CoChat

Effect of barcode technology with electronic medication administration record on medication accuracy rates

Seibert, Heather H., Maddox, Ray R., Flynn, Elizabeth A., Williams, Carolyn K. · 2014 · American Journal of Health-System Pharmacy
Cited by 73

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: The effect of barcode-assisted medication administration (BCMA) with electronic medication administration record (eMAR) technology on the occurrence of medication administration errors was evaluated. METHODS: A pretest-posttest nonequivalent comparison group was used to investigate the effect of BCMA-eMAR on the medication administration accuracy rates at two community-based hospitals. Patient care units included three matched pairs in the two hospitals-two medical-surgical, two telemetry, and two rehabilitation units-plus a medical-surgical intensive care unit, an emergency department, and both an inpatient oncology unit and an outpatient oncology service at one of the hospitals. Medication administration accuracy rates were observed and recorded before (phase 1) and approximately 6 and 12 months after (phases 2 and 3, respectively) the implementation of BCMA-eMAR. RESULTS: The overall accuracy rate at hospital 1 increased significantly from phase 1 (89%) to phase 3 (90%) (p = 0.0015); if wrong-time errors are excluded, the accuracy rate improved from 92% in phase 1 to 96% in phase 3 (p = 0.000008). The overall accuracy rate did not change significantly from phase 1 to phase 3 at hospital 2; when wrong-time errors were excluded from consideration, the accuracy rate improved from 93% in phase 1 to 96% in phase 3 (p = 0.015). CONCLUSION: Implementation of BCMA-eMAR in two hospitals was associated with significant increases in total medication accuracy rates in most study units and did not introduce new types of error into the medication administration process. Accuracy rates further improved when wrong-time errors were excluded from analysis. The frequency of errors preventable by BCMA-eMAR decreased significantly in both hospitals after implementation of that technology. BCMA-eMAR and direct observation were more effective than voluntary reporting programs at intercepting and recording errors and preventing them from reaching patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2146/ajhp130332

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 73

Metadata

Authors
Seibert, H. H., Maddox, R. R., Flynn, E. A., & Williams, C. K.
Venue
American Journal of Health-System Pharmacy
Published
2014-02-01
Volume
71
Issue
3
Pages
209-218
ISSN
  • 1079-2082 (ISSN-L)
  • 1535-2900
OpenAlex
W2036379866
Cited by
73
References
5
FWCI
13.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.