The initial phase of fracture healing is specifically sensitive to mechanical conditions

Klein, Petra, Schell, Hanna, Streitparth, Florian, Heller, Markus, Kassi, Jean‐Pierre, Kandziora, Frank, Bragulla, Hermann, Haas, Norbert P., Duda, Georg N. · 2003 · Journal of Orthopaedic Research

Abstract

Interfragmentary movements affect the quality and quantity of callus formation. The mounting plane of monolateral external fixators may give direction to those movements. Therefore, the aim of this study was to determine the influence of the fixator mounting plane on the process of fracture healing. Identically configured fixators were mounted either medially or anteromedially on the tibiae of sheep. Interfragmentary movements and ground reaction forces were evaluated in vivo during a nine week period. Histomorphological and biomechanical parameters described the bone healing processes. Changing only the mounting plane led to a modification of interfragmentary movements in the initial healing phase. The difference in interfragmentary movements between the groups was only significant during the first post‐operative period. However, these initial differences in mechanical conditions influenced callus tissue formation significantly. The group with the anteromedially mounted fixator, initially showing significantly more interfragmentary movements, ended up with a significantly smaller callus diameter and a significantly higher callus stiffness as a result of advanced fracture healing. This demonstrates that the initial phase of healing is sensitive to mechanical conditions and influences the course of healing. Therefore, initial mechanical stability of an osteosynthesis should be considered an important factor in clinical fracture treatment. © 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0736-0266(02)00259-0

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 270

Metadata

Authors
Klein, P., Schell, H., Streitparth, F., Heller, M., Kassi, J., Kandziora, F., Bragulla, H., Haas, N. P., & Duda, G. N.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2003-07
Volume
21
Issue
4
Pages
662-669
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2083407704
Cited by
270
References
29
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The initial phase of fracture healing is specifically sensitive to mechanical conditions. https://app.cochat.ai/papers/10.1016/s0736-0266(02)00259-0
The paper
Klein, P., Schell, H., Streitparth, F., Heller, M., Kassi, J., Kandziora, F., Bragulla, H., Haas, N. P., & Duda, G. N. (2003). The initial phase of fracture healing is specifically sensitive to mechanical conditions. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(02)00259-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.