two‐piece implants in relation to the crest of the bone, with two‐piece implants being placed according to either a submerged or a nonsubmerged technique. Thus, 59 implants were placed in edentulous mandibular areas of five foxhounds in a side‐by‐side comparison. At the time of sacrifice, six months after implant placement, the Biologic Width dimension for one‐piece implants, with the rough/smooth border located at the bone crest level, was significantly smaller (P<0.05) compared to two‐piece implants with a microgap (interface) located at or below the crest of the bone. In addition, for one‐piece implants, the tip of the gingival margin (GM) was located significantly more coronally (P<0.005) compared to two‐piece implants. These findings, as evaluated by nondecalcified histology under unloaded conditions in the canine mandible, suggest that the gingival margin (GM) is located more coronally and Biologic Width (BW) dimensions are more similar to natural teeth around one‐piece nonsubmerged implants compared to either two‐piece nonsubmerged or two‐piece submerged implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0501.2001.120603.x

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 468

Metadata

Authors
Hermann, J. S., Cochran, D. L., Hermann, J. S., Buser, D., Schenk, R. K., & Schoolfield, J. D.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2001-12
Volume
12
Issue
6
Pages
559-571
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1868776634
Cited by
468
References
21
FWCI
10.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.120603.x
The paper
Hermann, J. S., Cochran, D. L., Hermann, J. S., Buser, D., Schenk, R. K., & Schoolfield, J. D. (2001). Biologic Width around one‐ and two‐piece titanium implants: A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.120603.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.