The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Size- and charge-dependent non-specific uptake of PEGylated nanoparticles by macrophages
Open accessAbstract
The assessment of macrophage response to nanoparticles is a central component in the evaluation of new nanoparticle designs for future in vivo application. This work investigates which feature, nanoparticle size or charge, is more predictive of non-specific uptake of nanoparticles by macrophages. This was investigated by synthesizing a library of polymer-coated iron oxide micelles, spanning a range of 30-100 nm in diameter and -23 mV to +9 mV, and measuring internalization into macrophages in vitro. Nanoparticle size and charge both contributed towards non-specific uptake, but within the ranges investigated, size appears to be a more dominant predictor of uptake. Based on these results, a protease-responsive nanoparticle was synthesized, displaying a matrix metalloproteinase-9 (MMP-9)-cleavable polymeric corona. These nanoparticles are able to respond to MMP-9 activity through the shedding of 10-20 nm of hydrodynamic diameter. This MMP-9-triggered decrease in nanoparticle size also led to up to a six-fold decrease in nanoparticle internalization by macrophages and is observable by T(2)-weighted magnetic resonance imaging. These findings guide the design of imaging or therapeutic nanoparticles for in vivo targeting of macrophage activity in pathologic states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perez, J. M., O'Loughin, T., Simeone, F. J., Weissleder, R., & Josephson, L. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017773n · Cited by 355
Velluto, D., Demurtas, D., & Hubbell, J. A. (2008) · Molecular Pharmaceutics · doi:10.1021/mp7001297 · Cited by 110
Self-citation
Cited by
The role of surface charge in cellular uptake and cytotoxicity of medical nanoparticles
Fröhlich, E. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s36111 · Cited by 2,484
The Effect of Nanoparticle Size on In Vivo Pharmacokinetics and Cellular Interaction
Hoshyar, N., Gray, S., Han, H., & Bao, G. (2016) · Nanomedicine · doi:10.2217/nnm.16.5 · Cited by 1,990
Progress in tumor-associated macrophage (TAM)-targeted therapeutics
Ngambenjawong, C., Gustafson, H. H., & Pun, S. H. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.04.010 · Cited by 840
Synthetic Nanoparticles for Vaccines and Immunotherapy
Irvine, D. J., Hanson, M. C., Rakhra, K., & Tokatlian, T. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00109 · Cited by 763
Pozzi, D., Colapicchioni, V., Caracciolo, G., Piovesana, S., Capriotti, A. L., Palchetti, S., De Grossi, S., Riccioli, A., Amenitsch, H., & Laganà, A. (2014) · Nanoscale · doi:10.1039/c3nr05559k · Cited by 581
Metadata
- Authors
- Yu, S., Lau, Thomas, Jerome, Dickerson, Giorgio, T., Hubbell, & Maron
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2012-02
- Volume
- 7
- Pages
- 799
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W2158368253
- Cited by
- 171
- References
- 2
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.