The biological width around implant
Open accessThe DOI matches its Crossref record; 129 of the 130 references it cites were found in a registry or an index.
Abstract
PURPOSE: The concept of biological width has been proposed and widely used in oral implantation. This review aimed to summarize the biological width around implant in detail. STUDY SELECTION: An electronic search of the literature prior to March 2019 was performed to identify all articles related to biological width in periimplant soft tissue. The search was conducted in the MEDLINE (National Library of Medicine) database accessed through PubMed with no date restriction. The following main keywords were used: "implant", "biological width", "soft tissue", "junctional epithelium", "peri-implant epithelium", "connective tissue", "gingiva", "mucosa" (connecting multiple keywords with AND, OR). RESULTS: The identified researches focused on several aspects related to biological width in oral implantation, namely the concept, formation, remodeling, dimension, structure and function. CONCLUSIONS: Based on of the reviewed literature, the concept, formation, remodeling, structure, dimension, and functional significances of periimplant biological width are explored in this narrative review. The formation of biological width around implant is a complex process after several weeks of healing. The biological width around implant is a 3-4mm distance from the top of the peri-implant mucosa to the first bone-to-implant contact or the stabilized top of the adjacent bone, consisting of sulcular epithelium, junctional epithelium and fibrous connective tissue between the epithelium and the first bone-to-implant contact or the stabilized top of the adjacent bone. The biological width forms a biological barrier against the bacteria, influences the remodeling of soft and hard tissue around implant and has implications for clinical aspects of dental implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Prostheses made and placed in an iatrogenic manner, i.e., violating the biological thickness, predispose an individual to the development of subgingival caries and result in an inflammatory process, which ultimately leads to the destruction of periodontal tissue [59,60].”
From Potential Impact of Prosthetic Biomaterials on the Periodontium: A Comprehensive Review (2023) · cites this paper as [59]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Negrí, B., Calvo‐Guirado, J. L., Fernández, M. P. R., de Val, J. E. M. S., Guardia, J., & Muñoz, F. M. G. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02290.x · Cited by 31
RetractedNegrí, B., Calvo‐Guirado, J. L., Zamora, G. P., Fernández, M. P. R., Ruiz, R. A. D., & Muñoz, F. M. G. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02158.x · Cited by 24
RetractedThe microbiota associated with successful or failing osseointegrated titanium implants
Mombelli, A., van Oosten, M. A. C., Schürch, E., & Lang, N. P. (1987) · Oral Microbiology and Immunology · doi:10.1111/j.1399-302x.1987.tb00298.x · Cited by 2,054
A simplified laminin nomenclature
AUMAILLEY, M., BRUCKNERTUDERMAN, L., CARTER, W., DEUTZMANN, R., EDGAR, D., EKBLOM, P., ENGEL, J., ENGVALL, E., HOHENESTER, E., & JONES, J. (2005) · Matrix Biology · doi:10.1016/j.matbio.2005.05.006 · Cited by 927
The soft tissue barrier at implants and teeth
Berglundh, T., Lindhe, J., Ericsson, I., Marinello, C. P., Liljenberg, B., & Thornsen, P. (1991) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1991.020206.x · Cited by 901
The Effect of Inter‐Implant Distance on the Height of Inter‐Implant Bone Crest
Tarnow, D. P., Cho, S. C., & Wallace, S. S. (2000) · Journal of Periodontology · doi:10.1902/jop.2000.71.4.546 · Cited by 880
Lazzara, R. J., & Porter, S. S. (2006) · PubMed · Cited by 852
Dimension of the periimplant mucosa: Biological width revisited
Berglundh, T., & Lindhe, J. (1996) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00520.x · Cited by 798
Dimensions of Peri‐Implant Mucosa: An Evaluation of Maxillary Anterior Single Implants in Humans
Kan, J. Y. K., Rungcharassaeng, K., Umezu, K., & Kois, J. C. (2003) · Journal of Periodontology · doi:10.1902/jop.2003.74.4.557 · Cited by 635
Structure and Function of Basement Membranes
LeBleu, V. S., MacDonald, B., & Kalluri, R. (2007) · Experimental Biology and Medicine · doi:10.3181/0703-mr-72 · Cited by 594
Research works printed but not linked: 15
- 1. Gargiulo AW, Wentz F, Orban B. Dimensions and relations of the dentogingival junction in humans. J Periodontol 1961;32:261-267.
- 75. de Oliveira GR, Olate S, Pozzer L, Cavalieri-Pereira L, Rodrigues-Chessa JG, Albergaría-Barbosa JR. Bacterial contamination along implant-abutment interface in external and internal-hex dental implants. Int J Clin Exp Med 2014;7:580-5.
- 77. Sorni-Broker M, Penarrocha-Diago M, Penarrocha-Diago M. Factors that influence the position of the peri-implant soft tissues: a review. Med Oral Patol Oral Cir Bucal 2009;14:e475-9.
- 121. Sugawara S, Maeno M, Lee C, et al. Establishment of epithelial attachment on titanium surface coated with platelet activating peptide. PLoS One 2016;11:e0164693.
- 122. Maeno M, Lee C, Kim DM, et al. Function of platelet-induced epithelial attachment at titanium surfaces inhibits microbial colonization. J Dent Res 2017;96:633-9.
- 123. Koidou VP, Argyris PP, Skoe EP, et al. Peptide coatings enhance keratinocyte attachment towards improving the peri-implant mucosal seal. Biomater Sci 2018;6:1936-45.
- 124. Zhang J, Wang H, Wang Y, et al. Substrate-mediated gene transduction of LAMA3 for promoting biological sealing between titanium surface and gingival epithelium. Colloids Surf B Biointerfaces 2018;161:314-23.
- 125. Abdulkareem EH, Memarzadeh K, Allaker RP, et al. Anti-biofilm activity of zinc oxide and hydroxyapatite nanoparticles as dental implant coating materials. J Dent 2015;43:1462-9.
- 126. Zhou L, Lai Y, Huang W, et al. Biofunctionalization of microgroove titanium surfaces with an antimicrobial peptide to enhance their bactericidal activity and cytocompatibility. Colloids Surf B Biointerfaces 2015;128:552-60.
- 127. Holmberg KV, Abdolhosseini M, Li Y, et al. Bio-inspired stable antimicrobial peptide coatings for dental applications. Acta Biomater 2013;9:8224-31.
- 128. Li T, Wang N, Chen S, et al. Antibacterial activity and cytocompatibility of an implant coating consisting of TiO2 nanotubes combined with a GL13K antimicrobial peptide. Int J Nanomedicine 2017;12:2995-3007.
- 129. Kihara H, Kim DM, Nagai M, et al. Epithelial cell adhesion efficacy of a novel peptide identified by panning on a smooth titanium surface. Int J Oral Sci 2018;10:21.
- 130. Mussano F, Genova T, Laurenti M, et al. Early response of fibroblasts and epithelial cells to pink-shaded anodized dental implant abutments: An In Vitro Study. Int J Oral Maxillofac Implants 2018;33:571-9.
- 131. Yang M, Jiang P, Ge Y, et al. Dopamine self-polymerized along with hydroxyapatite onto the preactivated titanium percutaneous implants surface to promote human gingival fibroblast behavior and antimicrobial activity for biological sealing. J Biomater Appl 2018;32:1071-82.
- 132. Teng F, Chen H, Xu Y, et al. Polydopamine deposition with anodic oxidation for better connective tissue attachment to transmucosal implants. J Periodontal Res 2018;53:222-31.
Cited by
Biomimetic materials based on zwitterionic polymers toward human-friendly medical devices
Ishihara, K. (2022) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2022.2119883 · Cited by 76
“undergo a healing process to repair this invasion and maintain life [25].”
BackgroundFiore, A. D., Montagner, M., Sivolella, S., Stellini, E., Yılmaz, B., & Brunello, G. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11164812 · Cited by 68
“Several factors are reported to be associated with crestal bone loss (CBL), including bacterial colonization and the presence of a micro-gap between abutment and implant [5,6].”
BackgroundRole of immune dysregulation in peri-implantitis
Huang, M., Wang, C., Li, P., Lu, H., Li, A., & Xu, S. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1466417 · Cited by 74
Potential Impact of Prosthetic Biomaterials on the Periodontium: A Comprehensive Review
Alarcón-Sánchez, M. A., Heboyan, A., Fernandes, G. V. D. O., Castro-Alarcón, N., & Romero-Castro, N. S. (2023) · Molecules · doi:10.3390/molecules28031075 · Cited by 52
“, violating the biological thickness, predispose an individual to the development of subgingival caries and result in an inflammatory process, which ultimately leads to the destruction of periodontal tissue [59,60].”
BackgroundLong-Term Clinical Outcomes of 3D-Printed Subperiosteal Titanium Implants: A 6-Year Follow-Up
Onică, N., Budală, D. G., Baciu, E.-R., Onică, C. A., Gelețu, G. L., Murariu, A. M., Balan, M., Perțea, M., & Stelea, C. G. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14050541 · Cited by 61
“However, a certain quantity and quality of bone are needed for its installation [5].”
BackgroundDynamic navigation guided surgery and prosthetics for immediate loading of complete‐arch restoration
Pozzi, A., Hansson, L. I., Carosi, P., & Arcuri, L. (2021) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.12710 · Cited by 46
Jin, S., Yu, Y., Zhang, T., Xie, D., Zheng, Y., Wang, C., Liu, Y., & Xia, D. (2024) · Bioactive Materials · doi:10.1016/j.bioactmat.2024.08.042 · Cited by 88
“Correspondingly, a dental implant depends on peri-implant junctional epithelium and connective tissue to form soft tissue seal [20], and directly contacts with bone to form osseointegration [3].”
BackgroundRíos-Osorio, N., Ladino, L. G., & Guerrero-Torres, M. (2025) · Journal of Periodontal & Implant Science · doi:10.5051/jpis.2402080104 · Cited by 42
“Their expression has also been analysed at the peri-implant tissue level [21,22].”
InfluentialJennes, M., Naumann, M., Peroz, S., Beuer, F., & Schmidt, F. (2021) · Antibiotics · doi:10.3390/antibiotics10111350 · Cited by 28
“It consists out of a sulcular epithelium, junctional epithelium and fibrous connective tissue between the epithelium and the first bone-to-implant contact [6].”
BackgroundQin, Z., Han, Y., Du, Y., Zhang, Y., Bian, Y., Wang, R., Wang, H., Guo, F., Yuan, H., Pan, Y., et al. (2024) · Science China Life Sciences · doi:10.1007/s11427-023-2454-9 · Cited by 27
“Deficient alveolar bone repair and regeneration may cause the failure of subsequent oral implantation, which gives rise to the medical and socioeconomic burden on patients (Zheng et al., 2021).”
An Injectable Black Phosphorus Hydrogel for Rapid Tooth Extraction Socket Healing
Guo, F., Li, J., Chen, Z., Wang, T., Wang, R., Wang, T., Bian, Y., Du, Y., Yuan, H., Pan, Y., et al. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c03278 · Cited by 26
Gehrke, S. A., Scarano, A., Cortellari, G. C., Fernandes, G. V. O., Mesquita, A. M. M., & Bianchini, M. A. (2023) · Journal of Functional Biomaterials · doi:10.3390/jfb14030128 · Cited by 21
“Other authors demonstrated that the biological width around an implant is 3–4 mm from the top of the peri-implant mucosa to the first bone-toimplant contact or the stabilized top of the adjacent bone [59].”
BackgroundD’Ambrosio, F., Caggiano, M., Chiacchio, A., Acerra, A., & Giordano, F. (2024) · Applied Sciences · doi:10.3390/app14135614 · Cited by 20
Impact of Implant Diameter on Success and Survival of Dental Implants: An Observational Cohort Study
Romanos, G. E., Schesni, A., Nentwig, G., Winter, A., Sader, R., & Brandt, S. (2023) · Prosthesis · doi:10.3390/prosthesis5030062 · Cited by 21
“In dental implantation, the aim is generally to achieve a sufficiently thick and stable amount of keratinized mucosa around the implant, to provide biological protection against bacteria [41].”
BackgroundHadzik, J., Kubasiewicz−Ross, P., Gębarowski, T., Waloszczyk, N., Maciej, A., Stolarczyk, A., Gedrange, T., Dominiak, M., Szajna, E., & Simka, W. (2023) · Journal of Functional Biomaterials · doi:10.3390/jfb14010034 · Cited by 17
“Differences in microscopic featuring, and especially in fibroblast distribution, seem to influence the strength of the peri-implant soft tissue junction and result, among other things, in a different biological width of the soft tissue surrounding the implant [7].”
BackgroundTang, P., Meng, Z., Song, X., Huang, J., Su, C., & Li, L. (2023) · Clinical Oral Investigations · doi:10.1007/s00784-023-04902-w · Cited by 16
“1 3 contact, usually measured as 3–4 mm [43].”
BackgroundChen, H., Yan, J., Hu, S., Sun, S., Zhou, F., Liu, J., Tang, S., Zhou, Q., Ding, H., Zhang, F., et al. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.111083 · Cited by 15
Zhang, L., Zhou, C. D., Jiang, J., Chen, X., Wang, Y., Xu, A., & He, F. (2024) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13947 · Cited by 13
Jia, S., Zhao, H., Song, Y., Sun, Y. J., Wang, G., & Wang, X. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500025 · Cited by 13
Wang, M.-F., Yan, T., Gao, M., Han, C.-W., Yan, Z., Gao, Y., Zhang, W., & Yi, Z. (2025) · Biomedical Materials · doi:10.1088/1748-605x/adca7c · Cited by 15
“However, soft tissue closure is less robust around implants than around natural teeth, primarily due to the absence of periodontal fibers [215].”
Wang, R., Wang, T., Chen, Z., Jiang, J., Du, Y., Yuan, H., Pan, Y., & Wang, Y. (2025) · Science China Life Sciences · doi:10.1007/s11427-024-2745-2 · Cited by 10
“Alveolar bone deficiency may cause delay or failure of subsequent oral implantation, thereby leading to severe waiting-time problems and socioeconomic burden on patients (Zheng et al., 2021).”
Burgoa, S. M., Costa, A. J. D. M. E., Ventura, D., Pinhata-Baptista, O. H., & Cortes, A. R. G. (2022) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2022.05.032 · Cited by 10
Zandinejad, A., Khurana, S., Liang, Y., & Liu, X. (2023) · Journal of Prosthodontics · doi:10.1111/jopr.13650 · Cited by 10
Sun, Y., Yang, J., Chen, K., Li, Z., Chen, Z., & Huang, B. (2023) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.13230 · Cited by 10
Ma, S., Du, Y., Xu, S., Li, M., Lu, X., Tian, G., Ye, J., Zhao, B., Liu, Z.-H., Wei, P., et al. (2023) · iScience · doi:10.1016/j.isci.2023.108212 · Cited by 8
Sakar, D., Güncü, M. B., Kalayci, H. A., Muhtaroğulları, M., Aktaş, G., Reiss, N., & Türkyilmaz, I. (2023) · Journal of Dental Sciences · doi:10.1016/j.jds.2023.11.001 · Cited by 8
“4,5 However, due to the weaker attachment between soft tissue and implants, comparable to that of free gingiva, there is a higher risk of soft tissue collapse under stress.”
BackgroundElkabany, A. H., Hakim, A. A. A., Mahmoud, S., & Gaweesh, Y. Y. (2024) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2024.06.022 · Cited by 6
Effect of the TIM-3/Gal-9 signaling pathway on macrophage polarization in peri-implantitis
Cheng, L., Dong, S., Ni, X.-F., Long, M., He, J.-G., Mamat, A., & Gong, Z. (2025) · PLoS ONE · doi:10.1371/journal.pone.0328258 · Cited by 7
“Notably, due to ethical considerations and the critical role of health-associated peri-implant gingival tissue in maintaining implant success and preventing inflammation-related complications [30–32], we did not obtain peri-implant tissues from individuals with healthy implants.”
Aellos, F., Clavelier, A., Liu, B., Wan, A., Salvi, G. E., Romandini, M., & Helms, J. A. (2026) · Journal of Periodontal Research · doi:10.1111/jre.70091 · Cited by 6
Hao, Y., Shi, C., ZHANG, Y., Zou, R., Dong, S., Chuncheng, Y. A. N. G., & Niu, L. (2024) · Dental Materials Journal · doi:10.4012/dmj.2024-076 · Cited by 8
Lee, S.-J., Kim, E.-H., Lee, D., Song, I., & Jun, S.-H. (2022) · International Journal of Implant Dentistry · doi:10.1186/s40729-022-00442-2 · Cited by 7
“Although there are some differences between biological width of natural tooth and of dental implant, their functions and importance are similar [25].”
BackgroundYan, Y., Yan, Q., Cai, K., Wang, Z., Li, Q., Zhao, K., Jian, Y., & Jia, X. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101158 · Cited by 7
“Additionally, the connective tissue near abutments contains lower concentration of type I and type III collagen, an elevated level of type V collagen, and reduced fibroblasts, which leads to a marked decrease in tissue repair capabilities after inflammation [9].”
BackgroundPosessor, A. D., Badalyan, V., & Vasilyev, A. V. (2024) · Stomatology · doi:10.17116/stomat202410306229 · Cited by 5
Won, C. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14072435 · Cited by 9
The Role of Caspase-11 and Pyroptosis in the Regulation of Inflammation in Peri-Implantitis
Jiao, P., Li, Z., Li, B., & Jiao, X. (2023) · Journal of Inflammation Research · doi:10.2147/jir.s427523 · Cited by 6
“20 Due to microbial pressure in oral and potential rejection of foreign bodies (generally Ti particles), the peri-implant soft tissue may be in a mild inflammatory-healthy alternation for a long time.”
BackgroundCasaponsa, J., Vinothkumar, T. S., Dummer, P. M. H., Nagendrababu, V., & Sans, F. A. (2024) · Journal of Endodontics · doi:10.1016/j.joen.2024.02.017 · Cited by 5
“Indeed, margins of restorations often lie deep within the gingival sulcus that will violate the supracrestal tissue attachment (STA) 2 often referred to as the biological width 3,4 .”
Treatment Planning for Single-Tooth Implant: A Clinical Guide and Literature Review
Gadicherla, S., Singh, A., & Kudva, A. (2025) · Journal of Maxillofacial and Oral Surgery · doi:10.1007/s12663-025-02631-z · Cited by 4
Ho, K., Shiba, T., Chen, C., & Kim, D. M. (2025) · Biomimetics · doi:10.3390/biomimetics10090571 · Cited by 4
“When the seal is fragile or absent, the supporting structure around implants is more prone to inflammation and increases the risk of developing peri-implant disease [17].”
Bridging Gaps in Oral Mucosa Regeneration: Advances and Challenges
Liu, Z., Wang, S., Yang, S., Liu, W., Huo, N., Xu, J., Shi, Q., & Liu, H. (2025) · Tissue Engineering Part B Reviews · doi:10.1177/19373368251405708 · Cited by 4
Vaghela, J., Moufti, M. A., Seoudi, N., & Kheder, W. (2024) · Dentistry Review · doi:10.1016/j.dentre.2024.100085 · Cited by 4
Biological Width around One- and Two-piece Implants: A Systematic Review
Srivastava, S., Kalburgi, V., Banerjee, N., Tripathi, B., Jain, M., & Singh, S. (2024) · Journal of Head & Neck Physicians and Surgeons · doi:10.4103/jhnps.jhnps_45_24 · Cited by 4
Docampo-Vázquez, C., Gragera-Alia, T., Fernández‐Domínguez, M., Zubizarreta‐Macho, Á., & Aragoneses, J. M. (2024) · Frontiers in Dental Medicine · doi:10.3389/fdmed.2024.1372312 · Cited by 3
Labadi, C., Gauthier, R., Trunfio-Sfarghiu, A.-M., Abouelleil, H., Lafon, A., & Attik, N. (2026) · Dental Materials · doi:10.1016/j.dental.2026.06.004 · Cited by 3
Zheng, Z., Ao, X., Xie, P., Xiao, Z., Lee, K., & Chen, W. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00895 · Cited by 3
Self-citationBruyn, H. D., Pivovarova, M., Rondas, A., Scheldeman, M., de Laak, H. O., & Vandeweghe, S. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14217699 · Cited by 2
“Crestal bone loss around implants occurs during initial healing as a consequence of a physiological process rather than a sign of disease [19].”
Prosthetic Management of Peri-Implant Mucositis via CRD Optimization: A Split-Mouth Case Report
Won, C. (2025) · Prosthesis · doi:10.3390/prosthesis7060146 · Cited by 2
“Thus, a deeper understanding of the peri-implant–soft tissue interface is vital for improving outcomes and preventing complications [6].”
Clinical decision-making of anterior implant abutment.
Yu, H., Sun, M., & Wang, Z. (2022) · PubMed Central · doi:10.7518/hxkq.2022.05.002 · Cited by 1
Zaccheo, F., Petroni, G., Tallarico, M., Gioga, C., Carletti, R., Gioia, C. R. T. D., Petrozza, V., Meloni, S. M., Melodia, D., Pisano, M., et al. (2025) · Dentistry Journal · doi:10.3390/dj13040154 · Cited by 1
“The characteristics of the peri-implant mucosa are determined during the biological width establishment that occurs following several weeks of healing after connecting the healing abutments or prosthetic components [2,3].”
InfluentialCeddia, M., Romasco, T., Pietro, N. D., Lamberti, L., & Trentadue, B. (2026) · Journal of Functional Biomaterials · doi:10.3390/jfb17050208 · Cited by 1
“In particular, reduced spacing has been associated with greater marginal bone loss, and sites with an IID of less than 3 mm generally show more crestal bone resorption than those with an IID of 3 mm or more [17–21].”
Universidad Anáhuac Cancún, C., Hernandez, J., Baroi, A. M., Vasiliu, M. P., Tomiţa, D. I., Cucoveica, O., Albert, C., & Stadoleanu, C. (2025) · Romanian Journal of Oral Rehabilitation · doi:10.62610/rjor.2025.2.17.95 · Cited by 2
Gaggi, G., Credico, A. D., D’Addazio, G., Ghinassi, B., Argentieri, G., Caputi, S., Baldassarre, A. D., & Sinjari, B. (2023) · BMC Oral Health · doi:10.1186/s12903-023-03148-y · Cited by 1
“Inflammation or infection of the soft tissues can lead to the loss of surrounding bone, ultimately resulting in implant failure [1].”
BackgroundFrontiers in the Understanding of Peri-Implant Disease
Perez, A., & Lombardi, T. (2025) · Dentistry · doi:10.5772/intechopen.1011935 · Cited by 1
Potapchuk, A. M., Алмаші, В. М., Onipko, Y. L., Rak, Y. V., & Melnyk, Y. O. (2023) · Інновації в стоматології · doi:10.35220/2523-420x/2023.2.5 · Cited by 1
Rubertis, C. D. (2022) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2022.45.007218
Tamimi, S., & Mandour, M. H. E.-D. (2023) · Tanta Dental Journal · doi:10.4103/tdj.tdj_71_22
Li, L., Liu, H., Chen, J., Zhang, Z., Xiao, S., Zhang, L., & Wang, Y. (2023) · PubMed Central · doi:10.7518/hxkq.2023.2023089
Maintenance of Full-Arch Implant-Supported Restorations: Peri-Implant and Prosthetic Considerations
Kumar, S., Kar, K., & Jivraj, S. (2023) · BDJ clinician's guides · doi:10.1007/978-3-031-32847-3_19
Костенко, Є. Я., & Бойчук, М. М. (2023) · Інновації в стоматології · doi:10.35220/2523-420x/2023.4.7
Dental Implant Fractures: A Report of 43 Implant Fixtures in 33 Patients
Park, S.-J., & Ahn, K. (2024) · Journal of implantology and applied sciences · doi:10.32542/implantology.2024001
Frauches, V. D. M. S., Almeida, E. C. D., & Heggendorn, F. L. (2024) · International journal of odontostomatology · doi:10.4067/s0718-381x2024000100100
Marković, J. M., Todorovic, A., Ilić, B., Aleksa, M., Zivanovic, T., Veljković, K., & Milinković, I. (2024) · Vojnosanitetski pregled · doi:10.2298/vsp231226045m
“The integrity of the peri-implant supracrestal attachment depends on the good condition of the sulcular epithelium, the impermeability of the junctional epithelium, and the elasticity of the connective tissue 2 .”
Nano recubrimiento de óxido de grafeno sobre aditamentos protésicos de titanio
Martínez, N. C. C., Aguilar, V. M., Tapia, I. A. N., Chimal, R. Á., & Vázquez-Vázquez, F. C. (2025) · Mundo Nano Revista Interdisciplinaria en Nanociencia y Nanotecnología · doi:10.22201/ceiich.24485691e.2025.34.69827
Mousa, M. A., Alshubrmi, H. R., Issrani, R., & Alzarea, B. K. (2024) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2024.16.6.336
Casaponsa, J., Vinothkumar, T. S., Narasimhan, B., Dummer, P. M. H., Nagendrababu, V., & Sans, F. A. (2025) · Australian Endodontic Journal · doi:10.1111/aej.12927
Zhao, Y., Liu, Q., Qiu, L., Hao, J., Su, H. H., & Su, Y. (2025) · Materials Technology · doi:10.1080/10667857.2025.2492587
“Differences in the distribution of fibroblasts appear to affect the strength of the peri-implant soft tissue connections and lead to different biological widths of the peri-implant soft tissue [35].”
Introduction, History and General Principles
Deporter, D. A., Baldi, D., & Ketabi, M. (2025) · Wiley eBooks · doi:10.1002/9781394187133.ch1
Rethinking Mechanical Overload in Dental Implants
Hooshiar, M. H. (2025) · Springer eBooks · doi:10.1007/978-3-031-36962-9_350-1
Song, Z., Yu, X., & Luan, Q. (2025) · Research Square · doi:10.21203/rs.3.rs-8203136/v1
Yang, Y., Su, W., & Liu, X. (2026) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s573116
“4 However, research indicates that optimized glycemic control and appropriate perioperative management can significantly mitigate these risks, with well-controlled diabetic patients achieving implant success rates approaching those of non-diabetic individuals.”
Hooshiar, M. H. (2025) · Springer eBooks · doi:10.1007/978-3-031-36962-9_344-1
Awareness and Usage of Water Irrigation Devices Among Implant Patients: A Cross‐Sectional Study
Jamjoom, A. (2026) · International Journal of Dental Hygiene · doi:10.1111/idh.70029
Effect of implant neck design on peri-implant tissue conditions: a narrative review
Xie, Z., Sammour, S. R., Ogawa, T., & Yoda, N. (2026) · International Journal of Implant Dentistry · doi:10.1186/s40729-026-00683-5
“Berglundh et al. proposed that biological width existed around implants [80], conceptualized as a dimen-sion of approximately 3–4 mm from the top of the peri-implant mucosa to the first bone-to-implant contact, acting as a protective barrier for peri-implant tissues [81].”
Xie, B., Gloßner, I., Mündt, T., Heinemann, F., & Dörsam, I. (2026) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2026.152850
Chen, Y., Ding, J., Xu, Z., Guo, W., Liu, Y., Chen, J., Wu, D., & Zhou, L. (2026) · Clinical Oral Implants Research · doi:10.1111/clr.70145
Basic and Principles of Periodontal and Implant Anatomy
Kazemian, M., Mauer, R. G., & Mehdizadeh, S. (2025) · Springer eBooks · doi:10.1007/978-3-031-36962-9_48-1
Barraco, A., Gustin, M., Noël, G., Grosgogeat, B., & Lafon, A. (2026) · International Journal of Dentistry · doi:10.1155/ijod/5542019
Vertical ridge augmentation and implant rehabilitation: a case report
Spears, K. (2026) · Dental Update · doi:10.12968/denu.2026.53.sup2.s60
Pieniak, O., & Górski, B. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15176784
“Supracrestal Tissue Height and the Soft-Tissue–Bone Interface STH is the vertical soft-tissue compartment between the alveolar crest and mucosal margin and provides a conceptual link between soft tissues and crestal remodeling [8,9,15].”
Dual‐Targeted Biomimetic MoSe 2 Nanozymes for Enhancing Peri‐Implant Soft Tissue Integration
Zhou, M., Tian, M., Yu, J., Kang, J., Chen, M., Yuan, Y., Liu, L., & Wei, H. (2026) · Advanced Science · doi:10.1002/advs.77771
“In contrast, collagen I accumulates during the remodeling phase, forming a denser and mechanically stronger fibrillar network that contributes to stable connective tissue attachment and enhances the integrity of the soft tissue seal [ 63, 64 ].”
Erfan, O., & Taka, G. (2026) · The Open Dentistry Journal · doi:10.2174/01187421062869261002103439
Saberian, E., Jenča, A., Zare‐Zardini, H., Jenča, A., Petrášová, A., Jenčová, J., & Wieckiewicz, M. A. (2026) · Dental and Medical Problems · doi:10.17219/dmp/211027
Yim, Y., Lim, S., Yi, Y., Wi, S., Park, B., & Kim, H. (2026) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2026.18.5.448
Favagehi, M., Christopher, L. A., Huang, P., & Sabounchi, S. S. (2026) · Dentistry Review · doi:10.1016/j.dentre.2026.100443
Metadata
- Authors
- Zheng, Z., Ao, X., Xie, P., Jiang, F., & Chen, W.
- Affiliations
- State Key Laboratory of Oral Diseases (CN)
- Affiliated Hospital of North Sichuan Medical College (CN)
- Venue
- Journal of Prosthodontic Research
- Publisher
- Japan Prosthodontic Society
- Published
- 2021
- Volume
- 65
- Issue
- 1
- Pages
- 11-18
- ISSN
- 1883-1958 (ISSN-L)
- 1883-9207
- OpenAlex
- W3084237727
- Semantic Scholar
- c80228bef7d0da72daa28a4cb27c39899a41d09a
- Cited by
- 84
- References
- 129
- Citations by year
- 2026: 15 · 2025: 21 · 2024: 21 · 2023: 16 · 2022: 8 · 2021: 3
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Journal of Prosthodontic Research (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Sichuan University
- Topics
- Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
- Health Sciences › Dentistry › Periodontics › Oral microbiology and periodontitis research
- Health Sciences › Dentistry › Periodontics › Periodontal Regeneration and Treatments
- Keywords
- biological width, dental implants, peri-implant soft tissue, junctional epithelium, connective tissue, sulcular epithelium, bone-implant contact, gingiva
- MeSH terms
- Connective Tissue, Dental Implantation, Endosseous, Epithelial Attachment, Gingiva, Wound Healing, Dental Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.