Comparison of FitBit® Ultra to ActiGraph™ GT1M for Assessment of Physical Activity in Young Adults During Treadmill Walking
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Introduction: Accelerometers are used to quantify energy expenditure in field research.The ActiGraph™ GT1M (ActiGraph™) is a commonly used accelerometer for research.The FitBit ® Ultra (FitBit ® ) is a low-cost alternative to the ActiGraph™; however, there is limited research on the validity of this device.Purpose: The pilot study compares the FitBit ® against the ActiGraph™ and metabolic cart for measurement of energy expenditure and step counts during treadmill walking.Methods: Thirty-two (25 female) adults, mean age 22±2 years, performed two thirty-minute phases of walking (slow and brisk) on a treadmill while concurrently wearing the FitBit ® and the ActiGraph™.Energy expenditure estimates were compared against energy expenditure measured by a metabolic cart.The Pearson's correlation and t-tests determine the linear association and similarity between the accelerometers.Results: Energy expenditure estimate is moderately correlated between the two accelerometers during slow walking (r=0.584,p=0.011) and strongly correlated during brisk walking (r=0.910,p<0.001).Step count is strongly correlated between the accelerometers during slow (r=0.974,p<0.001) and brisk (r=0.996,p<0.001) walking.The FitBit ® significantly underestimated energy expenditure during brisk walking compared to metabolic cart data.There is no difference between the slow and brisk phases' step counts using either accelerometer. Conclusion:The results of this pilot study suggest that the FitBit ® and the ActiGraph™ can be used interchangeably to measure steps, but not to measure kilocalories.Furthermore, the FitBit ® underestimates energy expenditure, compared to a metabolic cart, as exercise intensity increases.This limits its ability to accurately measure energy expenditure in active populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · cited 1×
“Monitoring physical activity is important for assessing activity patterns in populations being studied; however, even more important is the validity of the data being collected [5,6].”
Background
Cited by
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
“One study also reported entering stride length [34], another study input handedness and smoking status [35], and another study used event markers to denote when an activity started and ended [39].”
BackgroundMethodResultInfluentialFuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Wearable Performance Devices in Sports Medicine
Li, R. T., Kling, S. R., Salata, M. J., Cupp, S. A., Sheehan, J., & Voos, J. E. (2016) · Sports Health: A Multidisciplinary Approach · doi:10.1177/1941738115616917 · Cited by 348
Sushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152
Metadata
- Authors
- Gusmer, R. J., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R.
- Venue
- The Open Sports Medicine Journal
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2014-04-04
- Volume
- 8
- Issue
- 1
- Pages
- 11-15
- ISSN
- 1874-3870 (ISSN-L)
- OpenAlex
- W1985894314
- Cited by
- 59
- References
- 4
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of FitBit® Ultra to ActiGraph™ GT1M for Assessment of Physical Activity in Young Adults During Treadmill Walking. https://app.cochat.ai/papers/10.2174/1874387001408010011
- The paper
- Gusmer, R. J., Bosch, T. A., Watkins, A. N., Ostrem, J. D., & Dengel, D. R. (2014). Comparison of FitBit® Ultra to ActiGraph™ GT1M for Assessment of Physical Activity in Young Adults During Treadmill Walking. The Open Sports Medicine Journal. https://doi.org/10.2174/1874387001408010011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.