Glycemic Outcomes in Adults With Type 2 Diabetes Participating in a Continuous Glucose Monitor–Driven Virtual Diabetes Clinic: Prospective Trial
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: The Onduo virtual diabetes clinic (VDC) for people with type 2 diabetes (T2D) combines a mobile app, remote personalized lifestyle coaching, connected devices, and live video consultations with board-certified endocrinologists for medication management and prescription of real-time continuous glucose monitoring (RT-CGM) devices for intermittent use. Objective: This prospective single-arm study evaluated glycemic outcomes associated with participation in the Onduo VDC for 4 months. Methods: Adults aged ≥18 years with T2D and a baseline glycated hemoglobin (HbA1c) of ≥8% to ≤12% were enrolled from 2 primary care centers from February 2019 to October 2019. Participants were asked to engage at ≥1 time per week with their care team and to participate in a telemedicine consultation with a clinic endocrinologist for diabetes medication review. Participants were asked to use a RT-CGM device and wear six 10-day sensors (total 60 days of sensor wear) intermittently over the course of 4 months. The primary outcome was change in HbA1c at 4 months from baseline. Other endpoints included change in weight and in RT-CGM glycemic metrics, including percent time <70, 70-180, 181-250, and >250 mg/dL. Changes in blood pressure and serum lipids at 4 months were also evaluated. Results: Participants (n=55) were 57.3 (SD 11.6) years of age, body mass index 33.7 (SD 7.2), and 40% (22/55) female. HbA1c decreased significantly by 1.6% (SD 1%; P<.001). When stratified by baseline HbA1c of 8.0% to 9.0% (n=36) and >9.0% (n=19), HbA1c decreased by 1.2% (SD 0.6%; P<.001) and 2.4% (SD 1.3%; P<.001), respectively. Continuous glucose monitoring–measured (n=43) percent time in range (TIR) 70-180 mg/dL increased by 10.2% (SD 20.5%; P=.002), from 65.4% (SD 23.2%) to 75.5% (SD 22.7%), which was equivalent to a mean increase of 2.4 hours TIR per day. Percent time 181-250 mg/dL and >250 mg/dL decreased by 7.2% (SD 15.4; P=.005) and 3.0% (SD 9.4; P=.01), respectively. There was no change in percent time <70 mg/dL. Mean weight decreased by 9.0 lb (SD 10.4; P<.001). Significant improvements were also observed in systolic blood pressure, total cholesterol, low-density lipoprotein cholesterol, and triglycerides (P=.04 to P=<.001). Conclusions: Participants in the Onduo VDC experienced significant improvement in HbA1c, increased TIR, decreased time in hyperglycemia, and no increase in hypoglycemia at 4 months. Improvements in other metabolic health parameters including weight and blood pressure were also observed. In conclusion, the Onduo VDC has potential to support people with T2D and their clinicians between office visits by increasing access to specialty care and advanced diabetes technology including RT-CGM. Trial Registration: ClinicalTrials.gov NCT03865381; https://clinicaltrials.gov/ct2/show/NCT03865381
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“4 hours per day—is considered a clinically meaningful increase [17].”
BackgroundQuinn, C. C., Shardell, M. D., Terrin, M. L., Barr, E. A., Ballew, S. H., & Gruber-Baldini, A. L. (2011) · Diabetes Care · doi:10.2337/dc11-0366 · Cited by 650
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Hallberg, S. J., McKenzie, A. L., Williams, P. T., Bhanpuri, N. H., Peters, A. L., Campbell, W. W., Hazbun, T. L., Volk, B. M., McCarter, J. P., Phinney, S. D., et al. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0373-9 · Cited by 406
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199 · cited 10×
“During the 40-week follow-up period, RCT participants did not use RT-CGM, yet durable improvement in HbA1c was observed at the 52-week follow-up assessment in the RT-CGM group compared with the self-monitoring blood glucose group.”
BackgroundMethodResultInfluentialRunge, A. S., Kennedy, L., Brown, A. S., Dove, A. E., Levine, B. J., Koontz, S. P., Iyengar, V. S., Odeh, S. A., Close, K. L., Hirsch, I. B., et al. (2018) · Clinical Diabetes · doi:10.2337/cd17-0094 · Cited by 87
A virtual type 2 diabetes clinic using continuous glucose monitoring and endocrinology visits
Dixon, R. F., Zisser, H., Layne, J. E., Barleen, N. A., Miller, D. P., Moloney, D. P., Majithia, A. R., Gabbay, R. A., & Riff, J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819888662 · Cited by 80
Self-citation
Cited by
Continuous glucose monitoring for the routine care of type 2 diabetes mellitus
Ajjan, R. A., Battelino, T., Cos, X., Del Prato, S., Philips, J.-C., Meyer, L., Seufert, J., & Seidu, S. (2024) · Nature Reviews Endocrinology · doi:10.1038/s41574-024-00973-1 · Cited by 117
“…of people with type 2 diabetes mellitus (T2DM) using CGM have been tested in real-life settings; for example the Onduo Virtual Diabetes Clinic 188,203,204 , which is associated with a statistically significant improvement in HbA 1c and with reduced diabetes mellitus distress, compared with…”
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
“This will likely remain an important tool in maximizing patient access options and improving communication with providers.(25,26,56) Another developing application of rtCGM relevant to both T1D and T2D is use in the inpatient setting, where frequent monitoring with remote display may show significant advantages in nur…”
MethodGrace, T., & Salyer, J. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0212 · Cited by 64
Comprehensive Telehealth Model to Support Diabetes Self-Management
Aleppo, G., Gal, R. L., Raghinaru, D., Kruger, D., Beck, R. W., Bergenstal, R. M., Cushman, T., Hood, K. K., Johnson, M. L., McArthur, T., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.36876 · Cited by 42
Identifying the deficiencies of currently available CGM to improve uptake and benefit
Barnard‐Kelly, K. D., Martínez‐Brocca, M. A., Glatzer, T., & Oliver, N. (2024) · Diabetic Medicine · doi:10.1111/dme.15338 · Cited by 37
Metadata
- Authors
- Majithia, A. R., Kusiak, C. M., Armento Lee, A., Colangelo, F. R., Romanelli, R. J., Robertson, S., Miller, D. P., Erani, D. M., Layne, J. E., Dixon, R. F., & Zisser, H.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2020-08-28
- Volume
- 22
- Issue
- 8
- Pages
- e21778
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W3044099509
- Cited by
- 58
- References
- 7
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.