DNA-based magnetic nanoparticle assembly acts as a magnetic relaxation nanoswitch allowing screening of DNA-cleaving agents
Abstract
Monodisperse magnetic nanoparticles conjugated with complementary oligonucleotide sequences self-assemble into stable magnetic nanoassemblies resulting in a decrease of the spin-spin relaxation times (T2) of neighboring water protons. When these nanoassemblies are treated with a DNA cleaving agent, the nanoparticles become dispersed, switching the T2 of the solution back to original values. These qualities render the developed nanoparticles and their nanoassemblies as magnetic relaxation switches capable of screening for DNA-cleaving compounds by magnetic resonance methods such as MRI and NMR.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,273 · see citing works
The Role of DNA Methylation in Mammalian Epigenetics
Jones, P. A., & Takai, D. (2001) · Science · doi:10.1126/science.1063852 · Cited by 2,063 · see citing works
DNA methylation, methyltransferases, and cancer
Robertson, K. D. (2001) · Oncogene · doi:10.1038/sj.onc.1204341 · Cited by 732 · see citing works
DNA Methylation and Epigenetic Inheritance in Plants and Filamentous Fungi
Martienssen, R. A., & Colot, V. (2001) · Science · doi:10.1126/science.293.5532.1070 · Cited by 518 · see citing works
Magnetic Nanosensors for the Detection of Oligonucleotide Sequences
Josephson, L., Pérez, J. M. S., & Weissleder, R. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010903)40:17 · Cited by 379 · see citing works
Self-citationHigh Throughput Magnetic Resonance Imaging for Evaluating Targeted Nanoparticle Probes
Högemann, D., Ntziachristos, V., Josephson, L., & Weissleder, R. (2002) · Bioconjugate Chemistry · doi:10.1021/bc015549h · Cited by 136 · see citing works
Self-citationBiggins, J. B., Prudent, J. R., Marshall, D. J., RUPPEN, M. E., & Thorson, J. S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.240460997 · Cited by 111 · see citing works
Keifer, P. A. (1999) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)80007-x · Cited by 54 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852 · see citing works
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181 · see citing works
Use of magnetic nanoparticles as nanosensors to probe for molecular interactions
Perez, J. M., Josephson, L., & Weissleder, R. (2004) · ChemBioChem · doi:10.1002/cbic.200300730 · Cited by 268 · see citing works
Self-citationBartelle, B. B., Barandov, A., & Jasanoff, A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.4050-15.2016 · Cited by 45 · see citing works
- Authors
- Perez, J. M., O'Loughin, T., Simeone, F. J., Weissleder, R., & Josephson, L.
- Affiliations
- MGH-Center for Molecular Imaging Research, Harvard Medical School, 149 13th Street, Charlestown, Massachusetts 02129
- Harvard University (US)
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-28
- Volume
- 124
- Issue
- 12
- Pages
- 2856-2857
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2010081112
- Cited by
- 355
- References
- 8
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 5 · 2022: 8 · 2021: 5 · 2020: 6 · 2019: 13 · 2018: 12 · 2017: 11 · 2016: 17 · 2015: 13 · 2014: 12 · 2013: 15 · 2012: 27
- FWCI
- 16.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetism in coordination complexes
- Keywords
- magnetic nanoparticles, oligonucleotide conjugation, magnetic relaxation, T2 relaxation time, T2 relaxation, drug screening, nanoparticle dispersion, MRI contrast agents, NMR probes
- MeSH terms
- DNA, Electrophoresis, Oligonucleotides, Viral Proteins, Deoxyribonuclease BamHI, Site-Specific DNA-Methyltransferase (Adenine-Specific), Biosensing Techniques, Nuclear Magnetic Resonance, Biomolecular, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review