Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

THE VARIABILITY OF FEMORAL ROTATIONAL ALIGNMENT IN TOTAL KNEE ARTHROPLASTY

SISTON, ROBERT A., PATEL, JAY J., GOODMAN, STUART B., DELP, SCOTT L., GIORI, NICHOLAS J. · 2005 · The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if navigation systems can improve the accuracy of femoral rotational alignment as compared with that achieved with more traditional techniques involving mechanical guides. The purposes of the present study were to characterize the variability associated with femoral rotational alignment techniques and to determine whether the use of a computer-assisted surgical navigation system reduced this variability. METHODS: Eleven orthopaedic surgeons used five alignment techniques (including one computer-assisted technique and four traditional techniques) to establish femoral rotational alignment axes on ten cadaveric specimens, and the orientation of these axes was recorded with use of a navigation system. These derived axes were compared against a reference transepicondylar axis on each femur that was established after complete dissection of all soft tissues. RESULTS: There was no difference between the mean errors of all five techniques (p > 0.11). Only 17% of the knees were rotated <5 degrees from the reference transepicondylar axis, with alignment errors ranging from 13 degrees of internal rotation to 16 degrees of external rotation. There were significant differences among the surgeons with regard to their ability to accurately establish femoral rotational alignment axes (p < 0.001). CONCLUSIONS: All techniques resulted in highly variable rotational alignment, with no technique being superior. This variability was primarily due to the particular surgeon who was performing the alignment procedure. A navigation system that relies on directly digitizing the femoral epicondyles to establish an alignment axis did not provide a more reliable means of establishing femoral rotational alignment than traditional techniques did.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200510000-00018

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 252

Metadata

Authors
SISTON, R. A., PATEL, J. J., GOODMAN, S. B., DELP, S. L., & GIORI, N. J.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2005-10
Volume
87
Issue
10
Pages
2276-2280
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2106420730
Cited by
252
References
11
FWCI
12.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: THE VARIABILITY OF FEMORAL ROTATIONAL ALIGNMENT IN TOTAL KNEE ARTHROPLASTY. https://app.cochat.ai/papers/10.2106/00004623-200510000-00018
The paper
SISTON, R. A., PATEL, J. J., GOODMAN, S. B., DELP, S. L., & GIORI, N. J. (2005). THE VARIABILITY OF FEMORAL ROTATIONAL ALIGNMENT IN TOTAL KNEE ARTHROPLASTY. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200510000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.