Abstract
A pressure-measuring Moore-type endoprosthesis was implanted in a seventy-three-year-old patient who had sustained a displaced fracture of the femoral neck. The measurement and telemetry of contact pressures in the hip began in the operating room, and data were acquired periodically for more than thirty-six months. Unexpectedly high localized contact pressures between the acetabular cartilage and the prosthesis were recorded. Early in the period of recovery, activities such as using a bedpan or performing isometric exercise produced pressures that were close to those recorded during normal walking. The highest pressure, eighteen megapascals, was recorded one year postoperatively, while the patient was rising from a chair. High pressures occurred in the superior and posterior aspects of the acetabulum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kinesiology of the Hip: A Focus on Muscular Actions
Neumann, D. A. (2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.3025 · Cited by 727
An in vitro investigation of the acetabular labral seal in hip joint mechanics
Ferguson, S. J., Bryant, J. T., Ganz, R., & Ito, K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00365-2 · Cited by 629
Functional Tissue Engineering: The Role of Biomechanics
Butler, D. L., Goldstein, S. A., & Guilak, F. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1318906 · Cited by 624
Beaupré, G. S., Orr, T. E., & Carter, D. R. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080507 · Cited by 469
Recent Progress in Cartilage Lubrication
Lin, W., & Klein, J. (2021) · Advanced Materials · doi:10.1002/adma.202005513 · Cited by 446
Supramolecular synergy in the boundary lubrication of synovial joints
Seror, J., Zhu, L., Goldberg, R., Day, A. J., & Klein, J. (2015) · Nature Communications · doi:10.1038/ncomms7497 · Cited by 355
The role of strength in rising from a chair in the functionally impaired elderly
Hughes, M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00083-8 · Cited by 345
Athanasiou, K. A., Agarwal, A., & Dzida, F. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120306 · Cited by 343
Torzilli, P. A., Grigiene, R., Borrelli, J., & Helfet, D. L. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835070 · Cited by 326
Mechanics of a constrained chair-rise
Riley, P. O., Schenkman, M. L., Mann, R. W., & Hodge, W. A. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90328-k · Cited by 304
Self-citationElder, B. D., & Athanasiou, K. A. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0435 · Cited by 267
Acetabular Retroversion is Associated With Osteoarthritis of the Hip
Giori, N. J., & Trousdale, R. T. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000093014.90435.64 · Cited by 249
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
D'Lima, D. D., Patil, S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 231
“Subsequently, in vivo forces have been successfully measured in orthopedics in the hip using telemetry links [2-11], spine [12-14], and femur [15-18].”
BackgroundHuang, C.-Y., Mow, V. C., & Ateshian, G. A. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392316 · Cited by 229
The effects of matrix compression on proteoglycan metabolism in articular cartilage explants
Guilak, F., Meyer, B. C., Ratcliffe, A., & Mow, V. C. (1994) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(05)80059-7 · Cited by 227
In vitro models for the study of osteoarthritis
Johnson, C. I., Argyle, D. J., & Clements, D. N. (2016) · The Veterinary Journal · doi:10.1016/j.tvjl.2015.07.011 · Cited by 220
“…passing through the load-323 bearing region of a human acetabular prosthesis has been determined to be approximately 3.5 324 MPa during locomotion (Hodge et al. 1989), and the articular contact pressure of the human 325 knee does not exceed 8 MPa, even when the menisci have been removed…”
BackgroundInfluentialBiomechanical topography of human ankle cartilage
Athanasiou, K. A., Niederauer, G. G., & Schenck, R. C. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584467 · Cited by 216
“Biomechanically related factors that lead to cartilage damage or degeneration have been shown to include increased stresses on the cartilage (1,12), low-contact or noncontact (loading) regions on the joint surface (5,7), or use and disuse of certain portions of the joint (10).”
BackgroundCartilage Stresses in the Human Hip Joint
Macirowski, T., Tepic, S., & Mann, R. W. (1994) · Journal of Biomechanical Engineering · doi:10.1115/1.2895693 · Cited by 208
Self-citationChen, S., Fu, P., Wu, H., & Pei, M. (2017) · Cell and Tissue Research · doi:10.1007/s00441-017-2613-0 · Cited by 199
“Evidence indicates the physiological magnitude of stresses in AC (Hodge et al. 1989; Afoke et al. 1987), such as hydrostatic pressure and compression, varied from 3 to 10 MPa with a frequency of 1 Hz (Waters et al.”
BackgroundYoshida, H., Faust, A., Wilckens, J., Kitagawa, M., Fetto, J., & Chao, E. Y.-S. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.06.026 · Cited by 199
“According to Hodge et al. (1989), the maximum contact pressures were 4.0MPa for walking, 4.5MPa for stair climbing, and 9.7MPa for rising from a chair in 36 months post operation.”
Functional Tissue Engineering: The Role of Biomechanics in Articular Cartilage Repair
Guilak, F., Butler, D. L., & Goldstein, S. A. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200110001-00027 · Cited by 192
Cellular shape and pressure may mediate mechanical control of tissue composition in tendons
Giori, N. J., Beaupré, G. S., & Carter, D. R. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110413 · Cited by 190
Planning Acetabular Redirection Osteotomies Based on Joint Contact Pressures
Hipp, J. A., Sugano, N., Millis, M. B., & Murphy, S. B. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199907000-00018 · Cited by 186
Hartmann, H., Wirth, K., & Klusemann, M. (2013) · Sports Medicine · doi:10.1007/s40279-013-0073-6 · Cited by 179
“9 MPa when rising from a chair [85].”
BackgroundImplantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants
Graichen, F., Arnold, R., Rohlmann, A., & Bergmann, G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886857 · Cited by 173
An implantable telemetry device to measure intra-articular tibial forces
D’Lima, D. D., Townsend, C. P., Arms, S. W., Morris, B. A., & Colwell, C. W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.011 · Cited by 172
“Subsequently, in vivo forces have been successfully measured in orthopedics in the hip using telemetry links (Graichen et al., 1999; Bergmann et al., 1988, 1993; Bassey et al., 1997; Kotzar et al., 1991, 1995; Brand et al., 1994; Graichen and Bergmann, 1991; Davy et al., 1988; Hodge et al., 1989), spine (Calisse et al.”
BackgroundKONRATH, G. A., HAMEL, A. J., OLSON, S. A., BAY, B., & SHARKEY, N. A. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199812000-00008 · Cited by 166
Is staircase walking a risk for the fixation of hip implants?
Bergmann, G., Graichen, F., & Rohlmann, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00105-d · Cited by 164
How severe must repetitive loading be to kill chondrocytes in articular cartilage?
Clements, K. M., Bee, Z. C., Crossingham, G. V., Adams, M. A., & Sharif, M. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0417 · Cited by 152
Metadata
- Authors
- Hodge, W. A., Carlson, K. L., Fijan, R. S., Burgess, R. G., Riley, P. O., Harris, W. H., & Mann, R. W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1989-10
- Volume
- 71
- Issue
- 9
- Pages
- 1378-1386
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1921722373
- Cited by
- 335
- References
- 0
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.