The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis.
Open accessAbstract
UNLABELLED: The membrane present at the bone-cement interface was retrieved from twenty patients with a loose, non-septic failed total hip replacement at a site clearly remote from the pseudocapsule that reformed postoperatively. The orientation of the membrane was carefully marked to identify the surface in contact with cement. The membrane was studied histologically, histochemically, by cell culture, by organ culture, and by assessment of its ability to synthesize prostaglandin E2 and collagenase. This membrane, rather than being a nondescript so-called fibrous membrane, has the histological and histochemical characteristics of a synovial-like lining. The synovial-like cells are adjacent to the cement layer. Deep to them macrophages predominate. Inflammatory cells are absent. Cell cultures of this membrane contain stellate cells similar to those found in cell cultures of normal and rheumatoid synovial tissue. This membrane has the capacity to produce large amounts of prostaglandin E2 and collagenase. CLINICAL RELEVANCE: This transformation of tissue at the bone-cement interface in patients with a non-septic, loose total hip component to a synovial-like tissue with the capacity to generate prostaglandin E2 and collagenase may explain the progressive lysis of bone that is seen in some patients with loose cemented total joint implants. Loosening of the component may be a stimulus to the synthetic activity of this tissue, which leads to further resorption of bone. Understanding and the possibility of pharmacological control of this membrane may contribute to improved duration of total joint implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
The expression of osteoclast markers on foreign body giant cells
Kadoya, Y., Al-Saffar, N., Kobayashi, A., & Revell, P. A. (1994) · Bone and Mineral · doi:10.1016/s0169-6009(08)80211-5 · Cited by 87
Mevoy, A., Jeyam, M., Ferrier, G., Evans, C. E., & Andrew, J. G. (2002) · Bone · doi:10.1016/s8756-3282(01)00658-5 · Cited by 71
AL-SAFFAR, N., REVELL, P. A., & KOBAYASHI, A. (1997) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1018575504518 · Cited by 38
Metadata
- Authors
- Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1983-06
- Volume
- 65
- Issue
- 5
- Pages
- 575-584
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1957982496
- Cited by
- 849
- References
- 0
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.