CoChat

Patient satisfaction and costs associated with insulin administered by pen device or syringe during hospitalization

Davis, Estella M., Christensen, Carla M., Nystrom, Kelly K., Foral, Pamela A., Destache, Chris · 2008 · American Journal of Health-System Pharmacy
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: Patient satisfaction, safety and efficacy outcomes, and cost savings with insulin pens versus conventional insulin delivery via vials and syringes in hospitalized patients with diabetes were compared. METHODS: Patients were recruited from two general medical-surgical units from July 2005 to May 2006. Patients completed a survey regarding satisfaction with the method in which insulin was administered before discharge. Patients completed a telephone survey approximately four weeks after discharge to determine home insulin use. Cost savings were determined using the average wholesale price of insulin vials and syringes, pens, and pen needles. RESULTS: A total of 94 patients were randomized to receive insulin administered via pen devices (n = 49) or using conventional vials and syringes (n = 45). Significantly more subjects in the pen group prepared or self-injected at least one dose of insulin during hospitalization, wanted to continue taking insulin at home using the method used during hospitalization, and would recommend their method of insulin administration used during hospitalization to other patients with diabetes compared with the vial and syringe group (p < 0.05). A cost saving of $36 per patient was projected if only insulin pens were dispensed during the entire hospital stay compared to insulin vials and syringes (p < 0.05). CONCLUSION: Increased patient satisfaction and continuation of the method of insulin administration used in the hospital at home were reported by patients who received insulin pens compared with patients who received conventional vials and syringes during hospitalization. A substantial cost saving was projected for patients in the insulin pen group if insulin pens had been dispensed during their entire hospital stay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2146/ajhp070636

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 67

Metadata

Authors
Davis, E. M., Christensen, C. M., Nystrom, K. K., Foral, P. A., & Destache, C.
Venue
American Journal of Health-System Pharmacy
Published
2008-07-15
Volume
65
Issue
14
Pages
1347-1357
ISSN
  • 1079-2082 (ISSN-L)
  • 1535-2900
OpenAlex
W2018316145
Cited by
67
References
2
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.