Performance of the tibial component in total knee replacement.
The DOI matches its Crossref record.
Abstract
UNLABELLED: In patients with deficient bone in the proximal end of the tibia, the mechanical support of a conventional total knee replacement may be inadequate. We have developed a custom design for use in situations in which there is extensive deficiency of tibial cancellous bone. To do this, we examined conventional and custom prosthetic tibial components using finite-element analysis. Several loading configurations were tested, and the worst loading conditions were found to be those in which eccentric loads were placed on the margin of the tibial component. The results showed that the stresses on the cancellous bone beneath a conventional-design prosthesis may be lowered if a metal tray and metal peg are employed. A salvage-design concept for revision in the presence of deficient cancellous bone was tested analytically and used successfully. This concept requires that some portion of the applied load be transferred directly to the tibial cortical shell. Stresses in the remaining cancellous bone were lowered by the combination of a thickened metal tray and a metal support buttress. CLINICAL RELEVANCE: This study demonstrates the advantage of metal trays for the tibial plateau and suggests that they should be used whenever the supporting tibial bone is insufficient. In knees in which there are large defects in the bone, direct transfer of the load to the cortical shell through the prosthesis, made possible by a custom design, appears to be necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539
FACTORS AFFECTING THE DURABILITY OF PRIMARY TOTAL KNEE PROSTHESES
RAND, J. A., TROUSDALE, R. T., ILSTRUP, D. M., & HARMSEN, W. S. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200302000-00012 · Cited by 471
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Current Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
Metadata
- Authors
- Bartel, D. L., Burstein, A. H., Santavicca, E. A., & Insall, J. N.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1982-09
- Volume
- 64
- Issue
- 7
- Pages
- 1026-1033
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1945492832
- Cited by
- 265
- References
- 0
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of the tibial component in total knee replacement. https://app.cochat.ai/papers/10.2106/00004623-198264070-00009
- The paper
- Bartel, D. L., Burstein, A. H., Santavicca, E. A., & Insall, J. N. (1982). Performance of the tibial component in total knee replacement. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198264070-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.