Immune complement activation is attenuated by surface nanotopography
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The immune complement (IC) is a cell-free protein cascade system, and the first part of the innate immune system to recognize foreign objects that enter the body. Elevated activation of the system from, for example, biomaterials or medical devices can result in both local and systemic adverse effects and eventually loss of function or rejection of the biomaterial. Here, the researchers have studied the effect of surface nanotopography on the activation of the IC system. By a simple nonlithographic process, gold nanoparticles with an average size of 58 nm were immobilized on a smooth gold substrate, creating surfaces where a nanostructure is introduced without changing the surface chemistry. The activation of the IC on smooth and nanostructured surfaces was viewed with fluorescence microscopy and quantified with quartz crystal microbalance with dissipation monitoring in human serum. Additionally, the ability of pre-adsorbed human immunoglobulin G (IgG) (a potent activator of the IC) to activate the IC after a change in surface hydrophobicity was studied. It was found that the activation of the IC was significantly attenuated on nanostructured surfaces with nearly a 50% reduction, even after pre-adsorption with IgG. An increase in surface hydrophobicity blunted this effect. The possible role of the curvature of the nanoparticles for the orientation of adsorbed IgG molecules, and how this can affect the subsequent activation of the IC, are discussed. The present findings are important for further understanding of how surface nanotopography affects complex protein adsorption, and for the future development of biomaterials and blood-contacting devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggarwal, P., Hall, J. B., McLeland, C. B., Dobrovolskaia, M. A., & McNeil, S. E. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.009 · Cited by 1,791 · cited 1×
“The adsorption of plasma proteins to nanoparticles has recently been subject to increased research, largely due to their potential as carriers of pharmaceuticals for targeted drug delivery or as adjuvants in vaccines.(11,12) When nanoparticles in suspension are exposed to plasma or serum, the protein composition as we…”
BackgroundMediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347 · cited 1×
“The activation of the complement system on biomaterial surfaces can be triggered via the classical or alternative pathway.(17) The classical pathway is activated when the complement protein C1 binds to immunoglobulin G (IgG) molecules adsorbed on a surface.”
BackgroundThe role of complement in biomaterial-induced inflammation
Nilsson, B., Ekdahl, K. N., Mollnes, T. E., & Lambris, J. D. (2007) · Molecular Immunology · doi:10.1016/j.molimm.2006.06.020 · Cited by 431
Cited by
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
“Fine tuning of the adsorbed protein activity can be achieved by topographical changes at the nanometer scale, reflected by conformational changes of the adsorbed protein [224].”
BackgroundThe Impact of Nanoparticle Protein Corona on Cytotoxicity, Immunotoxicity and Target Drug Delivery
Corbo, C., Molinaro, R., Parodi, A., Toledano Furman, N. E., Salvatore, F., & Tasciotti, E. (2016) · Nanomedicine · doi:10.2217/nnm.15.188 · Cited by 692
Engineering the next generation of cell-based therapeutics
Bashor, C. J., Hilton, I. B., Bandukwala, H., Smith, D. M., & Veiseh, O. (2022) · Nature Reviews Drug Discovery · doi:10.1038/s41573-022-00476-6 · Cited by 439
Molecular Interaction of Proteins and Peptides with Nanoparticles
Shemetov, A. A., Nabiev, I., & Sukhanova, A. (2012) · ACS Nano · doi:10.1021/nn300415x · Cited by 432
Is Marginal Bone Loss around Oral Implants the Result of a Provoked Foreign Body Reaction?
Albrektsson, T., Dahlin, C., Jemt, T., Sennerby, L., Turri, A., & Wennerberg, A. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12142 · Cited by 314
Metadata
- Authors
- Hulander, M., Lundgren, Berglin, Ohrlander, Lausmaa, & Elwing
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2011-10
- Volume
- 6
- Pages
- 2653
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W1964023538
- Cited by
- 86
- References
- 4
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immune complement activation is attenuated by surface nanotopography. https://app.cochat.ai/papers/10.2147/ijn.s24578
- The paper
- Hulander, M., Lundgren, Berglin, Ohrlander, Lausmaa, & Elwing. (2011). Immune complement activation is attenuated by surface nanotopography. International Journal of Nanomedicine. https://doi.org/10.2147/ijn.s24578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.