Design and Development of Molecular Imaging Probes
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Molecular imaging, the visualization, characterization and measurement of biological processes at the cellular, subcellular level, or even molecular level in living subjects, has rapidly gained importance in the dawning era of personalized medicine. Molecular imaging takes advantage of the traditional diagnostic imaging techniques and introduces molecular imaging probes to determine the expression of indicative molecular markers at different stages of diseases and disorders. As a key component of molecular imaging, molecular imaging probe must be able to specifically reach the target of interest in vivo while retaining long enough to be detected. A desirable molecular imaging probe with clinical translation potential is expected to have unique characteristics. Therefore, design and development of molecular imaging probe is frequently a challenging endeavor for medicinal chemists. This review summarizes the general principles of molecular imaging probe design and some fundamental strategies of molecular imaging probe development with a number of illustrative examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The growing impact of click chemistry on drug discovery
Kolb, H. C., & Sharpless, K. B. (2003) · Drug Discovery Today · doi:10.1016/s1359-6446(03)02933-7 · Cited by 3,716 · cited 1×
“For example, “click chemistry” [87, 88] offers chemists a platform for general, modular and high yielding synthetic transformations for constructing highly diverse molecules.”
BackgroundQuantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216 · cited 4×
“Molecular imaging can provide a whole-body readout in an intact system, which is much more relevant and reliable than in vitro/ex vivo studies; decrease the workload and accelerate the drug development process; provide more statistically accurate results through longitudinal studies which can be performed in the same…”
BackgroundMethodInfluentialRhodes, D. R., Kalyana-Sundaram, S., Mahavisno, V., Varambally, R., Yu, J., Briggs, B. B., Barrette, T. R., Anstet, M. J., Kincead-Beal, C., Kulkarni, P., et al. (2007) · Neoplasia · doi:10.1593/neo.07112 · Cited by 2,060 · cited 3×
“gov/geo), ware-housing high-throughput microarray data of tumor expression profiles and bioinformatics initiatives, such as Oncomine [16,17], have been developed to accelerate the discovery of diagnostic markers for human diseases.”
MethodInfluentialA new type of synthetic peptide library for identifying ligand-binding activity
Lam, K. S., Salmon, S. E., Hersh, E. M., Hruby, V. J., Kazmierski, W. M., & Knapp, R. J. (1991) · Nature · doi:10.1038/354082a0 · Cited by 1,802
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
Prediction of Physicochemical Parameters by Atomic Contributions
Wildman, S. A., & Crippen, G. M. (1999) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci990307l · Cited by 1,464
Kwekkeboom, D. J., de Herder, W. W., Kam, B. L., van Eijck, C. H., van Essen, M., Kooij, P. P., Feelders, R. A., van Aken, M. O., & Krenning, E. P. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.2553 · Cited by 1,456
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Cited by
Nano based drug delivery systems: recent developments and future prospects
Patra, J. K., Das, G., Fraceto, L. F., Campos, E. V. R., Rodriguez-Torres, M. D. P., Acosta-Torres, L. S., Diaz-Torres, L. A., Grillo, R., Swamy, M. K., Sharma, S., et al. (2018) · Journal of Nanobiotechnology · doi:10.1186/s12951-018-0392-8 · Cited by 6,684
Inverse electron demand Diels–Alder reactions in chemical biology
Oliveira, B. L., Guo, Z., & Bernardes, G. J. L. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00184c · Cited by 1,139
Advances in drug delivery systems, challenges and future directions
Ezike, T. C., Okpala, U. S., Onoja, U. L., Nwike, C. P., Ezeako, E. C., Okpara, O. J., Okoroafor, C. C., Eze, S. C., Kalu, O. L., Odoh, E. C., et al. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e17488 · Cited by 1,040
Burggraaf, J., Kamerling, I. M. C., Gordon, P. B., Schrier, L., de Kam, M. L., Kales, A. J., Bendiksen, R., Indrevoll, B., Bjerke, R. M., Moestue, S. A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3641 · Cited by 299
In vivo fluorescence imaging: success in preclinical imaging paves the way for clinical applications
Refaat, A., Yap, M. L., Pietersz, G., Walsh, A. P. G., Zeller, J., del Rosal, B., Wang, X., & Peter, K. (2022) · Journal of Nanobiotechnology · doi:10.1186/s12951-022-01648-7 · Cited by 266
Radiolabeled Nanoparticles for Multimodality Tumor Imaging
Xing, Y., Zhao, J., Conti, P. S., & Chen, K. (2014) · Theranostics · doi:10.7150/thno.7341 · Cited by 234
“Molecular imaging can be defined as in vivo visualization, characterization and measurement of biological processes at the molecular and cellular levels [2, 3].”
BackgroundSelf-citationAntioxidant nanomaterials in advanced diagnoses and treatments of ischemia reperfusion injuries
Amani, H., Habibey, R., Hajmiresmail, S. J., Latifi, S., Pazoki-Toroudi, H., & Akhavan, O. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01689a · Cited by 219
Kobayashi, H., Longmire, M. R., Ogawa, M., & Choyke, P. L. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15077d · Cited by 216
Bai, J.-W., Qiu, S.-Q., & Zhang, G.-J. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01366-y · Cited by 210
“On the other hand, other modalities, such as photoacoustic imaging and MRI, can monitor the biological change associated with diseases either through the injection of exogenous molecular probes or by using endogenous molecules.(156) Tumor nonspecific imaging probes, such as (18)F-FDG for PET imaging and Tc-sulfur coll…”
BackgroundLossouarn, A., Renard, P.-Y., & Sabot, C. (2021) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.0c00568 · Cited by 26
Metadata
- Authors
- Chen, K., & Chen, X.
- Venue
- Current Topics in Medicinal Chemistry
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2010-08-01
- Volume
- 10
- Issue
- 12
- Pages
- 1227-1236
- ISSN
- 1568-0266 (ISSN-L)
- OpenAlex
- W1980427890
- Cited by
- 226
- References
- 71
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.