The DOI matches its Crossref record.
Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings.
Open accessAbstract
Migration of solid corrosion products from the modular head-neck junction of fifteen total hip replacements to the periprosthetic tissues was studied. The devices and tissues were recovered at the time of a revision procedure or at autopsy after a mean of sixty-four months (range, eight to ninety-seven months). The prostheses had a cobalt-chromium-alloy head coupled with a cobalt-chromium-alloy or a titanium-alloy stem. The solid corrosion product was identified by electron microprobe analysis and Fourier transform infrared microprobe spectroscopy as a chromium orthophosphate hydrate-rich material. The product was present at the junction of the modular head and neck and as particles within the periprosthetic tissues as early as eight months postoperatively. In several hips, it was also present on the polyethylene bearing surface. The particles in the tissues ranged in size from less than one to 500 micrometers. They were present within histiocytes or were surrounded by foreign-body giant cells in the pseudocapsule of the hip joint; in the membranes of the femoral bone-implant interface; and at sites of femoral endosteal erosions, with and without loosening of the femoral component.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Corrosion of Metallic Biomaterials: A Review
Eliaz, N. (2019) · Materials · doi:10.3390/ma12030407 · Cited by 984
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Self-citationMacrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10106 · Cited by 280
Self-citation
Metadata
- Authors
- Urban, R. M., Jacobs, J. J., Gilbert, J. L., & Galante, J. O.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1994-09
- Volume
- 76
- Issue
- 9
- Pages
- 1345-1359
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W203185082
- Cited by
- 337
- References
- 0
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. https://app.cochat.ai/papers/10.2106/00004623-199409000-00009
- The paper
- Urban, R. M., Jacobs, J. J., Gilbert, J. L., & Galante, J. O. (1994). Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199409000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.