The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Intravenous magnetic nanoparticle cancer hyperthermia
Open accessAbstract
Magnetic nanoparticles heated by an alternating magnetic field could be used to treat cancers, either alone or in combination with radiotherapy or chemotherapy. However, direct intratumoral injections suffer from tumor incongruence and invasiveness, typically leaving undertreated regions, which lead to cancer regrowth. Intravenous injection more faithfully loads tumors, but, so far, it has been difficult achieving the necessary concentration in tumors before systemic toxicity occurs. Here, we describe use of a magnetic nanoparticle that, with a well-tolerated intravenous dose, achieved a tumor concentration of 1.9 mg Fe/g tumor in a subcutaneous squamous cell carcinoma mouse model, with a tumor to non-tumor ratio > 16. With an applied field of 38 kA/m at 980 kHz, tumors could be heated to 60°C in 2 minutes, durably ablating them with millimeter (mm) precision, leaving surrounding tissue intact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiotherapy Plus Concomitant and Adjuvant Temozolomide for Glioblastoma
Stupp, R., Mason, W. P., van den Bent, M. J., Weller, M., Fisher, B., Taphoorn, M. J. B., Belanger, K., Brandes, A. A., Marosi, C., Bogdahn, U., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043330 · Cited by 21,807
Dose translation from animal to human studies revisited.
Reagan‐Shaw, S., Nihal, M., & Ahmad, N. (2008) · The FASEB Journal · doi:10.1096/fj.07-9574lsf · Cited by 6,524
Ultra-large-scale syntheses of monodisperse nanocrystals
Park, J., An, K., Hwang, Y., Park, J.-G., Noh, H.-J., Kim, J.-Y., Park, J.-H., Hwang, N.-M., & Hyeon, T. (2004) · Nature Materials · doi:10.1038/nmat1251 · Cited by 4,076
Maeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Cited by
Smart micro/nanoparticles in stimulus-responsive drug/gene delivery systems
Karimi, M., Ghasemi, A., Sahandi Zangabad, P., Rahighi, R., Moosavi Basri, S. M., Mirshekari, H., Amiri, M., Shafaei Pishabad, Z., Aslani, A., Bozorgomid, M., et al. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00798d · Cited by 1,519
Magnetic nanoparticle-based therapeutic agents for thermo-chemotherapy treatment of cancer
Hervault, A., & Thanh, N. T. K. (2014) · Nanoscale · doi:10.1039/c4nr03482a · Cited by 585
Magnetic Nanoparticles in Cancer Theranostics
Gobbo, O. L., Sjaastad, K., Radomski, M. W., Volkov, Y., & Prina-Mello, A. (2015) · Theranostics · doi:10.7150/thno.11544 · Cited by 462
Kandasamy, G., & Maity, D. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.10.058 · Cited by 422
Recent advances in metal nanoparticles in cancer therapy
Sharma, A., Goyal, A. K., & Rath, G. (2018) · Journal of Drug Targeting · doi:10.1080/1061186x.2017.1400553 · Cited by 341
Metadata
- Authors
- Hainfeld, J., & Huang
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2013-07
- Volume
- 8
- Pages
- 2521
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W1484368999
- Cited by
- 245
- References
- 5
- FWCI
- 13.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravenous magnetic nanoparticle cancer hyperthermia. https://app.cochat.ai/papers/10.2147/ijn.s43770
- The paper
- Hainfeld, J., & Huang. (2013). Intravenous magnetic nanoparticle cancer hyperthermia. International Journal of Nanomedicine. https://doi.org/10.2147/ijn.s43770
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.