Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Diagnosis of Periprosthetic Joint Infection: The Utility of a Simple Yet Unappreciated Enzyme

Parvizi, Javad, Jacovides, Christina, Antoci, Valentin, Ghanem, Elie·2011·The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: The white blood-cell count and neutrophil differential of the synovial fluid have been reported to have high sensitivity and specificity in the diagnosis of periprosthetic infection following total knee arthroplasty. We hypothesized that neutrophils recruited into an infected joint secrete enzymes that may be used as markers for infection. In this prospective study, we determined the sensitivity and specificity of one of these enzymes, leukocyte esterase, in diagnosing periprosthetic joint infection. METHODS: Between May 2007 and April 2010, synovial fluid was obtained preoperatively from the knees of patients with a possible joint infection and intraoperatively from the knees of patients undergoing revision knee arthroplasty. The aspirate was tested for the presence of leukocyte esterase with use of a simple colorimetric strip test. The color change (graded as negative, trace, +, or ++), which corresponded to the level of the enzyme, was noted after one or two minutes. RESULTS: On the basis of clinical, serological, and operative criteria, thirty of the 108 knees undergoing revision arthroplasty were infected and seventy-eight were uninfected. When only a ++ reading was considered positive, the leukocyte esterase test was 80.6% sensitive (95% confidence interval [CI], 61.9% to 91.9%) and 100% specific (95% CI, 94.5% to 100.0%), with a positive predictive value of 100% (95% CI, 83.4% to 100.0%) and a negative predictive value of 93.3% (95% CI, 85.4% to 97.2%). The leukocyte esterase level correlated strongly with the percentage of polymorphonuclear leukocytes (r = 0.7769) and total white blood-cell count (r = 0.5024) in the aspirate as well as with the erythrocyte sedimentation rate (r = 0.6188) and C-reactive protein level (r = 0.4719) in the serum. CONCLUSIONS: The simple colorimetric strip test that detects the presence of leukocyte esterase in synovial fluid appears to be an extremely valuable addition to the physician's armamentarium for the diagnosis of periprosthetic joint infection. The leukocyte esterase reagent strip has the advantages of providing real-time results, being simple and inexpensive, and having the ability to both rule out and confirm periprosthetic joint infection. However, additional multicenter studies are required to substantiate the results of our preliminary investigation before the reagent strip can be used confidently in the clinic or intraoperative setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.j.01413

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 281

Metadata

Authors
Parvizi, J., Jacovides, C., Antoci, V., & Ghanem, E.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2011-12
Volume
93
Issue
24
Pages
2242-2248
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2074839975
Cited by
281
References
19
FWCI
19.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of Periprosthetic Joint Infection: The Utility of a Simple Yet Unappreciated Enzyme. https://app.cochat.ai/papers/10.2106/jbjs.j.01413
The paper
Parvizi, J., Jacovides, C., Antoci, V., & Ghanem, E. (2011). Diagnosis of Periprosthetic Joint Infection: The Utility of a Simple Yet Unappreciated Enzyme. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/jbjs.j.01413

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.