A multicenter study of the treatment of non-union with constant direct current.

Brighton, C T, Black, J, Friedenberg, Z B, Esterhai, J L, Day, L J, Connolly, J F·1981·The Journal of Bone & Joint Surgery

Abstract

A clinical study was initiated at the University of Pennsylvania in 1970 to evaluate the use of constant direct current in treating acquired non-union. In 1977 the study was expanded to include twelve participating investigators throughout the United States. The results indicate that, given proper electrical parameters and proper cast immobilization, a rate of bone union comparable to that seen with bone-graft surgery was achieved. Experience dictated that four cathodes, each delivering twenty microamperes of constant direct current for twelve weeks, were required to heal a non-union of a long bone. Of 178 non-union in 175 patients treated with adequate electricity in the University of Pennsylvania series, 149 (83.7 per cent) achieved solid bone union. Patients with a history of osteomyelitis had a healing rate of 74.4 per cent. The presence of previously inserted metallic fixation devices did not affect the end-result healing rate. Of eighty non-unions in seventy-nine patients treated with electricity in the participating investigators' series, fifty-eight (72.5 per cent) achieved solid bone union. Review of the non-unions treated unsuccessfully with constant direct current suggested that inadequate electricity, the presence of synovial pseudarthrosis or infection, and dislodgment of the electrodes are causes for failure with the procedure. Complications of the electrical treatment were minor and there was no deep infection resulting from this procedure in patients without previous osteomyelitis. We concluded that the practicing orthopaedic surgeon utilizing constant direct current to treat non-union should, by adhering to proper fracture management and by following the biophysical principles described herein, be able to achieve a rate of union comparable to that of bone-graft surgery, with a lower associated risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-198163010-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 254

Metadata

Authors
Brighton, C. T., Black, J., Friedenberg, Z. B., Esterhai, J. L., Day, L. J., & Connolly, J. F.
Venue
The Journal of Bone & Joint Surgery
Published
1981-01
Volume
63
Issue
1
Pages
2-13
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1902122412
Cited by
254
References
0
FWCI
13.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multicenter study of the treatment of non-union with constant direct current. https://app.cochat.ai/papers/10.2106/00004623-198163010-00002
The paper
Brighton, C. T., Black, J., Friedenberg, Z. B., Esterhai, J. L., Day, L. J., & Connolly, J. F. (1981). A multicenter study of the treatment of non-union with constant direct current. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198163010-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.