The DOI matches its Crossref record.
The Hemostatic System
Abstract
The hemostatic system comprises platelet aggregation, coagulation and fibrinolysis also termed primary, secondary and tertiary hemostasis. From the platelet transcriptome 6000 mRNA species and represent receptors, ion channels, signalling molecules, kinases, phosphatases, and structural, metabolic and regulatory proteins. This abundance of regulatory proteins points towards the importance of signal transduction in platelet function. First platelets adhere to collagen, this induces activation signals such as TXA(2) that induces further Ca(2+) increase. Consecutively, fibrinogen binds to the integrin alpha(IIb)beta(3) resulting in aggregation.This self-amplifying process is controlled by signals, from endothelial cells, to restrict the platelet plug to the site of vessel injury. Secondary hemostasis (coagulation) consists of an extrinsic and intrinsic pathway. Thrombin is generated via Factor Xa resulting from the extrinsic tenase reaction that is turned of by tissue factor pathway inhibitor. While thrombin generation is maintained via positive feedback mechanisms activating factors V, VIII and XI. Excess thrombin is inhibited by antithrombin or by autodownregulation via activation of protein C. Since minor injuries are common, platelets and plasma clotting factors constantly produce clots to stop bleeding. If clots remained after the tissue healing, the vascular bed would become obstructed with clots therefore this is regulated by fibrinolysis, tertiary hemostasis. Tissue-type plasminogen activator synthesised by the endothelium, converts plasminogen to plasmin, the clot lysis enzyme. Plasmin clears the blood vessels by degrading fibrin. Fibrinolysis is controlled by plasminogen activators inhibitor (PAI-1), alpha2-antiplasmin and alpha2-macroglobulin, and thrombin-activatable fibrinolysis inhibitor (TAFI).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Complement and coagulation: strangers or partners in crime?
Markiewski, M. M., Nilsson, B., Nilsson Ekdahl, K., Mollnes, T. E., & Lambris, J. D. (2007) · Trends in Immunology · doi:10.1016/j.it.2007.02.006 · Cited by 645
Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007092 · Cited by 384
Bode, J. G., Albrecht, U., Häussinger, D., Heinrich, P. C., & Schaper, F. (2012) · European Journal of Cell Biology · doi:10.1016/j.ejcb.2011.09.008 · Cited by 379
The use of computational fluid dynamics in the development of ventricular assist devices
Fraser, K. H., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.10.014 · Cited by 278
Nano hemostat solution: immediate hemostasis at the nanoscale
Ellis-Behnke, R. G., Liang, Y.-X., Tay, D. K. C., Kau, P. W. F., Schneider, G. E., Zhang, S., Wu, W., & So, K.-F. (2006) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2006.08.001 · Cited by 269
Metadata
- Authors
- Stassen, J., Arnout, J., & Deckmyn, H.
- Venue
- Current Medicinal Chemistry
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2004-09-01
- Volume
- 11
- Issue
- 17
- Pages
- 2245-2260
- ISSN
- 0929-8673 (ISSN-L)
- OpenAlex
- W2114509436
- Cited by
- 181
- References
- 0
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Hemostatic System. https://app.cochat.ai/papers/10.2174/0929867043364603
- The paper
- Stassen, J., Arnout, J., & Deckmyn, H. (2004). The Hemostatic System. Current Medicinal Chemistry. https://doi.org/10.2174/0929867043364603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.