Abstract
BACKGROUND: Bone-healing is known to be sensitive to the mechanical stability of fixation. However, the influence on healing of the individual components of fixation stiffness remains unclear. The aim of this study was to investigate the relationship between the initial in vitro fixation stiffness and the strength and stiffness of the callus after nine weeks. We hypothesized that axial stiffness would determine the healing outcome. METHODS: A standardized midshaft osteotomy of the right tibia was performed on Merino-mix sheep and was stabilized with either one of four monolateral external fixators or one of two tibial nails inserted without reaming. The in vitro stiffness of fixation was determined in six loading conditions (axial compression, torsion, as well as bending and shear in the anteroposterior and mediolateral planes) on ovine tibial specimens. Stiffness was calculated by relating displacements of the fracture fragments, determined by means of attached optical markers, and the loads applied by a materials testing machine. Torsional testing until failure of the explanted tibiae was performed with use of a standard materials testing machine after nine weeks of healing to determine the failure moment and the torsional stiffness of the healed tibia. RESULTS: External fixation in sheep generally resulted in higher fixation stiffness than did conventional unreamed tibial nailing. The use of angle-stable locking screws in tibial nailing resulted in fixation stiffness comparable with that of external fixation. The highest torsional moment to failure was observed for the external fixator with moderate axial stiffness and high shear stiffness. The fixator with the highest axial stability did not result in the highest failure moment. Low axial stability in combination with low shear stability resulted in the lowest failure moment. CONCLUSIONS: In this study, a clear relationship between the stability of fixation and the mechanical strength of the healing tibia was seen. Moderate levels of axial stability were associated with the highest callus strength and stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The influence of induced micromovement upon the healing of experimental tibial fractures
Goodship, A., & Kenwright, J. (1985) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.67b4.4030869 · Cited by 903
Shear movement at the fracture site delays healing in a diaphyseal fracture model
Augat, P., Burger, J., Schorlemmer, S., Henke, T., Peraus, M., & Claes, L. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00098-6 · Cited by 369
A model for intramembranous ossification during fracture healing
Thompson, Z., Miclau, T., Hu, D., & Helms, J. A. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00017-7 · Cited by 277
The initial phase of fracture healing is specifically sensitive to mechanical conditions
Klein, P., Schell, H., Streitparth, F., Heller, M., Kassi, J., Kandziora, F., Bragulla, H., Haas, N. P., & Duda, G. N. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00259-0 · Cited by 270
Self-citationMolecular aspects of healing in stabilized and non‐stabilized fractures
Le, A. X., Miclau, T., Hu, D., & Helms, J. A. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(00)00006-1 · Cited by 240
The four biomechanical stages of fracture repair
White, A., Panjabi, M., & Southwick, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759020-00009 · Cited by 208
THE BIOMECHANICS OF FRACTURE HEALING
Yamagishi, M., & Yoshimura, Y. (1955) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195537050-00013 · Cited by 195
The role of fixator frame stiffness in the control of fracture healing. An experimental study
Goodship, A. E., Watkins, P. E., Rigby, H. S., & Kenwright, J. (1993) · Journal of Biomechanics · doi:10.1016/s0021-9290(05)80002-8 · Cited by 171
The Influence of Active Shear or Compressive Motion on Fracture-Healing*
PARK, S.-H., OʼCONNOR, K., MCKELLOP, H., & SARMIENTO, A. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199806000-00011 · Cited by 160
The use of the Hickman catheter in orthopaedic infections. Brief note.
BERMAN, A. T., & Johnson, M. D. (1985) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198567040-00028 · Cited by 140
Interfragmentary Motion in Tibial Osteotomies Stabilized With Ring Fixators
Duda, G. N., Sollmann, M., Sporrer, S., Hoffmann, J. E., Kassi, J.-P., Khodadadyan, C., & Raschke, M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200203000-00025 · Cited by 89
Self-citationShear Does Not Necessarily Inhibit Bone Healing
Bishop, N. E., van Rhijn, M., Tami, I., Corveleijn, R., Schneider, E., & Ito, K. (2006) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000191272.34786.09 · Cited by 88
Klein, P., Opitz, M., Schell, H., Taylor, W. R., Heller, M. O. W., Kassi, J., Kandziora, F., & Duda, G. N. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.02.006 · Cited by 71
Self-citationDuda, G. N., Sporrer, S., Sollmann, M., Hoffmann, J. E., Kassi, J., Khodadadyan, C., & Raschke, M. J. (2003) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-002-0340-8 · Cited by 58
Self-citationThe influence of external fixators on fracture motion during simulated walking
Gardner, T., Evans, M., & KENWRIGHT, J. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00056-9 · Cited by 36
Kassi, J., Hoffmann, J.-E., Heller, M. O. W., Raschke, M. J., & Duda, G. N. (2001) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2001.46.9.247 · Cited by 27
Self-citationTerjesen, T., & Johnson, E. (1986) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678609000889 · Cited by 25
Mechanical Performance of an Axially Mobile Plate for Fracture Fixation
Sun, J., Abel, E. W., & ROWLEY, D. I. (1998) · doi:10.1097/00005373-199802000-00024 · Cited by 5
Cited by
Fracture healing under healthy and inflammatory conditions
Claes, L., Recknagel, S., & Ignatius, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.1 · Cited by 1,326
Malhotra, A., Walle, M., Paul, G. R., Kuhn, G. A., & Müller, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-81132-8 · Cited by 828
Inflammatory phase of bone healing initiates the regenerative healing cascade
Schmidt-Bleek, K., Schell, H., Schulz, N., Hoff, P., Perka, C., Buttgereit, F., Volk, H.-D., Lienau, J., & Duda, G. N. (2012) · Cell and Tissue Research · doi:10.1007/s00441-011-1205-7 · Cited by 284
Self-citationBiomaterial delivery of morphogens to mimic the natural healing cascade in bone
Mehta, M., Schmidt-Bleek, K., Duda, G. N., & Mooney, D. J. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.05.006 · Cited by 246
Self-citationFar Cortical Locking Can Improve Healing of Fractures Stabilized with Locking Plates
Bottlang, M., Lesser, M., Koerber, J., Doornink, J., von Rechenberg, B., Augat, P., Fitzpatrick, D. C., Madey, S. M., & Marsh, J. L. (2010) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.i.01111 · Cited by 239
Metadata
- Authors
- Epari, D. R., Schell, H., Duda, G. N., & Kassi, J.-P.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2007-07
- Volume
- 89
- Issue
- 7
- Pages
- 1575-1585
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1970342160
- Cited by
- 201
- References
- 18
- FWCI
- 5.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.