CoChat

Valve durability after transcatheter aortic valve implantation

Open access
Kataruka, Akash, Otto, Catherine M. · 2018 · Journal of Thoracic Disease
Cited by 69

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure to treat severe symptomatic aortic stenosis. While the TAVI procedure can be performed safely and provide excellent 5-year results, little is known about long-term durability. TAVI valves are composed of bioprosthetic leaflets are prone to deterioration, which are categorized as structural valve deterioration (SVD) and non-SVD. SVD refers to an intrinsic pathology of the leaflets or stent structure with mechanisms that include leaflet calcification, leaflet tear, stent fracture, or stent creep. Non-SVD processes include valve thrombosis, infective endocarditis and patient prosthesis mismatch. TAVI valves degenerate by similar mechanisms as bioprosthetic surgical aortic valves. Unique mechanisms that contribute to TAVI degeneration include valve crimpling, balloon expansion, stent under-expansion and valve thrombosis. The absence of a universally accepted definition of SVD poses a challenge in estimating valve durability. Traditional surgical bioprosthetic aortic valves have demonstrated excellent durability with clinically relevant SVD of 6.6% at 10-year follow up. Long-term durability of TAVI valves, however, remain poorly defined. From meta-analysis TAVI trials, SVD was estimated at 7% at 5 years. With iterative improvements in TAVI valve construction and deployment techniques, long-term durability may improve. Until long-term outcomes are better understood, TAVI should be used with caution in younger patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/jtd.2018.07.38

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 69

Metadata

Authors
Kataruka, A., & Otto, C. M.
Venue
Journal of Thoracic Disease
Published
2018-11
Volume
10
Issue
S30
Pages
S3629-S3636
ISSN
  • 2072-1439 (ISSN-L)
  • 2077-6624
OpenAlex
W2883298631
Cited by
69
References
7
FWCI
6.19
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Valve durability after transcatheter aortic valve implantation. https://app.cochat.ai/papers/10.21037/jtd.2018.07.38
The paper
Kataruka, A., & Otto, C. M. (2018). Valve durability after transcatheter aortic valve implantation. Journal of Thoracic Disease. https://doi.org/10.21037/jtd.2018.07.38

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.