The Outcome and Repair Integrity of Completely Arthroscopically Repaired Large and Massive Rotator Cuff Tears
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The impact of a recurrent defect on the outcome after rotator cuff repair has been controversial. The purpose of this study was to evaluate the functional and anatomic results after arthroscopic repair of large and massive rotator cuff tears with use of ultrasound as an imaging modality to determine the postoperative integrity of the repair. METHODS: Eighteen patients who had complete arthroscopic repair of a tear measuring >2 cm in the transverse dimension were evaluated at a minimum of twelve months after surgery and again at two years after surgery. The evaluation consisted of a standardized history and physical examination as well as calculation of the preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons. The strength of both shoulders was quantitated postoperatively with use of a portable dynamometer. Ultrasound studies were performed with use of an established and validated protocol at a minimum of twelve months after surgery. RESULTS: Recurrent tears were seen in seventeen of the eighteen patients. Despite the absence of healing at twelve months after surgery, thirteen patients had an American Shoulder and Elbow Surgeons score of >/=90 points. Sixteen patients had an improvement in the functional outcome score, which increased from an average of 48.3 to 84.6 points. Sixteen patients had a decrease in pain, and twelve had no pain. Although eight patients had preoperative forward elevation to <95 degrees, all eighteen regained motion above shoulder level and had an average of 152 degrees of elevation. At the second evaluation, a minimum of twenty-four months after surgery, the average score, according to the system of the American Shoulder and Elbow Surgeons, had decreased to 79.9 points; only nine patients had a score of >/=90 points, and six patients had a score of </=79 points. The average forward elevation decreased to 142 degrees. CONCLUSIONS: Arthroscopic repair of large and massive rotator cuff tears led to a high percentage of recurrent defects. The minimum twelve-month evaluation showed excellent pain relief and improvement in the ability to perform activities of daily living despite the high rate of recurrent defects; however, at a minimum follow-up of two years, the results deteriorated with only twelve patients who had an American Shoulder and Elbow Surgeons score of >/=80.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A standardized method for the assessment of shoulder function
Richards, R. R., An, K.-N., Bigliani, L. U., Friedman, R. J., Gartsman, G. M., Gristina, A. G., Iannotti, J. P., Mow, V. C., Sidles, J. A., & Zuckerman, J. D. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80019-0 · Cited by 1,726
Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff.
Harryman, D. T., Mack, L. A., Wang, K. Y., Jackins, S. E., Richardson, M. L., & Matsen, F. A. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173070-00004 · Cited by 1,259
Results of a second attempt at surgical repair of a failed initial rotator-cuff repair.
DeOrio, J. K., & Cofield, R. H. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466040-00011 · Cited by 919
Yamaguchi, K., Tetro, A. M., Blam, O., Evanoff, B. A., Teefey, S. A., & Middleton, W. D. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.113086 · Cited by 635
Self-citationFunctional and Anatomical Results After Rotator Cuff Repair
Gazielly, D. F., Gleyze, P., & Montagnon, C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00009 · Cited by 549
Clinical Outcome After Structural Failure of Rotator Cuff Repairs*
JOST, B., PFIRRMANN, C. W. A., & GERBER, C. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200003000-00002 · Cited by 526
Teefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200004000-00005 · Cited by 514
Self-citationArthroscopic Repair of Full-Thickness Tears of the Rotator Cuff*
GARTSMAN, G. M., KHAN, M., & HAMMERMAN, S. M. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199806000-00007 · Cited by 446
Teefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · PubMed · Cited by 428
Self-citationSt Pierre, P., Olson, E. J., Elliott, J. J., OʼHair, K. C., McKinney, L. A., & Ryan, J. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199512000-00010 · Cited by 262
Anatomy and dimensions of rotator cuff insertions
Dugas, J. R., Campbell, D. A., Warren, R. F., Robie, B. H., & Millett, P. J. (2002) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2002.126208 · Cited by 207
Cited by
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
National Trends in Rotator Cuff Repair
Colvin, A. C., Egorova, N., Harrison, A. K., Moskowitz, A., & Flatow, E. L. (2012) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.j.00739 · Cited by 742
Electrospun Nanofibers for Regenerative Medicine
Liu, W., Thomopoulos, S., & Xia, Y. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201100021 · Cited by 550
Tendon Healing: Repair and Regeneration
Voleti, P. B., Buckley, M. R., & Soslowsky, L. J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150122 · Cited by 541
Mulieri, P., Dunning, P., Klein, S., Pupello, D., & Frankle, M. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.00912 · Cited by 507
Metadata
- Authors
- Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 2004-02
- Volume
- 86
- Issue
- 2
- Pages
- 219-224
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1863138831
- Cited by
- 2,145
- References
- 11
- FWCI
- 43.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.