The aim of this study was to investigate the effect of the rigidity of external fixation on osteotomy healing based on radiographic, morphological, histological, and biomechanical analyses of canine tibial osteotomies treated with more rigid (six half-pins) and less rigid (four half-pins) unilateral external fixators. Successful healing was obtained in all tibiae, but the bone-healing mechanisms appeared to be different depending on the rigidity of the device used. On the side with more rigid fixation, early clinical union was observed thirty days after osteotomy. Periosteal callus formation was significantly increased on the less rigidly fixed side at both ninety and 120 days (p less than 0.05). Fixation stiffness was found to affect the incidence of pin loosening (p less than 0.01) and of bone porosity (p less than 0.05) at the osteotomy site. However, new-bone formation and the structural strength of the bone were not significantly different between the four-pin and six-pin sides. These results seem to indicate that a longer period is required for fracture repair and remodeling when external fixation with less rigidity is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705
Influence of size and stability of the osteotomy gap on the success of fracture healing
Claes, L., Augat, P., Suger, G., & Wilke, H. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150414 · Cited by 549
The initial phase of fracture healing is specifically sensitive to mechanical conditions
Klein, P., Schell, H., Streitparth, F., Heller, M., Kassi, J., Kandziora, F., Bragulla, H., Haas, N. P., & Duda, G. N. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00259-0 · Cited by 270
Enhancement of Fracture Healing by Low Intensity Ultrasound
Hadjiargyrou, M., McLeod, K., Ryaby, J. P., & Rubin, C. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00022 · Cited by 240
Effect of dynamization on gap healing of diaphyseal fractures under external fixation
Claes, L., Wilke, H.-J., Augat, P., Rübenacker, S., & Margevicius, K. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)99799-8 · Cited by 237
The role of fixator frame stiffness in the control of fracture healing. An experimental study
Goodship, A. E., Watkins, P. E., Rigby, H. S., & Kenwright, J. (1993) · Journal of Biomechanics · doi:10.1016/s0021-9290(05)80002-8 · Cited by 171
“metry and the subsequent pattern of fracture healing (Gilbert et al., 1989; Terjesen and Johnson, 1986; Williams et al., 1987; Wu et al., 1984).”
BackgroundPHIEFFER, L. S., & GOULET, J. A. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200601000-00026 · Cited by 162
Claes, L., Blakytny, R., Besse, J., Bausewein, C., Ignatius, A., & Willie, B. (2011) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181e3d994 · Cited by 75
Metadata
- Authors
- Wu, J. J., Shyr, H. S., Chao, E. Y., & Kelly, P. J.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1984-10
- Volume
- 66
- Issue
- 8
- Pages
- 1258-1264
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1783046765
- Cited by
- 199
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.