The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of Surface Hydrophilicity and Microtopography on Early Stages of Soft and Hard Tissue Integration at Non‐Submerged Titanium Implants: An Immunohistochemical Study in Dogs
Abstract
Background: The aim of the present study was to investigate the effects of surface hydrophilicity and microtopography on soft and hard tissue integration at non‐submerged titanium implants. Methods: Implantation of conventional sand‐blasted large grit and acid‐etched (SLA) and chemically modified SLA (modSLA) titanium implants with differently structured transmucosal surfaces (SLA implants: machined [M‐SLA] or SLA [SLA‐SLA]; modSLA implants: mod acid‐etched [modA] [modA‐modSLA] or modSLA [modSLA‐modSLA]) was performed bilaterally in the upper and lower jaws of 15 beagle dogs. The animals were sacrificed after 1, 4, 7, 14, or 28 days. Tissue reactions were assessed histomorphometrically and immunohistochemically using monoclonal antibodies to transglutaminase II (angiogenesis) and osteocalcin. Results: Although the junctional epithelium commonly was separated from M‐SLA and SLA‐SLA implants by a gap, the epithelial cells appeared to be in close contact with modA‐modSLA surfaces after 14 days of healing. Moreover, modA‐modSLA and modSLA‐modSLA groups showed a well‐vascularized subepithelial connective tissue exhibiting collagen fibers that started to extend and attach partially perpendicular to the implant surface. The highest and statistically significant mean bone‐to‐implant contact areas were observed in the modA‐modSLA and modSLA‐modSLA groups at days 7, 14, and 28. Conclusion: Within the limits of this study, it may be concluded that soft and hard tissue integration was influenced mainly by surface hydrophilicity rather than by microtopography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Cited by
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
A review on the wettability of dental implant surfaces II: Biological and clinical aspects
Gittens, R. A., Scheideler, L., Rupp, F., Hyzy, S. L., Geis-Gerstorfer, J., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.032 · Cited by 849
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Soft tissue wound healing around teeth and dental implants
Sculean, A., Gruber, R., & Bosshardt, D. D. (2014) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12206 · Cited by 439
Wall, I., Donos, N., Carlqvist, K., Jones, F., & Brett, P. (2009) · Bone · doi:10.1016/j.bone.2009.03.662 · Cited by 287
Metadata
- Authors
- Schwarz, F., Ferrari, D., Herten, M., Mihatovic, I., Wieland, M., Sager, M., & Becker, J.
- Venue
- Journal of Periodontology
- Publisher
- Wiley
- Published
- 2007-11
- Volume
- 78
- Issue
- 11
- Pages
- 2171-2184
- ISSN
- 0022-3492 (ISSN-L)
- 1943-3670
- OpenAlex
- W2132246474
- Cited by
- 211
- References
- 1
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Surface Hydrophilicity and Microtopography on Early Stages of Soft and Hard Tissue Integration at Non‐Submerged Titanium Implants: An Immunohistochemical Study in Dogs. https://app.cochat.ai/papers/10.1902/jop.2007.070157
- The paper
- Schwarz, F., Ferrari, D., Herten, M., Mihatovic, I., Wieland, M., Sager, M., & Becker, J. (2007). Effects of Surface Hydrophilicity and Microtopography on Early Stages of Soft and Hard Tissue Integration at Non‐Submerged Titanium Implants: An Immunohistochemical Study in Dogs. Journal of Periodontology. https://doi.org/10.1902/jop.2007.070157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.