The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Corrosion of Metallic Biomaterials: A Review
Open accessAbstract
Metallic biomaterials are used in medical devices in humans more than any other family of materials. The corrosion resistance of an implant material affects its functionality and durability and is a prime factor governing biocompatibility. The fundamental paradigm of metallic biomaterials, except biodegradable metals, has been “the more corrosion resistant, the more biocompatible.” The body environment is harsh and raises several challenges with respect to corrosion control. In this invited review paper, the body environment is analysed in detail and the possible effects of the corrosion of different biomaterials on biocompatibility are discussed. Then, the kinetics of corrosion, passivity, its breakdown and regeneration in vivo are conferred. Next, the mostly used metallic biomaterials and their corrosion performance are reviewed. These biomaterials include stainless steels, cobalt-chromium alloys, titanium and its alloys, Nitinol shape memory alloy, dental amalgams, gold, metallic glasses and biodegradable metals. Then, the principles of implant failure, retrieval and failure analysis are highlighted, followed by description of the most common corrosion processes in vivo. Finally, approaches to control the corrosion of metallic biomaterials are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Following implantation of biomaterials and medical devices, the following sequence of local events takes place: injury, blood-material interactions, provisional matrix formation, acute inflammation, chronic inflammation, granulation tissue development, foreign-body reaction (FBR) and fibrosis (fibrous capsule developm…”
BackgroundSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Non-crystalline Structure in Solidified Gold–Silicon Alloys
KLEMENT, W., WILLENS, R. H., & DUWEZ, P. (1960) · Nature · doi:10.1038/187869b0 · Cited by 2,808
Evolution of nanoporosity in dealloying
Erlebacher, J., Aziz, M. J., Karma, A., Dimitrov, N., & Sieradzki, K. (2001) · Nature · doi:10.1038/35068529 · Cited by 2,753
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
An overview of nitinol medical applications
Duerig, T., Pelton, A., & Stöckel, D. (1999) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(99)00294-4 · Cited by 1,628
Brunette, D. M., Tengvall, P., Textor, M., & Thomsen, P. (2001) · Engineering Materials · doi:10.1007/978-3-642-56486-4 · Cited by 1,547
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Self-citationNew Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Cited by
Svetlizky, D., Das, M., Zheng, B., Vyatskikh, A. L., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2021) · Materials Today · doi:10.1016/j.mattod.2021.03.020 · Cited by 1,371
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Laser-based directed energy deposition (DED-LB) of advanced materials
Svetlizky, D., Zheng, B., Vyatskikh, A., Das, M., Bose, S., Bandyopadhyay, A., Schoenung, J. M., Lavernia, E. J., & Eliaz, N. (2022) · Materials Science and Engineering: A · doi:10.1016/j.msea.2022.142967 · Cited by 331
Self-citationTitanium–Tissue Interface Reaction and Its Control With Surface Treatment
Hanawa, T. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00170 · Cited by 284
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Metadata
- Authors
- Eliaz, N.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2019-01-28
- Volume
- 12
- Issue
- 3
- Pages
- 407
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2913840193
- Cited by
- 984
- References
- 74
- FWCI
- 32.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corrosion of Metallic Biomaterials: A Review. https://app.cochat.ai/papers/10.3390/ma12030407
- The paper
- Eliaz, N. (2019). Corrosion of Metallic Biomaterials: A Review. Materials. https://doi.org/10.3390/ma12030407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.