Protein Microarrays and Multiplexed Sandwich Immunoassays: What Beats the Beads?
The DOI matches its Crossref record.
Abstract
Protein microarray technology allows the simultaneous determination of a large variety of parameters from a minute amount of sample within a single experiment. Assay systems based on this technology are currently applied for the identification, quantitation and functional analysis of proteins. Protein microarray technology is of major interest for proteomic research in basic and applied biology as well as for diagnostic applications. Miniaturized and parallelized assay systems have reached adequate sensitivity and hence have the potential to replace singleplex analysis systems. However, robustness and automation needs to be demonstrated before this technology will finally prove suitable for high-throughput applications. Miniaturized and parallelized sandwich immunoassays are the most advanced assays formats among the different protein microarray applications. Multiplexed sandwich immunoassays can be used for the identification of biomarkers and the validation of potential target molecules. In this review an overview will be given on the current stage of protein microarray technology with a special focus on miniaturized multiplexed sandwich immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Waterboer, T., Sehr, P., Michael, K. M., Franceschi, S., Nieland, J. D., Joos, T. O., Templin, M. F., & Pawlita, M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052381 · Cited by 594
Self-citationLabel-free biomarker detection from whole blood
Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.353 · Cited by 543
Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges
Ellington, A. A., Kullo, I. J., Bailey, K. R., & Klee, G. G. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.127514 · Cited by 313
Protein microarrays for diagnostic assays
Hartmann, M., Roeraade, J., Stoll, D., Templin, M. F., & Joos, T. O. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2379-z · Cited by 173
Self-citationDiniz, B. S., Sibille, E., Ding, Y., Tseng, G., Aizenstein, H. J., Lotrich, F., Becker, J. T., Lopez, O. L., Lotze, M. T., Klunk, W. E., et al. (2015) · Molecular Psychiatry · doi:10.1038/mp.2014.76 · Cited by 116
Strathmann, F. G., Schulte, S., Goerl, K., & Petron, D. J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.01.028 · Cited by 98
“Suspension microsphere immunoassays are by far the more common design currently used for multiplexed antibody-based measurements [47] and are based upon the principles of flow cytometry.”
BackgroundEmerging affinity-based techniques in proteomics
Xie, S., Moya, C., Bilgin, B., Jayaraman, A., & Walton, S. P. (2009) · Expert Review of Proteomics · doi:10.1586/epr.09.74 · Cited by 38
Metadata
- Authors
- Templin, M., Stoll, D., Bachmann, J., & Joos, T.
- Venue
- Combinatorial Chemistry & High Throughput Screening
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2004-05-01
- Volume
- 7
- Issue
- 3
- Pages
- 223-229
- ISSN
- 1386-2073 (ISSN-L)
- OpenAlex
- W2023147819
- Cited by
- 68
- References
- 0
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.