Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption.

Horowitz, S M, Doty, S B, Lane, J M, Burstein, A H·1993·The Journal of Bone & Joint Surgery

Abstract

The purpose of this study was to examine the relationship between the mechanical failure of polymethylmethacrylate and bone resorption at the bone-cement interface of a prosthesis. Evaluation of tissue that had been retrieved from the cement-bone interface of eighteen femoral components of total hip prostheses that were loose without associated infection revealed that a critical factor associated with bone resorption was the presence of particles that were small enough (one to twelve micrometers) to be phagocytized by macrophages. To study this phenomenon in vitro, macrophages in tissue culture were exposed to three preparations of polymethylmethacrylate cement. A novel method of cement preparation was used with control for solid and soluble contaminants, which provided a sensitive and specific technique for the determination of which mediators were released from the macrophages. Electron microscopy demonstrated phagocytosis of particles of less than twelve micrometers in size, regardless of the type of cement preparation. Exposure to all three cement preparations resulted in toxicity, as reflected by inhibition of 3H-thymidine incorporation. Exposure also led to increased release of tumor necrosis factor, but none of the three preparations resulted in release of prostaglandin E2. Division of the cement preparations into two groups on the basis of the size of the particles demonstrated that exposure to particles that were small enough to be phagocytized led to inhibition of 3H-thymidine incorporation and release of tumor necrosis factor, while exposure to particles that were too large to be phagocytized did not. Neither exposure to small particles nor exposure to large particles of cement led to release of prostaglandin E2. Our results show that when the mechanical failure of cement produces particles that are small enough to be phagocytized, phagocytosis of the particles results in the increased production of tumor necrosis factor by the macrophages, which may in turn lead to bone resorption and prosthetic loosening. These small particles also decrease 3H-thymidine uptake by the macrophages.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199306000-00002

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 286

Metadata

Authors
Horowitz, S. M., Doty, S. B., Lane, J. M., & Burstein, A. H.
Venue
The Journal of Bone & Joint Surgery
Published
1993-06
Volume
75
Issue
6
Pages
802-813
ISSN
0021-9355 (ISSN-L)
OpenAlex
W65922439
Cited by
286
References
20
FWCI
18.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption. https://app.cochat.ai/papers/10.2106/00004623-199306000-00002
The paper
Horowitz, S. M., Doty, S. B., Lane, J. M., & Burstein, A. H. (1993). Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199306000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.