Visual Colorimetric Determination of Sulfate Ion in Water Using Coprecipitation Phenomenon of Potassium Permanganate and Barium Sulfate
Open accessAbstract
An on-site analytical technique for the colorimetric determination of sulfate ion in a water sample was developed based on the formation of purple precipitates as mixed crystals composed of barium sulfate with permanganate. Potassium permanganate solution and acidic barium chloride solution with hydrochloric acid were added in sequence into 1.5 mL of the sample, then the mixed crystals precipitated and suspended. The residual excess of permanganate ion remaining in the mother solution was reduced with ascorbic acid to turn it colorless. At that time, colors of the suspended precipitates became observable. The intensity of purple color tone of the suspension varied depending on the concentration of sulfate ion. The concentration was determined semi-quantitatively by visual comparison of the intensity with standard color charts. The proposed colorimetry permitted us to determine sulfate ion at the range of 50 to 2000 mg L−1. The time required for the on-site analysis was less than one minute. We applied the colorimetry to the real drainage samples taken from biological desulfurization systems and obtained good results useful for maintenance of them.
AI snapshot
Written from the paper’s full text.
TL;DR
A field-friendly visual colorimetric method for sulfate in water was developed by coprecipitating permanganate with barium sulfate to produce a purple suspension whose intensity reflects sulfate concentration. After excess permanganate is reduced with ascorbic acid, sulfate can be estimated against standard color charts over 50–2000 mg/L in under one minute, and the method was tested on drainage from biological desulfurization systems.
Key findings
- Sulfate is detected through purple mixed crystals/suspended precipitate formed when potassium permanganate and acidic barium chloride are added to a 1.5 mL sample; excess permanganate in the mother liquor is decolorized with ascorbic acid so the precipitate color becomes visible.
- The visual quantification range is 50–2000 mg/L: below 50 mg/L the red color is not visually distinguishable, and above 2000 mg/L the suspension color no longer changes with increasing precipitate. The analysis takes less than 1 minute, and repeated measurements gave a coefficient of variation below 5% (n = 3).
- The method was applied to real drainage samples from biological desulfurization systems and gave results described as useful for maintenance. Table 3 compares it with other colorimetric methods, listing the proposed method as 50–2000 mg/L and <1 min.
- Interference tests showed that hydrochloric acid above 0.10 mol/L lowers the color response, while potassium chloride up to at least 1.0 mol/L has no effect; the method uses pH 2–3, 0.10 mol/L HCl, 2.0 mol/L KCl, 0.20% nonionic surfactant, 50 mg ascorbic acid, 0.20 mL of 40 mmol/L KMnO4, and 0.10 mL of 120 g/L barium chloride dihydrate solution.
Methods
- Design: on-site visual colorimetry using a sealed polyethylene tube (“Packtest”) as both reaction vessel and color-comparison tube, with standard color charts prepared from sulfate standards at 0, 50, 100, 200, 500, 1000, and 2000 mg/L.
- Procedure: add 0.20 mL of 40 mmol/L KMnO4 and 0.10 mL of precipitating reagent containing 120 g/L BaCl2·2H2O, 0.10 mol/L HCl, 2.0 mol/L KCl, and 0.20% polyoxyethylene(10) octylphenyl ether to 1.5 mL sample; then add 50 mg ascorbic acid to reduce residual permanganate; shake and compare visually.
- Analysis: color intensity was also measured as Δa* using a Konica Minolta CM-2600d spectrophotometer with a custom jig; foreign-component effects were tested at 1000 mg/L with sulfate absent or at 200 mg/L (n = 1), defining no effect when blank Δa* < 2.0 and 200 mg/L Δa* fell within 8.0–12.5; real drainage samples came from biological desulfurization systems.
Limitations
- Stated: the method is semi-quantitative and visually limited to 50–2000 mg/L; below 50 mg/L the red color cannot be distinguished, and above 2000 mg/L the color no longer changes with increasing precipitate.
- Stated: the colored suspension settles on standing, so the tube must be shaken again to restore a color comparable to that immediately after reaction.
- Evident: interference testing used n = 1 and a narrow Δa* acceptance window, and the real drainage application is reported only qualitatively in the provided text, without recovery or sample details. Also stated: high HCl/chloride conditions can consume permanganate and lower the response, making pH below 1 unsuitable.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
- Findingreasoning§ Abstract
The intensity of the purple color tone of the suspension varied depending on the concentration of sulfate ion.
“The intensity of purple color tone of the suspension varied depending on the concentration of sulfate ion.”
Quote in the paperSubstantial claim - Findingown data§ 3・2
For the precipitating reagent solution of the above composition, the color development became constant when 0.05 mL or more was added.
“0.05mL 以上の添加で一定となる 結果を得たので,本法では 0.1 mL(点眼瓶で 4 滴に相当, 界面活性剤を含有するので 1 滴当たりの体積が小さい)を 添加することにした.”
Quote in the paperSubstantial claim - Findingown data§ Abstract
The proposed colorimetry permitted determination of sulfate ion in the range of 50 to 2000 mg L-1.
“The proposed colorimetry permitted us to determine sulfate ion at the range of 50 to 2000 mg L -1 .”
- Also stated in: § 3・4 · plain
“すなわち,本法による目視定量範囲は 50 -2000 mg L -1 であった.”
Quote in the paperSubstantial claim - Also stated in: § 3・4 · plain
- Findingnone given§ Abstract
The time required for the on-site analysis was less than one minute.
“The time required for the on-site analysis was less than one minute.”
Quote in the paperSubstantial claim - Findingown data§ 3・2
When the hydrochloric acid concentration in the sample water exceeded 0.10 mol L-1, Δa* tended to decrease.
“その結果,試料水中の塩酸濃度が 0.10 mol L -1 を 超過すると Δa * が低下する傾向を認めた.”
Quote in the paperSubstantial claim
- Interpretationreasoning§ Abstract
The concentration of sulfate ion was determined semi-quantitatively by visual comparison of the intensity with standard color charts.
“The concentration was determined semi-quantitatively by visual comparison of the intensity with standard color charts.”
Quote in the paperSubstantial claim - Interpretationown data§ 3・4
If a standard color series corresponding to the standard solutions was prepared in advance, visual color comparison could rapidly determine an approximate concentration of an unknown sample.
“上記の各標準液 に対応する標準色列をあらかじめ準備しておけば,未知試 料について目視比色により濃度概略値の迅速判定が可能で あった.”
Quote in the paperSubstantial claim - Interpretationown data§ Abstract
An on-site analytical technique for the colorimetric determination of sulfate ion in a water sample was developed based on the formation of purple precipitates as mixed crystals composed of barium sulfate with permanganate.
“An on-site analytical technique for the colorimetric determination of sulfate ion in a water sample was developed based on the formation of purple precipitates as mixed crystals composed of barium sulfate with permanganate.”
Quote in the paperSubstantial claim - Interpretationreasoning§ 3・3
To observe the color tone exhibited by the suspended barium sulfate particles, it was necessary to add a reducing agent to the mother liquor to decolorize the permanganate ion.
“硫酸バリウムの 懸濁粒子が呈する色調を観測するためには,母液中に還元 剤を添加して過マンガン酸イオンを無色化する必要があ る.”
Quote in the paperSubstantial claim
- Classified as probably not a substantial claim. 1
- May combine two claims. 5
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Findingnone given§ 3・4When the suspension in the polyethylene tube was left standing, the colored suspension gradually settled, but shaking the tube again gave a suspension with the same color tone as immediately after reaction.
“なお,ポリエチレン製チューブ内の懸濁液を放置すると 着色懸濁物が徐々に沈降したが,再度チューブを振り混ぜ る操作により反応直後と色調が同等の懸濁液が得られた.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown data§ 3・4Δa* increased depending on the sulfate ion concentration, and the coefficient of variation for repeated measurements was less than 5% (n=3).
“硫酸イオン濃度に依存して Δa * が増加する 結果が得られ,繰り返し測定した場合の変動係数は 5 % 未 満(n=3)であった.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ AbstractThe colorimetry was applied to real drainage samples taken from biological desulfurization systems and obtained good results useful for maintenance of them.
“We applied the colorimetry to the real drainage samples taken from biological desulfurization systems and obtained good results useful for maintenance of them.”
Quote in the paperSubstantial claimMay combine two claims.
Findingreasoning§ 3・3At the time barium sulfate was precipitated, excess permanganate ion remained in the mother liquor, so the reaction solution was deep red regardless of the presence or absence of sulfate ion.
“硫酸バリウムを析出させた時点では,母液中に過剰量の 過マンガン酸イオンが残存しているため,硫酸イオンの有 無にかかわらず反応液は濃紅色を呈した.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown data§ 3・4The visual determination range of the proposed method was 50-2000 mg L-1, because below 50 mg L-1 the red color could not be visually distinguished and above 2000 mg L-1 no color tone change of the suspension was obtained with increased precipitate amount.
“定量範囲について検討した結果,50 mg L -1 未満で は紅色が目視で識別できず,また 2000 mg L -1 以上では微 粒子の析出量増大に伴った懸濁液の色調変化が得られな かった.すなわち,本法による目視定量範囲は 50 -2000 mg L -1 であった.”
Quote in the paperSubstantial claim
Cites
Spot Tests in Inorganic Analysis
Feigl, F., Anger, V., & Koslow, R. H. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403827 · Cited by 329
5) I. Iwasaki, S. Utsumi, K. Hagino, T. Tarutani, T. Ozawa : <i>Bull. Chem. Soc. Jpn.</i>, <b>30</b>, 847 (1957).
(n.d.)
Unresolved6) R. J. Bertolacini, J. E. Barney : <i>Anal. Chem.</i>, <b>29</b>, 281 (1957).
(n.d.)
Unresolved10) P. A. Jones, W. I. Stephen : <i>Anal. Chim. Acta</i>, <b>64</b>, 85 (1973).
(n.d.)
Unresolved15) F. Feigl, V. Anger : “<i>Spot Tests in Inorganic Analysis</i>”, 6th ed., p. 431 (1972), (Elsevier Publishing Company).
(n.d.)
Unresolved16) H. Yagoda : <i>J. Ind. Hyg. Toxicol.</i>, <b>26</b>, 224 (1944).
(n.d.)
Unresolved
Flagged first, then by citations
5 of the 5 references couldn’t be matched to a known paper.
- Authors
- MURAI, K., HONDA, H., & OKAUCHI, S.
- Affiliations
- Kyoritsu Chemical-Check Lab., Corp.
- Venue
- BUNSEKI KAGAKU
- Published
- 2020-06-05
- Volume
- 69
- Issue
- 6
- Pages
- 311-316
- ISSN
- 0525-1931 (ISSN-L)
- OpenAlex
- W3043365952
- Cited by
- 0
- References
- 5
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- BUNSEKI KAGAKU (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Keywords
- colorimetry, potassium permanganate, barium sulfate, co-precipitation, solid solutions, on-site water analysis, ascorbic acid reduction, biodesulfurization, drainage water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-11.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-11.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review