Valve durability after transcatheter aortic valve implantation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure to treat severe symptomatic aortic stenosis. While the TAVI procedure can be performed safely and provide excellent 5-year results, little is known about long-term durability. TAVI valves are composed of bioprosthetic leaflets are prone to deterioration, which are categorized as structural valve deterioration (SVD) and non-SVD. SVD refers to an intrinsic pathology of the leaflets or stent structure with mechanisms that include leaflet calcification, leaflet tear, stent fracture, or stent creep. Non-SVD processes include valve thrombosis, infective endocarditis and patient prosthesis mismatch. TAVI valves degenerate by similar mechanisms as bioprosthetic surgical aortic valves. Unique mechanisms that contribute to TAVI degeneration include valve crimpling, balloon expansion, stent under-expansion and valve thrombosis. The absence of a universally accepted definition of SVD poses a challenge in estimating valve durability. Traditional surgical bioprosthetic aortic valves have demonstrated excellent durability with clinically relevant SVD of 6.6% at 10-year follow up. Long-term durability of TAVI valves, however, remain poorly defined. From meta-analysis TAVI trials, SVD was estimated at 7% at 5 years. With iterative improvements in TAVI valve construction and deployment techniques, long-term durability may improve. Until long-term outcomes are better understood, TAVI should be used with caution in younger patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345 · cited 1×
“Several randomized trials have established superiority of TAVI for the treatment of patients who have a prohibitive and high surgical mortality risk and as a reasonable alternative for older adults with an intermediate estimated surgical mortality risk (1-5).”
BackgroundTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739 · cited 1×
“(28) Edwards SAPIEN 699 5 years Reintervention: 0%”
Brown, J. M., O'Brien, S. M., Wu, C., Sikora, J. A. H., Griffith, B. P., & Gammie, J. S. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.08.015 · Cited by 937 · cited 1×
“In the United States, approximately 80% of SAVR is performed with a bioprosthetic implant (14).”
BackgroundTranscatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923 · cited 2×
“This process can lead to either stenosis, regurgitation or combined stenosis and regurgitation (43).”
BackgroundMethodParavalvular Leak After Transcatheter Aortic Valve Replacement
Généreux, P., Head, S. J., Hahn, R., Daneault, B., Kodali, S., Williams, M. R., van Mieghem, N. M., Alu, M. C., Serruys, P. W., Kappetein, A. P., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1039 · Cited by 447
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Self-citation2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
Self-citation2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Self-citationTranscatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Metadata
- Authors
- Kataruka, A., & Otto, C. M.
- Venue
- Journal of Thoracic Disease
- Publisher
- AME Publishing Company
- Published
- 2018-11
- Volume
- 10
- Issue
- S30
- Pages
- S3629-S3636
- ISSN
- 2072-1439 (ISSN-L)
- 2077-6624
- OpenAlex
- W2883298631
- Cited by
- 69
- References
- 7
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Valve durability after transcatheter aortic valve implantation. https://app.cochat.ai/papers/10.21037/jtd.2018.07.38
- The paper
- Kataruka, A., & Otto, C. M. (2018). Valve durability after transcatheter aortic valve implantation. Journal of Thoracic Disease. https://doi.org/10.21037/jtd.2018.07.38
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.