Smart implants in orthopedic surgery, improving patient outcomes: a review
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Smart implants are implantable devices that provide not only therapeutic benefits but also have diagnostic capabilities. The integration of smart implants into daily clinical practice has the potential for massive cost savings to the health care system. Applications for smart orthopedic implants have been identified for knee arthroplasty, hip arthroplasty, spine fusion, fracture fixation and others. To date, smart orthopedic implants have been used to measure physical parameters from inside the body, including pressure, force, strain, displacement, proximity and temperature. The measurement of physical stimuli is achieved through integration of application-specific technology with the implant. Data from smart implants have led to refinements in implant design, surgical technique and strategies for postoperative care and rehabilitation. In spite of decades of research, with very few exceptions, smart implants have not yet become a part of daily clinical practice. This is largely because integration of current sensor technology necessitates significant modification to the implants. While the technology underlying smart implants has matured significantly over the last several decades, there are still significant technical challenges that need to be overcome before smart implants become part of mainstream health care. Sensors for next-generation smart implants will be small, simple, robust and inexpensive and will necessitate little to no modification to existing implant designs. With rapidly advancing technology, the widespread implementation of smart implants is near. New sensor technology that minimizes modifications to existing implants is the key to enabling smart implants into daily clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murray, C. J. L., Vos, T., Lozano, R., Naghavi, M., Flaxman, A. D., Michaud, C., Ezzati, M., Shibuya, K., Salomon, J. A., Abdalla, S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61689-4 · Cited by 8,888
Measuring the global burden of disease
Murray, C. J. L., & Lopez, A. D. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1201534 · Cited by 1,818 · cited 1×
“Low back pain and neck pain are the leading causes of disability worldwide.(59,60) After failing conservative care, many”
BackgroundLoading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Orthopedic implants and devices for bone fractures and defects: Past, present and perspective
Kim, T., See, C. W., Li, X., & Zhu, D. (2020) · Engineered Regeneration · doi:10.1016/j.engreg.2020.05.003 · Cited by 307
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Smart implants in fracture care – Only buzzword or real opportunity
Ernst, M., Richards, R. G., & Windolf, M. (2021) · Injury · doi:10.1016/j.injury.2020.09.026 · Cited by 50
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Gait analysis to monitor fracture healing of the lower leg
Warmerdam, E., Orth, M., Pohlemann, T., & Ganse, B. (2023) · Bioengineering · doi:10.3390/bioengineering10020255 · Cited by 47
“proach is, however, not yet established for daily clinical routine today and requires special and more expensive implants [19,20].”
BackgroundConcepts and clinical aspects of active implants for the treatment of bone fractures
Ganse, B., Orth, M., Roland, M., Diebels, S., Motzki, P., Seelecke, S., Kirsch, S.-M., Welsch, F., Andres, A., Wickert, K., et al. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.05.001 · Cited by 37
Metadata
- Authors
- Ledet, E. H., Liddle, B., Kradinova, K., & Harper, S.
- Venue
- Innovation and Entrepreneurship in Health
- Publisher
- Informa UK Limited
- Published
- 2018-08
- Volume
- Volume 5
- Pages
- 41-51
- ISSN
- 2324-5905 (ISSN-L)
- OpenAlex
- W2889107342
- Cited by
- 153
- References
- 3
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.