Removal of Arsenic from Groundwater using Crystalline Hydrous Ferric Oxide (CHFO)
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Synthesis of crystalline hydrous ferric oxide (CHFO), a modified iron-based adsorbent, and its arsenic sorption behaviour have been reported. Here, the effects of pH with variation of arsenic concentrations, contact time, pre-drying of CHFO, competition of some other anions and regeneration of arsenicsaturated CHFO are conducted by batch method. The sorption of As(V) is highly dependent on the concentration and pH of the experimental system, while that for As(III) is pH insensitive. As(III) is found to require less contact time to attain equilibrium than that of arsenic(V). Pre-drying of CHFO in the temperature range of 200 to 300°C is found to be effective in removing both As(III) and As(V). Adsorption kinetics follow the first-order Lagergren model. The equilibrium data conform to the Langmuir isotherm. Evaluated Langmuir constants and equilibrium parameter (RL) indicate that CHFO is a better As(III) adsorbent under experimental conditions. Sulphate, phosphate and bicarbonate compete poorly with As(III) sorption. A field test using CHFO-packed fixed-bed column is reported. Effluent water bed volumes of 14,000, 11,000 and 9000 BV (arsenic ≤ 0.01 mg L-1) were obtained in the first, second and third cycle of operation from a groundwater sample (arsenic content: 320.400 μg L-1). Regeneration of the exhausted column was achieved with up to 80 to 85% efficiency using 3 BV of 5 M NaOH solution recycled through the column five times. Arsenic was recovered as As2S3 from the regenerates, to avoid recycling of arsenic into the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Granular ferric hydroxide—a new adsorbent for the removal of arsenic from natural water
Driehaus, W., Jekel, M., & Hildebrandt, U. (1998) · Journal of Water Supply: Research and Technology—AQUA · doi:10.2166/aqua.1998.0005 · Cited by 341
Cited by
Arsenic removal from water/wastewater using adsorbents—A critical review
Mohan, D., & Pittman, C. U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.01.006 · Cited by 3,536
Arsenic contamination, consequences and remediation techniques: A review
Singh, R., Singh, S., Parihar, P., Singh, V. P., & Prasad, S. M. (2015) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2014.10.009 · Cited by 1,099
Jadhav, S. V., Bringas, E., Yadav, G. D., Rathod, V. K., Ortiz, I., & Marathe, K. V. (2015) · Journal of Environmental Management · doi:10.1016/j.jenvman.2015.07.020 · Cited by 596
Nanoadsorbents: Classification, Preparation, and Applications (with Emphasis on Aqueous Media)
Khajeh, M., Laurent, S., & Dastafkan, K. (2013) · Chemical Reviews · doi:10.1021/cr400086v · Cited by 528
Electrocoagulation applications for industrial wastewaters: a critical review
Kabdaşlı, I., Arslan-Alaton, I., Ölmez-Hancı, T., & Tünay, O. (2012) · Environmental Technology Reviews · doi:10.1080/21622515.2012.715390 · Cited by 384
Metadata
- Authors
- Manna, B. R., Dey, S., Debnath, S., & Ghosh, U. C.
- Venue
- Water Quality Research Journal
- Publisher
- IWA Publishing
- Published
- 2003-02-01
- Volume
- 38
- Issue
- 1
- Pages
- 193-210
- ISSN
- 1201-3080 (ISSN-L)
- 2408-9443
- OpenAlex
- W179841492
- Cited by
- 81
- References
- 1
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Removal of Arsenic from Groundwater using Crystalline Hydrous Ferric Oxide (CHFO). https://app.cochat.ai/papers/10.2166/wqrj.2003.013
- The paper
- Manna, B. R., Dey, S., Debnath, S., & Ghosh, U. C. (2003). Removal of Arsenic from Groundwater using Crystalline Hydrous Ferric Oxide (CHFO). Water Quality Research Journal. https://doi.org/10.2166/wqrj.2003.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.