Choosing the right inhaler for your asthma or COPD patient
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Appropriate selection and correct use of inhalation devices is an integral component in the management of asthma and chronic obstructive pulmonary disease (COPD). It is well known that there are many challenges with the use of inhalers, and no one device suits all patients. Challenges can range from difficulties related to lung disease severity and pulmonary function to physical considerations, including manual dexterity and comorbidities such as arthritis. In terms of device selection and adherence, patient engagement and satisfaction are also important factors to consider. Furthermore, problems with inhaler use can be most evident in children and older patients. Here, we discuss aspects for consideration with commonly used devices, including nebulizers, pressurized metered-dose inhalers, dry powder inhalers, and the soft mist inhaler. As each inhaler offers varying technical properties, a tailored and personalized approach to the selection of the most appropriate device for the patient is highly recommended in order to increase the likelihood of achieving improved disease outcomes and enhance persistence with device adherence. Importantly, education and support is crucial, not only to enable patients to recognize the need for optimal disease management, but also to help them develop good inhaler technique. In addition, health care professionals should also aim to increase their knowledge of the devices they prescribe, and develop systems to ensure that they offer comprehensive support to patients in clinical practice. Considering these aspects, this review discusses potential strategies to help address the challenges of inhaler use in asthma and COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inhaler mishandling remains common in real life and is associated with reduced disease control
Melani, A. S., Bonavia, M., Cilenti, V., Cinti, C., Lodi, M., Martucci, P., Serra, M., Scichilone, N., Sestini, P., Aliani, M., et al. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.005 · Cited by 947
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Self-citationAdherence to inhaled therapy, mortality and hospital admission in COPD
Vestbo, J., Anderson, J. A., Calverley, P. M. A., Celli, B., Ferguson, G. T., Jenkins, C., Knobil, K., Willits, L. R., Yates, J. C., & Jones, P. W. (2009) · Thorax · doi:10.1136/thx.2009.113662 · Cited by 516 · cited 1×
“The detrimental impact of lack of adherence to COPD medication has been well documented by the TOwards a Revolution in COPD Health (TORCH) study, which found it to be significantly associated with increased risk of death and admission to hospital due to exacerbations.(13) In patients with COPD discharged from hospital…”
BackgroundCritical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes
Usmani, O. S., Lavorini, F., Marshall, J., Dunlop, W. C. N., Heron, L., Farrington, E., & Dekhuijzen, R. (2018) · Respiratory Research · doi:10.1186/s12931-017-0710-y · Cited by 402 · cited 1×
“A recent systematic review, however, found 299 descriptions for “critical error”, highlighting the need to achieve a consensus on the definition of an inhaler critical error.(17) It is also recommended that patient preferences for devices should be considered when prescribing an inhaler,(10) but physicians must be cog…”
BackgroundSelf-citationHolding chambers (spacers) versus nebulisers for beta-agonist treatment of acute asthma
Cates, C. J., Welsh, E. J., & Rowe, B. H. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000052.pub3 · Cited by 359
Inhaler competence in asthma: Common errors, barriers to use and recommended solutions
Price, D., Bosnic-Anticevich, S., Briggs, A., Chrystyn, H., Rand, C., Scheuch, G., & Bousquet, J. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2012.09.017 · Cited by 358 · cited 7×
“Patients who believe using their inhaler is an important part of their asthma management demonstrate higher levels of correct inhaler use.(21) However, it is recognized that in addition to understanding the need to use an inhaler for disease control, patients must be educated on the necessity of using it properly.”
BackgroundInfluentialProblems With Inhaler Use: A Call for Improved Clinician and Patient Education
Fink, J. B., & Rubin, B. K. (2005) · Respiratory Care · doi:10.4187/respcare.05501360 · Cited by 358 · cited 1×
“Health care professional-related education The role of the health care professional, whether physician, pharmacist, or other member of the MDT, in inhaler use is central.(7,52) The wide range of drug and inhaler combinations increases the complexity of inhaler choice for physicians, and may also reduce their experienc…”
BackgroundInhaler Errors in the CRITIKAL Study: Type, Frequency, and Association with Asthma Outcomes
Price, D. B., Román-Rodríguez, M., McQueen, R. B., Bosnic-Anticevich, S., Carter, V., Gruffydd-Jones, K., Haughney, J., Henrichsen, S., Hutton, C., Infantino, A., et al. (2017) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2017.01.004 · Cited by 327 · cited 3×
“Common errors for DPIs include not keeping the device in the correct position while loading the dose, failure to tilt head in the correct position, insufficient inspiratory effort, and not emptying lungs before inhalation.(11,21) It is increasingly recognized that many patients with asthma and COPD find difficulty in…”
BackgroundThe History of Therapeutic Aerosols: A Chronological Review
Stein, S. W., & Thiel, C. G. (2017) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2016.1297 · Cited by 309 · cited 1×
“Over the past 30 years, there has been unprecedented growth in the market for inhaled therapy, with annual sales having increased from $7 billion in 1987 to $36 billion in 2014 and with over 90 billion inhaled doses prescribed to patients in a single year.(4) Unlike systemic treatments, inhaled medicines are rapidly d…”
BackgroundCrompton, G. K., Barnes, P. J., Broeders, M., Corrigan, C., Corbetta, L., Dekhuijzen, R., Dubus, J. C., Magnan, A., Massone, F., Sanchis, J., et al. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.01.008 · Cited by 280
Molimard, M., Raherison, C., Lignot, S., Balestra, A., Lamarque, S., Chartier, A., Droz-Perroteau, C., Lassalle, R., Moore, N., & Girodet, P.-O. (2017) · European Respiratory Journal · doi:10.1183/13993003.01794-2016 · Cited by 273 · cited 1×
“1% of patients.(16) A recent systematic review, however, found 299 descriptions for “critical error”, highlighting the need to achieve a consensus on the definition of an inhaler critical error.”
BackgroundInappropriate inhaler use: assessment of use and patient preference of seven inhalation devices
LENNEY, J., INNES, J. A., & CROMPTON, G. K. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0767 · Cited by 266
Objective Assessment of Adherence to Inhalers by Patients with Chronic Obstructive Pulmonary Disease
Sulaiman, I., Cushen, B., Greene, G., Seheult, J., Seow, D., Rawat, F., MacHale, E., Mokoka, M., Moran, C. N., Sartini Bhreathnach, A., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0733oc · Cited by 223 · cited 1×
“function and degree of airways obstruction being key negative influences.(14) It is recognized that a wide range of factors are known to present challenges to patients with respect to inhaler use, including inhalation technique and pulmonary function.”
BackgroundCan all patients with COPD use the correct inhalation flow with all inhalers and does training help?
Al-Showair, R. A. M., Tarsin, W. Y., Assi, K. H., Pearson, S. B., & Chrystyn, H. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.06.008 · Cited by 221 · cited 1×
“It is increasingly recognized that many patients with asthma and COPD find difficulty in generating the necessary optimal inspiratory flow rates for DPIs in order to achieve effective drug delivery and consequent clinical benefit.(41) DPIs are also susceptible to heat and moisture, and special precaution must be taken…”
BackgroundPractical Problems With Aerosol Therapy in COPD
Rau, J. L. (2006) · Respiratory Care · doi:10.4187/respcare.06510158 · Cited by 173 · cited 1×
“Effective use of a DPI requires that each dose is primed and loaded in the correct manner.(40) DPIs derive the energy for emptying the drug system from the user’s inspiratory flow, and the failure to achieve a forceful inspiratory flow through a device is the most common critical mishandling error with DPIs, occurring…”
BackgroundRetail sales of inhalation devices in European countries: So much for a global policy
Lavorini, F., Corrigan, C. J., Barnes, P. J., Dekhuijzen, P. R. N., Levy, M. L., Pedersen, S., Roche, N., Vincken, W., & Crompton, G. K. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.03.012 · Cited by 171
Press, V. G., Arora, V. M., Shah, L. M., Lewis, S. L., Charbeneau, J. T., Naureckas, E. T., & Krishnan, J. A. (2012) · Journal of General Internal Medicine · doi:10.1007/s11606-012-2090-9 · Cited by 165 · cited 1×
“It is also recommended that patient preferences for devices should be considered when prescribing an inhaler,(10) but physicians must be cognizant that patients often overestimate their ability to handle a device correctly.(18) Factors that influence patient preference include simplicity and convenience (eg, size and…”
BackgroundNew Inhaler Devices - The Good, the Bad and the Ugly
Lavorini, F., Fontana, G. A., & Usmani, O. S. (2014) · Respiration · doi:10.1159/000363390 · Cited by 150
Self-citationLoh, C. H., Peters, S. P., Lovings, T. M., & Ohar, J. A. (2017) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201611-903oc · Cited by 143 · cited 1×
“It has been shown that in the acute management of disease, nebulizers produced outcomes that were not significantly different than pMDIs with a spacer;(30) but compared with DPIs, nebulizers may be beneficial in COPD patients with a suboptimal inspiratory flow.(31) A new portable nebulizer (LonhalaTM MagnairTM, Sunovi…”
BackgroundThe importance of inhaler devices in the treatment of COPD
Bonini, M., & Usmani, O. S. (2015) · COPD Research and Practice · doi:10.1186/s40749-015-0011-0 · Cited by 134 · cited 2×
“Each inhaler device also has unique design characteristics, meaning that there is the option to tailor choice to meet the patient’s specific needs.(22) However, it can be appreciated that these factors also present the challenge of ensuring that the patient knows how to use their own device, and that they have suffici…”
BackgroundSelf-citationLevy, M. L., Hardwell, A., McKnight, E., & Holmes, J. (2013) · Primary Care Respiratory Journal · doi:10.4104/pcrj.2013.00084 · Cited by 130 · cited 1×
“Correct inhaler technique is important for optimal delivery of the drug to the lungs and peripheral airways, resulting in greater potential for the achievement of disease control.(36,57,60,61) As treatment efficacy is linked to adherence, addressing patient preferences are essential,(62) and tailored device selection…”
BackgroundInhaler devices in asthma and COPD – An assessment of inhaler technique and patient preferences
Chorão, P., Pereira, A. M., & Fonseca, J. (2014) · Respiratory Medicine · doi:10.1016/j.rmed.2014.04.019 · Cited by 128
Bosnic-Anticevich, S. Z., Chrystyn, H., Costello, R. W., DOLOVICH, M. B., Fletcher, M. J., Lavorini, F., Rodriguez‐Roisin, R., Ryan, D. P., Ming, S. W. Y., & Price, D. B. (2016) · International Journal of COPD · doi:10.2147/copd.s117196 · Cited by 128
Small, M., Anderson, P. E., Vickers, A., Kay, S., & Fermer, S. (2011) · Advances in Therapy · doi:10.1007/s12325-010-0108-4 · Cited by 122
Takaku, Y., Kurashima, K., Ohta, C., Ishiguro, T., Kagiyama, N., Yanagisawa, T., & Takayanagi, N. (2016) · Respiratory Medicine · doi:10.1016/j.rmed.2016.12.012 · Cited by 122
Hodder, R., & Price, D. B. (2009) · International Journal of COPD · doi:10.2147/copd.s3391 · Cited by 121
Lewis, A., Torvinen, S., Dekhuijzen, P. N. R., Chrystyn, H., Watson, A., Blackney, M., & Plich, A. (2016) · BMC Health Services Research · doi:10.1186/s12913-016-1482-7 · Cited by 120 · cited 2×
“Keywords: inhaler, asthma, COPD, adherence Introduction Asthma and chronic obstructive pulmonary disease (COPD) are common chronic conditions that comprise approximately 78% of direct health care costs associated with respiratory diseases in the European Union.1 In the UK alone, 5.4 million patients are currently rece…”
BackgroundInfluentialUse of Respimat� Soft Mist? Inhaler in COPD patients
ANDERSON, P. J. (2006) · International Journal of COPD · doi:10.2147/copd.2006.1.3.251 · Cited by 120 · cited 1×
“While the required inhalation technique is like that used with a pMDI, the aerosol is released very slowly from the device compared with an HFA-driven pMDI.(45) Dal Negro et al(46) compared T he ra pe ut ic s an d C lin ic al R is k M an ag em en t d ow nl oa de d fr om h ttp s: //w w w .”
MethodBraido, F., Chrystyn, H., Baiardini, I., Bosnic-Anticevich, S. Z., van der Molen, T., Dandurand, R. J., Chisholm, A., Carter, V. A., & Price, D. B. (2016) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2016.03.002 · Cited by 118
Interventions to improve inhaler technique for people with asthma
Normansell, R., Kew, K. M., & Mathioudakis, A. G. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012286.pub2 · Cited by 118
Westerik, J. A. M., Carter, V. A., Chrystyn, H., Burden, A., Thompson, S. L., Ryan, D. P., Gruffydd‐Jones, K., Haughney, J., Roche, N., Lavorini, F., et al. (2015) · Journal of Asthma · doi:10.3109/02770903.2015.1099160 · Cited by 111 · cited 1×
“However, a patient will require training and upskilling on any device,(15,52) and user technique should always be reviewed in patients with poor asthma control, even if they are using a device that is considered easy to use.(56) However, while training can enhance the ability to use inhalers, it has been reported that…”
BackgroundVincken, W., Dekhuijzen, R. P. N., & Barnes, P. J. (2009) · Primary Care Respiratory Journal · doi:10.4104/pcrj.2009.00062 · Cited by 110
Yawn, B. P., & Colice, G. (2012) · International Journal of COPD · doi:10.2147/copd.s32674 · Cited by 105 · cited 3×
“However, most nebulizer devices are generally bulky and inconvenient, require regular maintenance, prolong drug delivery from seconds to 10–15 minutes, and require regular thorough cleaning to sterilize the device.(27) It has been shown that in the acute management of disease, nebulizers produced outcomes that were no…”
BackgroundThe Digital Asthma Patient: The History and Future of Inhaler Based Health Monitoring Devices
Kikidis, D., Votis, K., Tzovaras, D. K., & Usmani, O. S. (2016) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2015.1267 · Cited by 101 · cited 2×
“In addition, weekly email reports are considered to help increase disease awareness, as well as to enhance understanding of treatment and preventative measures.(86) The approach, based on the global positioning system functionality of smartphones and available for the three main device types – pMDI, DPI, and Respimat…”
BackgroundSelf-citationDry powder inhalers in COPD, lung inflammation and pulmonary infections
Muralidharan, P., Hayes, D., & Mansour, H. M. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2015.977783 · Cited by 98 · cited 1×
“There are three main systems: capsule-based pre-metered singledose devices; multi-unit dose inhalers (preloaded by the manufacturer with a blister foil); and multiple-dose inhalers that employ an in-built mechanism that meters out a single dose with each actuation from a reservoir of powder.(38,39) Effective use of a…”
BackgroundJahedi, L., Downie, S. R., Saini, B., Chan, H., & Bosnic-Anticevich, S. Z. (2016) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2016.1287 · Cited by 92 · cited 2×
“In addition, most participants believed that a dose counter should be an integral part of an inhaler, while the need for proper training with a health care professional was also emphasized.(67) Patient preference for different inhaler types has been investigated in many studies.”
BackgroundMolimard, M., & Colthorpe, P. (2014) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2014.1142 · Cited by 88
Ari, A., & Fink, J. B. (2011) · Expert Review of Respiratory Medicine · doi:10.1586/ers.11.49 · Cited by 87
Levy, M. L., Dekhuijzen, P. N. R., Barnes, P. J., Broeders, M. E. A. C., Corrigan, C. J., Chawes, B., Corbetta, L., Dubus, J. ‐., Hausen, T., Lavorini, F., et al. (2016) · npj Primary Care Respiratory Medicine · doi:10.1038/npjpcrm.2016.17 · Cited by 86 · cited 2×
“While this has been solved by the addition of dose counters in many devices, the patient must be aware of the need to keep track of remaining medication.(36) Dry powder inhalers DPIs were introduced into clinical practice as user-friendly alternatives to CFC- and HFA-driven pMDIs.”
BackgroundSelf-citationUsmani, O. S. (2012) · Respiration · doi:10.1159/000343629 · Cited by 86
Self-citationPerspectives of patients and healthcare professionals on mHealth for asthma self-management
Simpson, A., Honkoop, P., Kennington, E. J., Snoeck-Stroband, J. B., Smith, I. P., East, J., Coleman, C., Caress, A., Chung, K. F., Sont, J. K., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.01966-2016 · Cited by 83 · cited 1×
“Digital health is a growing phenomenon, and offers the potential to help optimize patient care in several aspects of asthma management.(85) A selection of the digital and electronic options either available or under investigation are reviewed in detail elsewhere.”
BackgroundSelf-citationConsiderations for managing chronic obstructive pulmonary disease in the elderly
Taffet, G. E., Donohue, J. F., & Altman, P. (2013) · Clinical Interventions in Aging · doi:10.2147/cia.s52999 · Cited by 82 · cited 3×
“using nebulizers instead of other devices do so because of physical or cognitive disabilities.(26,27,29) However, most nebulizer devices are generally bulky and inconvenient, require regular maintenance, prolong drug delivery from seconds to 10–15 minutes, and require regular thorough cleaning to sterilize the device.”
BackgroundDifferences in medication adherence are associated with beliefs about medicines in asthma and COPD
Brandstetter, S., Finger, T., Fischer, W., Brandl, M., Böhmer, M. M., Pfeifer, M. A., & Apfelbacher, C. (2017) · Clinical and Translational Allergy · doi:10.1186/s13601-017-0175-6 · Cited by 75 · cited 1×
“Lack of adherence is an important health challenge, yet both asthma and COPD have lower adherence rates compared with other chronic conditions.(12) The detrimental impact of lack of adherence to COPD medication has been well documented by the TOwards a Revolution in COPD Health (TORCH) study, which found it to be sign…”
BackgroundInfluence of inhaler technique on asthma and COPD control: a multicenter experience
Ilic, A. D., Žugić, V., Zvezdin, B., Kopitović, I., Čekerevac, I., Ćupurdija, V., Perhoč, N., Veljkovic, V., & Barac, A. M. (2016) · International Journal of COPD · doi:10.2147/copd.s114576 · Cited by 71
Darbà, J., Ramírez, G., Martínez, P. F., Sicras‐Mainar, A., Torvinen, S., & la Rosa, R. S.-D. (2015) · International Journal of COPD · doi:10.2147/copd.s90155 · Cited by 65 · cited 2×
“Correct inhaler technique is important for optimal delivery of the drug to the lungs and peripheral airways, resulting in greater potential for the achievement of disease control.(36,57,60,61) As treatment efficacy is linked to adherence, addressing patient preferences are essential,(62) and tailored device selection…”
BackgroundInterventions to improve inhaler technique for people with asthma
Normansell, R., & Kew, K. M. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012286 · Cited by 61
Sonnappa, S., McQueen, B., Postma, D. S., Martin, R. J., Roche, N., Grigg, J., Guilbert, T. W., Gouder, C., Pizzichini, E., Niimi, A., et al. (2017) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2017.07.032 · Cited by 61 · cited 2×
“Preparations with extra-fine inhaled corticosteroids (ICS) have significantly higher odds of achieving asthma control, with lower exacerbation rates at significantly lower doses than fine-particle ICSs.(34) Patients stepping”
BackgroundSelf-citationAsthma Control: The Right Inhaler for the Right Patient
Scichilone, N. (2015) · Advances in Therapy · doi:10.1007/s12325-015-0201-9 · Cited by 59 · cited 1×
“As treatment efficacy is linked to adherence, addressing patient preferences are essential,(62) and tailored device selection can help enhance patient satisfaction, treatment adherence, and long-term outcomes.(22,62) Physical barriers that affect device handling are well documented.”
BackgroundPractical, regulatory and clinical considerations for development of inhalation drug products
Hou, S., Wu, J., Li, X., & Shu, H. (2015) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2015.08.008 · Cited by 58 · cited 1×
“To get FDA approval for a generic product, in vitro tests and in vivo equivalence studies are required, making it much harder to get approval.(84) Digital health is a growing phenomenon, and offers the potential to help optimize patient care in several aspects of asthma management.”
BackgroundCorrect inhalation technique is critical in achieving good asthma control
Lavorini, F., & Usmani, O. S. (2013) · Primary Care Respiratory Journal · doi:10.4104/pcrj.2013.00097 · Cited by 55 · cited 1×
“However, it is recognized that in addition to understanding the need to use an inhaler for disease control, patients must be educated on the necessity of using it properly.(25) Thus, from the patient perspective, it is likely that the choice of an inhalation device is often as important as the choice of treatment.”
BackgroundSelf-citationBasheti, I. A., Obeidat, N. M., & Reddel, H. K. (2017) · npj Primary Care Respiratory Medicine · doi:10.1038/s41533-017-0011-4 · Cited by 54
Sonnappa, S., Martin, R. J., Israel, E., Postma, D. S., van Aalderen, W. M. C., Burden, A., Usmani, O. S., Price, D. B., & on behalf of the Respiratory Effectiveness Group, S. A. S. G. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178112 · Cited by 41
Self-citationInhaled Aerosol Distribution in Human Airways: A Scintigraphy-Guided Study in a 3D Printed Model
Verbanck, S. A. B., Ghorbaniasl, G., Biddiscombe, M. F., Dragojlovic, D., Ricks, N., Lacor, C., Ilsen, B., Mey, J. D., Schuermans, D., Underwood, S. R., et al. (2016) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2016.1291 · Cited by 40
Self-citationA Review of Electronic Devices to Assess Inhaler Technique
Carpenter, D. M., Roberts, C. A., Sage, A., George, J., & Horne, R. (2017) · Current Allergy and Asthma Reports · doi:10.1007/s11882-017-0684-3 · Cited by 38 · cited 1×
“A selection of the digital and electronic options either available or under investigation are reviewed in detail elsewhere.(86,87) Briefly, one digital platform that has FDA approval (Propeller Health) aims to provide geospatial information on asthma attacks to help health care professionals identify exacerbation trig…”
BackgroundAsthma patients prefer Respimat® Soft Mist™ Inhaler to Turbuhaler®
Hodder, R. (2009) · International Journal of COPD · doi:10.2147/copd.s3452 · Cited by 37
Leung, J. M., Bhutani, M., Leigh, R., Pelletier, D., Good, C., & Sin, D. D. (2015) · Canadian Respiratory Journal · doi:10.1155/2015/731357 · Cited by 37
Efficacy and Safety of Tiotropium in Children and Adolescents
Hamelmann, E. H., & Szefler, S. J. (2018) · Drugs · doi:10.1007/s40265-018-0862-1 · Cited by 36
Opportunities for inhaler device selection in elderly patients with asthma or COPD
Barrons, R., Wheeler, J. S., & Woods, A. (2015) · Patient Intelligence · doi:10.2147/pi.s61200 · Cited by 17
Price, D. B., Colice, G., Israel, E., Roche, N., Postma, D. S., Guilbert, T. W., van Aalderen, W. M. C., Grigg, J., Hillyer, E. V., Thomas, V. M., et al. (2016) · ERJ Open Research · doi:10.1183/23120541.00106-2015 · Cited by 15 · cited 1×
“of multiple respiratory inhalers requiring different inhalation techniques has been shown to have an adverse effect on clinical outcomes in patients with COPD(23) and asthma.(24) Patients who believe using their inhaler is an important part of their asthma management demonstrate higher levels of correct inhaler use.”
BackgroundThe future of inhalers: how can we improve drug delivery in asthma and COPD?
Rogueda, P., & Traini, D. (2016) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2016.1227246 · Cited by 14
Bowles, S. K., SKETRIS, I. S., Kephart, G. C., & THEDRUGEVALUATIONALLIANCEOFN (2007) · The American Journal of Geriatric Pharmacotherapy · doi:10.1016/j.amjopharm.2007.05.003 · Cited by 6
Scichilone, N., Braido, F., Lavorini, F., Levy, M. L., & Usmani, O. S. (2017) · Drugs & Aging · doi:10.1007/s40266-017-0449-7 · Cited by 3
Self-citation
Metadata
- Authors
- Usmani, O. S.
- Venue
- Therapeutics and Clinical Risk Management
- Publisher
- Informa UK Limited
- Published
- 2019-03
- Volume
- Volume 15
- Pages
- 461-472
- ISSN
- 1176-6336 (ISSN-L)
- 1178-203X
- OpenAlex
- W2920976641
- Cited by
- 160
- References
- 62
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.